In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper Next and TruNatomy Endodontic Rotary Files

被引:0
|
作者
Ramteke, Payal [1 ]
Prajapati, Mitulkumar R. [2 ]
Vashisth, Diwakar [3 ]
Aga, Nausheen [4 ]
Mohanty, Rajat [5 ]
Chougule, Prajakta G. [6 ]
Hassan, Muna E. M. [7 ]
机构
[1] Govt Med Coll, Dept Dent, Nagpur, Maharashtra, India
[2] Ahmedabad Dent Coll & Hosp, Dept Oral Pathol & Microbiol, Ahmadabad, Gujarat, India
[3] Lady Hardinge Med Coll & Hosp, Dept Dent & Oral Surg, New Delhi, India
[4] Univ Dundee, Sch Dent, Dundee, Scotland
[5] KIIT Deemed Be Univ, Kalinga Inst Dent Sci, Dept Oral & Maxillofacial Surg, Bhubaneswar, Odisha, India
[6] Bharati Vidyapeeth Deemed Be Univ Dent Coll & Hos, Dept Conservat Dent & Endodont, Sangli, Maharashtra, India
[7] Univ Sharjah, Dept Prevent & Restorat Dent, Sharjah, U Arab Emirates
关键词
Cyclic fatigue resistance (CFR); endodontic files; ProTaper Next; TruNatomy; NICKEL-TITANIUM INSTRUMENTS;
D O I
10.4103/jpbs.jpbs_107_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: The purpose of this comparative in vitro study was to investigate the cyclic fatigue resistance (CFR) of two different rotary endodontic file systems, namely, TruNatomy and ProTaper Next filing systems. Material and Methods: A stainless steel artificial canal with a 60 degrees curvature angle and a 5 mm radius of curvature was used to simulate clinical settings to carry out the test. Twenty ProTaper Next X2 files and 20 TruNatomy Prime files were used to run a total of forty instruments until a fracture occurred, and the amount of time it took for the fracture to occur was taken into account. The files were driven by an endodontic motor set when the settings were adjusted according to the manufacturer's recommendations. A digital meter was employed to record the duration until fracture occurrence, thus ensuring precision. Results: The TruNatomy files had a larger mean cycle fatigue life, which indicates that they have a higher resistance. Conclusions: Given the constraints of this in vitro testing, the CFR of TruNatomy files was found to be significantly higher than that of ProTaper Next files.
引用
收藏
页码:S2126 / S2128
页数:3
相关论文
共 50 条
  • [41] Effect of two different temperatures on resistance to cyclic fatigue of one Curve, EdgeFile, HyFlex CM and ProTaper next files
    Topcuoglu, Huseyin Sinan
    Topcuoglu, Gamze
    Kafdag, Ozgur
    Balkaya, Hacer
    AUSTRALIAN ENDODONTIC JOURNAL, 2020, 46 (01) : 68 - 72
  • [42] Shot peening increases resistance to cyclic fatigue fracture of endodontic files
    Nino-Barrera, Javier
    Sanchez-Aleman, Jose
    Acosta-Humanez, Manuel
    Gamboa-Martinez, Luis
    Cortes-Rodriguez, Carlos
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [43] Shot peening increases resistance to cyclic fatigue fracture of endodontic files
    Javier Nino-Barrera
    Jose Sanchez-Aleman
    Manuel Acosta-Humanez
    Luis Gamboa-Martinez
    Carlos Cortes-Rodriguez
    Scientific Reports, 11
  • [44] Differences in Cyclic Fatigue Resistance between ProTaper Next and ProTaper Universal Instruments at Different Levels
    Perez-Higueras, Juan J.
    Arias, Ana
    de la Macorra, Jose C.
    Peters, Ove A.
    JOURNAL OF ENDODONTICS, 2014, 40 (09) : 1477 - 1481
  • [45] Effects of Autoclave Sterilization on Cyclic Fatigue Resistance in 5 Types of Rotary Endodontic Instruments: An In Vitro Study
    Stoaic, Nenad
    Popovic, Jelena
    Apostolovic, Marija Andelkovic
    Mitic, Aleksandar
    Nikolic, Marija
    Barac, Radomir
    Kostic, Milena
    MEDICAL SCIENCE MONITOR, 2023, 29
  • [46] Assessment of cyclic fatigue resistance of Protaper Next and WaveOne Gold in different kinematics
    Amira Galal Ismail
    Manar Galal
    Nehal Nabil Roshdy
    Bulletin of the National Research Centre, 44 (1)
  • [47] Flexural Fatigue of Unicone, Navigator Evo and Protaper Next Files in Reciprocate and Continuous Rotary Systems in Simulated Curved Canals-An In Vitro Study
    Alqahtani, Saeed
    Al-Omari, Mohammad
    Olarinmoye, Ayodeji Oluwadare
    Alrahlah, Ali
    METALS, 2020, 10 (01)
  • [48] Dynamic cyclic and torsional fatigue resistance of TruNatomy compared with different nickel-titanium rotary instruments
    Elnaghy, Amr M.
    Elsaka, Shaymaa E.
    Elshazli, Alaa H.
    AUSTRALIAN ENDODONTIC JOURNAL, 2020, 46 (02) : 226 - 233
  • [49] The influence of cyclic straining in torsion on fatigue resistance and torsional properties of ProTaper NiTi endodontic instruments
    Martins, Renata de Castro
    Bahia, Maria Guiomar Azevedo
    Buono, Vicente Tadeu Lopes
    FUNCTIONAL AND STRUCTURAL MATERIALS, 2010, 643 : 79 - +
  • [50] Assessment of the Mechanical Properties of ProTaper Next Nickel-Titanium Rotary Files
    Elnaghy, Amr M.
    Elsaka, Shaymaa E.
    JOURNAL OF ENDODONTICS, 2014, 40 (11) : 1830 - 1834