In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper Next and TruNatomy Endodontic Rotary Files

被引:0
|
作者
Ramteke, Payal [1 ]
Prajapati, Mitulkumar R. [2 ]
Vashisth, Diwakar [3 ]
Aga, Nausheen [4 ]
Mohanty, Rajat [5 ]
Chougule, Prajakta G. [6 ]
Hassan, Muna E. M. [7 ]
机构
[1] Govt Med Coll, Dept Dent, Nagpur, Maharashtra, India
[2] Ahmedabad Dent Coll & Hosp, Dept Oral Pathol & Microbiol, Ahmadabad, Gujarat, India
[3] Lady Hardinge Med Coll & Hosp, Dept Dent & Oral Surg, New Delhi, India
[4] Univ Dundee, Sch Dent, Dundee, Scotland
[5] KIIT Deemed Be Univ, Kalinga Inst Dent Sci, Dept Oral & Maxillofacial Surg, Bhubaneswar, Odisha, India
[6] Bharati Vidyapeeth Deemed Be Univ Dent Coll & Hos, Dept Conservat Dent & Endodont, Sangli, Maharashtra, India
[7] Univ Sharjah, Dept Prevent & Restorat Dent, Sharjah, U Arab Emirates
关键词
Cyclic fatigue resistance (CFR); endodontic files; ProTaper Next; TruNatomy; NICKEL-TITANIUM INSTRUMENTS;
D O I
10.4103/jpbs.jpbs_107_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: The purpose of this comparative in vitro study was to investigate the cyclic fatigue resistance (CFR) of two different rotary endodontic file systems, namely, TruNatomy and ProTaper Next filing systems. Material and Methods: A stainless steel artificial canal with a 60 degrees curvature angle and a 5 mm radius of curvature was used to simulate clinical settings to carry out the test. Twenty ProTaper Next X2 files and 20 TruNatomy Prime files were used to run a total of forty instruments until a fracture occurred, and the amount of time it took for the fracture to occur was taken into account. The files were driven by an endodontic motor set when the settings were adjusted according to the manufacturer's recommendations. A digital meter was employed to record the duration until fracture occurrence, thus ensuring precision. Results: The TruNatomy files had a larger mean cycle fatigue life, which indicates that they have a higher resistance. Conclusions: Given the constraints of this in vitro testing, the CFR of TruNatomy files was found to be significantly higher than that of ProTaper Next files.
引用
收藏
页码:S2126 / S2128
页数:3
相关论文
共 50 条
  • [31] An in vitro comparison of apically extruded bacteria with ProTaper Gold, ProTaper Universal and ProTaper Next rotary systems
    Bag, Irem
    Kurnaz, Safa
    Gulbandilar, Aysel
    ENDO-ENDODONTIC PRACTICE TODAY, 2020, 14 (04): : 281 - 286
  • [32] A Comparative Examination of Cyclic Fatigue and Fragment Length of Three Different Types of Endodontic Rotary Files: An In Vitro Study
    Saleh, Hanaa Abduljabbar
    Abdulhameed, Othman Husham
    DENTAL HYPOTHESES, 2022, 13 (02): : 49 - 52
  • [33] Evaluation of the cyclic fatigue resistance of 2Shape, ProTaper Gold and Vortex Blue rotary NiTi files in curved canals: a comparative in vitro study
    El Mankabadi, Sarah Isaac
    Ahmed, Geraldine Mohamed
    ElAsfouri, Heba Ahmed
    ENDO-ENDODONTIC PRACTICE TODAY, 2020, 14 (04): : 297 - 304
  • [34] The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
    Faus-Llacer, Vicente
    Kharrat, Nirmine Hamoud
    Ruiz-Sanchez, Celia
    Faus-Matoses, Ignacio
    Zubizarreta-Macho, Alvaro
    Faus-Matoses, Vicente
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 14
  • [35] Resistance to Cyclic Fatigue Failure of a New Endodontic Rotary File
    Bouska, Jason
    Justman, Bruce
    Williamson, Anne
    DeLong, Christopher
    Qian, Fang
    JOURNAL OF ENDODONTICS, 2012, 38 (05) : 667 - 669
  • [36] In vitro comparison of cyclic fatigue resistance of two rotary single-file endodontic systems: OneCurve versus OneShape
    Marco Serafin
    Matteo De Biasi
    Vittorio Franco
    Daniele Angerame
    Odontology, 2019, 107 : 196 - 201
  • [37] In vitro comparison of cyclic fatigue resistance of two rotary single-file endodontic systems: OneCurve versus OneShape
    Serafin, Marco
    De Biasi, Matteo
    Franco, Vittorio
    Angerame, Daniele
    ODONTOLOGY, 2019, 107 (02) : 196 - 201
  • [38] The Cyclic Fatigue Resistance of Different Lengths of CM Gold Wire and CM Blue Wire NiTi Alloy Endodontic Rotary Files: An In Vitro Study
    Faus-Matoses, Vicente
    Faus-Llacer, Vicente
    Ruiz-Sanchez, Celia
    Prats Gallego, Sofia
    Zubizarreta-Macho, Alvaro
    Solano-Mendoza, Beatriz
    Biedma, Benjamin Martin
    Faus-Matoses, Ignacio
    APPLIED SCIENCES-BASEL, 2023, 13 (07):
  • [39] Effects of Chitosan, NaOCl, and EDTA Irrigation Solutions on the Cyclic Fatigue Resistance of Three Nickel-Titanium Endodontic Rotary Files: An In Vitro Study
    Salloom, Wisam S.
    Shukri, Biland M. S.
    DENTAL HYPOTHESES, 2022, 13 (04): : 121 - 123
  • [40] Variations in cyclic fatigue resistance among ProTaper Gold, ProTaper Next and ProTaper Universal instruments at different levels
    Uygun, A. D.
    Kol, E.
    Topcu, M. K. C.
    Seckin, F.
    Ersoy, I.
    Tanriver, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (05) : 494 - 499