Novel Pharyngeal Oxygen Delivery Device Provides Superior Oxygenation during Simulated Cardiopulmonary Resuscitation

被引:0
|
作者
Hanson, Jeramie B. [1 ,2 ]
Williams, John R. [2 ,3 ]
Garmon, Emily H. [1 ,2 ]
Morris, Phillip M. [1 ,2 ]
Mcallister, Russell K. [1 ,2 ]
Culp Jr, William C. [1 ,2 ]
机构
[1] Baylor Coll Med, Temple, TX USA
[2] Baylor Scott & White Med Ctr, Temple Dept Anesthesiol, Temple, TX USA
[3] Texas A&M Sch Med, Temple, TX USA
关键词
Advanced Cardiac Life Support; cardiopulmonary resuscitation; passive oxygenation; pharyngeal oxygen delivery device; supraglottic airway; CHEST COMPRESSIONS; CARDIAC-ARREST; ASSOCIATION; INTERRUPTIONS; DECOMPRESSION; INSUFFLATION; VENTILATION; SURVIVAL; EFFICACY;
D O I
10.1017/S1049023X24000542
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Passive oxygenation with non-rebreather face mask (NRFM) has been used during cardiac arrest as an alternative to positive pressure ventilation (PPV) with bag-valve- mask (BVM) to minimize chest compression disruptions. A dual-channel pharyngeal oxygen delivery device (PODD) was created to open obstructed upper airways and provide oxygen at the glottic opening. It was hypothesized for this study that the PODD can deliver oxygen as efficiently as BVM or NRFM and oropharyngeal airway (OPA) in a cardiopulmonary resuscitation (CPR) manikin model. Methods: Oxygen concentration was measured in test lungs within a resuscitation manikin. These lungs were modified to mimic physiologic volumes, expansion, collapse, and recoil. Automated compressions were administered. Five trials were performed for each of five arms: (1) CPR with 30:2 compression-to-ventilation ratio using BVM with 15 liters per minute (LPM) oxygen; continuous compressions with passive oxygenation using (2) NRFM and OPA with 15 LPM oxygen, (3) PODD with 10 LPM oxygen, (4) PODD with 15 LPM oxygen; and (5) control arm with compressions only. Results: Mean peak oxygen concentrations were: (1) 30:2 CPR with BVM 49.3% (SD = 2.6%); (2) NRFM 47.7% (SD = 0. 2%); (3) PODD with 10 LPM oxygen 52.3% (SD = 0.4%); (4) PODD with 15 LPM oxygen 62.7% (SD = 0. 3%); and (5) control 21% (SD = 0%). Oxygen concentrations rose rapidly and remained steady with passive oxygenation, unlike 30:2 CPR with BVM, which rose after each ventilation and decreased until the next ventilation cycle (sawtooth pattern, mean concentration 40% [SD = 3%]). Conclusions: Continuous compressions and passive oxygenation with the PODD resulted in higher lung oxygen concentrations than NRFM and BVM while minimizing CPR interruptions in a manikin model.
引用
收藏
页码:354 / 357
页数:4
相关论文
共 50 条
  • [21] CONJUNCTIVAL OXYGEN MONITORING DURING CARDIOPULMONARY RESUSCITATION
    JAMES, MR
    ARCHIVES OF EMERGENCY MEDICINE, 1989, 6 (04): : 286 - 286
  • [22] CONJUNCTIVAL OXYGEN MONITORING DURING CARDIOPULMONARY RESUSCITATION
    HEYWORTH, J
    ARCHIVES OF EMERGENCY MEDICINE, 1989, 6 (02): : 128 - 136
  • [23] Cerebral oximetry provides early warning of oxygen delivery failure during cardiopulmonary bypass
    Prabhune, A
    Sehic, A
    Spence, PA
    Church, T
    Edmonds, HL
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (02) : 204 - 206
  • [24] A RANDOMIZED CONTROLLED TRIAL OF PHARYNGEAL COOLING SYSTEM DURING CARDIOPULMONARY RESUSCITATION
    Takeda, Y.
    Shiraishi, K.
    Naito, H.
    Morimoto, N.
    Morita, K.
    INTENSIVE CARE MEDICINE, 2009, 35 : 143 - 143
  • [25] Cerebral oxygenation during cardiopulmonary resuscitation with epinephrine and vasopressin in pigs
    Prengel, AW
    Lindner, KH
    Keller, A
    STROKE, 1996, 27 (07) : 1241 - 1247
  • [26] The use of 100% compared to 50% oxygen during ineffective experimental cardiopulmonary resuscitation improves brain oxygenation
    Nelskyla, Annika
    Humaloja, Jaana
    Litonius, Erik
    Pekkarinen, Pirkka
    Babini, Giovanni
    Maki-Aho, Tomi P.
    Heinonen, Juho A.
    Skrifvars, Markus B.
    RESUSCITATION, 2023, 182
  • [27] A pilot study of mechanical chest compression with the LifeLine ARM device during simulated cardiopulmonary resuscitation: Reply
    Cotte, Jean
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2017, 36 (04) : 251 - 251
  • [28] Ventilatory device effectiveness during cardiopulmonary resuscitation (CPR)
    Dörges, V
    Ocker, H
    Schmucker, P
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 : 72 - 72
  • [29] Mechanisms for generating improved hemodynamics with a novel chest compression device during cardiopulmonary resuscitation
    Halperin, H
    Paradis, N
    Zviman, M
    Ornato, J
    Leng, C
    Lardo, A
    Kern, K
    CIRCULATION, 2004, 110 (17) : 342 - 343
  • [30] CORRELATION OF TRANSCONJUNCTIVAL PO2 WITH CEREBRAL OXYGEN DELIVERY DURING CARDIOPULMONARY RESUSCITATION IN DOGS
    GUERCI, AD
    THOMAS, K
    HESS, D
    HALPERIN, HR
    TSITLIK, JE
    WURMB, E
    EITEL, D
    CRITICAL CARE MEDICINE, 1988, 16 (06) : 612 - 614