Valve Performance Between Latest-Generation Balloon-Expandable and Self-Expandable Transcatheter Heart Valves in a Small Aortic Annulus

被引:0
|
作者
Hioki, Hirofumi [1 ]
Yamamoto, Masanori [2 ,3 ,4 ]
Shirai, Shinichi [5 ]
Ohno, Yohei [6 ]
Yashima, Fumiaki [7 ]
Naganuma, Toru [8 ]
Yamawaki, Masahiro [9 ]
Watanabe, Yusuke [10 ]
Yamanaka, Futoshi [11 ]
Mizutani, Kazuki [12 ]
Ryuzaki, Toshinobu [13 ]
Noguchi, Masahiko [14 ]
Izumo, Masaki [15 ]
Takagi, Kensuke [16 ]
Asami, Masahiko [17 ]
Ueno, Hiroshi [18 ]
Nishina, Hidetaka [19 ]
Otsuka, Toshiaki [20 ,21 ]
Suzuyama, Hiroto [22 ]
Yamasaki, Kazumasa [23 ]
Nishioka, Kenji [24 ]
Hachinohe, Daisuke [25 ]
Fuku, Yasushi [26 ]
Hayashida, Kentaro [13 ]
机构
[1] IMS Tokyo Katsushika Gen Hosp, Dept Gastroenterol, 1-18-1 Nishi-Shinkoiwa,Katsushika Ku, Tokyo 1240025, Japan
[2] Toyohashi Heart Ctr, Dept Cardiol, 21-1 Gobutgori,Oyamacho, Toyohashi, Aichi 4418530, Japan
[3] Nagoya Heart Ctr, Dept Cardiol, Nagoya, Japan
[4] Gifu Heart Ctr, Dept Cardiol, Gifu, Japan
[5] Kokura Mem Hosp, Dept Cardiol, Kokura, Japan
[6] Tokai Univ, Sch Med, Dept Cardiol, Isehara, Japan
[7] Saiseikai Utsunomiya Hosp, Dept Cardiol, Tochigi, Japan
[8] New Tokyo Hosp, Dept Cardiol, Matsudo, Japan
[9] Saiseikai Yokohama City Eastern Hosp, Dept Cardiol, Tsurumi, Kanagawa, Japan
[10] Teikyo Univ Hosp, Div Cardiol, Tokyo, Japan
[11] Shonan Kamakura Gen Hosp, Dept Cardiol, Kamakura, Japan
[12] Kinki Univ, Dept Cardiol, Osaka, Japan
[13] Keio Univ, Sch Med, Div Cardiol, Tokyo, Japan
[14] Tokyo Bay Urayasu Ichikawa Med Ctr, Dept Cardiol, Urayasu, Japan
[15] St Marianna Univ, Sch Med, Dept Cardiol, Kawasaki, Japan
[16] Natl Cerebral & Cardiovasc Ctr, Dept Cardiol, Osaka, Japan
[17] Mitsui Mem Hosp, Div Cardiol, Tokyo, Japan
[18] Toyama Univ, Dept Pediat, Toyama 9300194, Japan
[19] Tsukuba Med Ctr Hosp, Dept Cardiol, Tsukuba, Japan
[20] Nippon Med Sch, Dept Hyg & Publ Hlth, Tokyo, Japan
[21] Nippon Med Sch, Ctr Clin Res, Tokyo, Japan
[22] Saiseikai Kumamoto Hosp, Dept Cardiol, Kumamoto, Japan
[23] Sapporo Higashi Tokushukai Hosp, Dept Cardiol, Sapporo, Hokkaido, Japan
[24] Hiroshima City Hiroshima Citizens Hosp, Dept Cardiol, Hiroshima, Japan
[25] Sapporo Cardio Vasc Clin, Dept Cardiovasc Med, Sapporo, Japan
[26] Kurashiki Cent Hosp, Dept Cardiol, Okayama, Japan
关键词
balloon-expandable valve; self-expandable valve; small aortic annulus; transcatheter aortic valve replacement; valve performance; CLINICAL-OUTCOMES; IMPLANTATION; REPLACEMENT; IMPACT; PREDICTORS; VS;
D O I
10.1016/j.jcin.2024.08.049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Transcatheter aortic valve replacement (TAVR) using a self-expandable valve (SEV) promotes better hemodynamics compared with a balloon-expandable valve (BEV) in a small aortic annulus (SAA). OBJECTIVES The authors sought to compare hemodynamic properties and clinical outcomes between the latest- generation BEV and SEV after TAVR for SAA. METHODS We retrospectively analyzed 1,227 patients undergoing TAVR for aortic stenosis with SAA, defined as an annulus area <= 430 mm2, using the BEV (SAPIEN3 Ultra RESILIA, Edwards Lifesciences) and SEV (Evolut FX, Medtronic). The impact of valve design on severe prosthesis-patient mismatch, aortic valve mean pressure gradient >= 20 mm Hg, paravalvular leakage (PVL) >= mild, new permanent pacemaker implantation (PMI), and modified VARC-3 device success at discharge was evaluated using logistic regression and propensity score analysis. RESULTS Of 1,227 patients, 798 (65.0%) underwent TAVR with BEV implantation. TAVR using BEV had a relatively higher rate of severe prosthesis-patient mismatch (OR: 1.74; 95% CI: 0.54-5.62) and significantly higher incidence of mean pressure gradient >= 20 mm Hg (OR: 2.05; 95% CI: 0.91-4.62) than that using SEV. By contrast, the BEV showed significantly lower incidence of PVL >= mild (OR: 0.19; 95% CI: 0.14-0.26), and new PMI (OR: 0.53; 95% CI: 0.33-0.86). The rate of device success was comparable between the BEV and the SEV. These results were confirmed by propensity score analysis. CONCLUSIONS In TAVR for SAA, SEV demonstrated better hemodynamics than the latest BEV, whereas the latest BEV had lower incidences of PVL >= mild and new PMI than the SEV. (JACC Cardiovasc Interv. 2024;17:2612-2622) (c) 2024 by the American College of Cardiology Foundation.
引用
收藏
页码:2612 / 2622
页数:11
相关论文
共 50 条
  • [31] Balloon-expandable versus Self-expandable Transcatheter Aortic Valve Prostheses: Comparison of periinterventional Outcomes
    Kuntscher, A.
    Lassnig, E.
    Porodko, M.
    Srndic, E.
    Geissler, H. K.
    Binder, R. K.
    WIENER KLINISCHE WOCHENSCHRIFT, 2023, 135 : S391 - S391
  • [32] Differences in Pressure Recovery Between Balloon Expandable and Self-expandable Transcatheter Aortic Valves
    Hatoum, Hoda
    Hahn, Rebecca T.
    Lilly, Scott
    Dasi, Lakshmi Prasad
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (02) : 860 - 867
  • [33] Differences in Pressure Recovery Between Balloon Expandable and Self-expandable Transcatheter Aortic Valves
    Hoda Hatoum
    Rebecca T. Hahn
    Scott Lilly
    Lakshmi Prasad Dasi
    Annals of Biomedical Engineering, 2020, 48 : 860 - 867
  • [34] Multicenter comparison of latest-generation balloon-expandable versus self-expanding transcatheter heart valves: Ultra versus Evolut
    Rheude, Tobias
    Pellegrini, Costanza
    Allali, Abdelhakim
    Bleiziffer, Sabine
    Kim, Won-Keun
    Neuser, Jonas
    Landt, Martin
    Rudolph, Tanja
    Renker, Matthias
    Widder, Julian D.
    Qu, Lailai
    Alvarez-Covarrubias, Hector A.
    Mayr, N. Patrick
    Richardt, Gert
    Xhepa, Erion
    Joner, Michael
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2022, 357 : 115 - 120
  • [35] Combination Use of Inoue-Balloon and Self-Expandable Transcatheter Valves in Managing Aortic Stenosis Not Amenable to Balloon-Expandable Valves
    Saji, Mike
    Highchi, Ryosuke
    Iguchi, Nobuo
    Takamisawa, Itaru
    Shimizu, Jun
    Shimokawa, Tomoki
    Nanasato, Mamoru
    Takayama, Morimasa
    Isobe, Mitsuaki
    INTERNATIONAL HEART JOURNAL, 2022, 63 (05) : 843 - 851
  • [36] Overexpansion of Balloon-Expandable Aortic Transcatheter Heart Valves in the Mitral Valve Position
    Al-Hijji, Mohammed
    Eleid, Mackram
    Wang, Dee Dee
    Kodali, Susheel
    Kaptzan, Tatiana
    El Sabbagh, Abdallah
    Oh, Jae
    O'Neill, William
    Rihal, Chet
    Guerrero, Mayra
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B149 - B150
  • [37] Evaluation of Acquired Thrombocytopenia According to the Balloon-Expandable Versus Self-Expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement
    Kisacik, Halil
    Tok, Derya
    Balci, Kevser Gulcihan
    Demirkan, Burcu
    Karakurt, Mustafa
    Acar, Burak
    Karabulut, Ozlem
    Erbay, Ilke
    Balci, Mustafa Mucahit
    ANGIOLOGY, 2021, 72 (03) : 290 - 294
  • [38] REPLY: Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves CHOICE Trial Results
    Abdel-Wahab, Mohamed
    Richardt, Gert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (02) : 236 - 237
  • [39] AORTIC ANGULATION ATTENUATES PROCEDURAL SUCCESS FOLLOWING SELF-EXPANDABLE BUT NOT BALLOON-EXPANDABLE TRANSCATHETER AORTIC VALVE IMPLANTATION
    Abramowitz, Yigal
    Maeno, Yoshio
    Chakravarty, Tarun
    Mangat, Geeteshwar
    Kazuno, Yoshio
    Takahashi, Nobuyuki
    Kawamori, Hiroyuki
    Nakamura, Mamoo
    Cheng, Wen
    Jilaihawi, Hasan
    Makkar, Raj
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1666 - 1666
  • [40] Prosthesis-Patient Mismatch After Transcatheter Implantation of Contemporary Balloon-Expandable and Self-Expandable Valves in Small Aortic Annuli
    Leone, Pier Pasquale
    Regazzoli, Damiano
    Cannata, Francesco
    Pagnesi, Matteo
    Barbanti, Marco
    de Cruz, Hospital
    Adamo, Marianna
    Taramasso, Maurizio
    De Marco, Federico
    Mangieri, Antonio
    Giannini, Francesco
    Ohno, Yohei
    Saia, Francesco
    Ielasi, Alfonso
    Pighi, Michele
    Ribichini, Flavio
    Maffeo, Diego
    Stefanini, Giulio
    Bedogni, Francesco
    Kim, Won-Keun
    Maisano, Francesco
    Tamburino, Corrado
    Van Mieghem, Nicolas
    Colombo, Antonio
    Reimers, Bernhard
    Latib, Azeem
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B203 - B203