In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper Next and TruNatomy Endodontic Rotary Files

被引:0
|
作者
Ramteke, Payal [1 ]
Prajapati, Mitulkumar R. [2 ]
Vashisth, Diwakar [3 ]
Aga, Nausheen [4 ]
Mohanty, Rajat [5 ]
Chougule, Prajakta G. [6 ]
Hassan, Muna E. M. [7 ]
机构
[1] Govt Med Coll, Dept Dent, Nagpur, Maharashtra, India
[2] Ahmedabad Dent Coll & Hosp, Dept Oral Pathol & Microbiol, Ahmadabad, Gujarat, India
[3] Lady Hardinge Med Coll & Hosp, Dept Dent & Oral Surg, New Delhi, India
[4] Univ Dundee, Sch Dent, Dundee, Scotland
[5] KIIT Deemed Be Univ, Kalinga Inst Dent Sci, Dept Oral & Maxillofacial Surg, Bhubaneswar, Odisha, India
[6] Bharati Vidyapeeth Deemed Be Univ Dent Coll & Hos, Dept Conservat Dent & Endodont, Sangli, Maharashtra, India
[7] Univ Sharjah, Dept Prevent & Restorat Dent, Sharjah, U Arab Emirates
关键词
Cyclic fatigue resistance (CFR); endodontic files; ProTaper Next; TruNatomy; NICKEL-TITANIUM INSTRUMENTS;
D O I
10.4103/jpbs.jpbs_107_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: The purpose of this comparative in vitro study was to investigate the cyclic fatigue resistance (CFR) of two different rotary endodontic file systems, namely, TruNatomy and ProTaper Next filing systems. Material and Methods: A stainless steel artificial canal with a 60 degrees curvature angle and a 5 mm radius of curvature was used to simulate clinical settings to carry out the test. Twenty ProTaper Next X2 files and 20 TruNatomy Prime files were used to run a total of forty instruments until a fracture occurred, and the amount of time it took for the fracture to occur was taken into account. The files were driven by an endodontic motor set when the settings were adjusted according to the manufacturer's recommendations. A digital meter was employed to record the duration until fracture occurrence, thus ensuring precision. Results: The TruNatomy files had a larger mean cycle fatigue life, which indicates that they have a higher resistance. Conclusions: Given the constraints of this in vitro testing, the CFR of TruNatomy files was found to be significantly higher than that of ProTaper Next files.
引用
收藏
页码:S2126 / S2128
页数:3
相关论文
共 50 条
  • [1] Cyclic Fatigue Comparison of TruNatomy, Twisted File, and ProTaper Next Rotary Systems
    Riyahi, Abdullah Mahmoud
    Bashiri, Amr
    Alshahrani, Khalid
    Alshahrani, Saad
    Alamri, Hadi M.
    Al-Sudani, Dina
    INTERNATIONAL JOURNAL OF DENTISTRY, 2020, 2020
  • [2] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files
    Lee, S. W.
    Park, Y. G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (11) : 1100 - 1100
  • [3] Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files
    Elnaghy, A. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (11) : 1034 - 1039
  • [4] Cyclic Fatigue Resistance of ProTaper Next and NRT Nickel Titanium Rotary Files
    Elbatouty, Kariem Mostafa
    Elbatal, Laila M.
    Obeid, Maram Mohamed
    ENDO-ENDODONTIC PRACTICE TODAY, 2016, 10 (02): : 89 - 94
  • [5] In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper, WaveOne, and Twisted Files
    Castello-Escriva, Ricardo
    Alegre-Domingo, Teresa
    Faus-Matoses, Vicente
    Roman-Richon, Sophie
    Faus-Llacer, Vicente J.
    JOURNAL OF ENDODONTICS, 2012, 38 (11) : 1521 - 1524
  • [6] Cyclic fatigue resistance of EdgeTaper Platinum, Protaper Gold, and TruNatomy Prime rotary files before and after autoclave sterilization
    Almohareb, Rahaf A.
    Barakat, Reem M.
    Algahtani, Fahda N.
    Alkadi, Manal F.
    PEERJ, 2023, 11
  • [7] Influence of Temperature on Cyclic Fatigue Resistance of ProTaper Gold and ProTaper Universal Rotary Files
    Plotino, Gianluca
    Grande, Nicola M.
    Mercado Bellido, Montse
    Testarelli, Luca
    Gambarini, Gianluca
    JOURNAL OF ENDODONTICS, 2017, 43 (02) : 200 - 202
  • [8] Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files
    Gouedard, Charlotte
    Pino, Laurent
    Arbab-Chirani, Reza
    Arbab-Chirani, Shabnam
    Chevalier, Valerie
    RESTORATIVE DENTISTRY AND ENDODONTICS, 2022, 47 (02):
  • [9] Comparison of the fracture resistance of the teeth prepared with ProTaper Universal, ProTaper Next, and ProTaper Gold rotary files
    Milani, Amin Salem
    Ganjpour, Shabnam
    Dehghani, Fatemeh
    Rahimi, Saeed
    Sabanik, Pouya
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2022, 8 (06): : 1421 - 1425
  • [10] An in vitro comparison of cyclic fatigue resistance of ProTaper universal and GT series X files
    Montenegro-Santillan, Ramiro
    Alegre-Domingo, Teresa
    Faus-Matoses, Vicente
    Faus-Llacer, Vicente
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2013, 18 (03): : E533 - E536