Research on the standardization scheme of transmission line insulator fitting strings based on integrated universal design

被引:0
|
作者
Fang, Zhenggang [1 ]
Li, Yigang [1 ]
Liu, Rui [1 ]
Zhang, Jinfeng [2 ]
机构
[1] China Elect Power Res Inst, Beijing, Peoples R China
[2] State Grid Anhui Elect Power Co Ltd, Hefei, Peoples R China
关键词
transmission line; integrated universal design; fittings; insulator strings;
D O I
10.1109/ICEEPS62542.2024.10693077
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This article proposes the selection, design and parameters of insulator strings for integrated universal design transmission line fittings, provides reference values for the strength of insulator strings used in 35kV similar to 750kV transmission lines, and puts forward technical requirements for fitting design. By stipulating the matching and connection design of insulators and fittings, as well as the design of hanging points for fitting strings, a standardized scheme for fitting insulator strings of transmission lines at various voltage levels from 35kV similar to 750kV was proposed.
引用
收藏
页码:432 / 436
页数:5
相关论文
共 50 条
  • [21] Research of morphology of soft rime on suspension insulator for transmission line
    Yi-wei, Xue
    Yan-peng, Hao
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 319 - 322
  • [22] Computational analysis on voltage distribution along ceramic insulator strings of UHV AC transmission line
    Chen, Linhua
    Liang, Xidong
    Gaodianya Jishu/High Voltage Engineering, 2012, 38 (02): : 376 - 381
  • [23] Research and Design of Space-Sky-Ground Integrated Transmission Line Inspection Platform Based on Artificial Intelligence
    Huang, Lijun
    Xu, Dan
    Zhai, Denghui
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [24] Pollution characteristic of insulator strings for 1000 kV with transmission line double circuit on the same tower
    Xu, Tao
    Chen, Yong
    Meng, Gang
    Xie, Liang
    Xie, Xiong-Jie
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (09): : 2071 - 2075
  • [25] Icing flashover process and its influential factors of long insulator strings on the ehv transmission line
    Department of Electrical Engineering, North China Electric Power University, Baoding 071003, China
    不详
    不详
    Gaodianya Jishu, 2009, 3 (557-562):
  • [26] Integrated boundary protection scheme for power transmission line systems
    Bo, Z. Q.
    Zhang, B. H.
    He, J. H.
    Dong, X. Z.
    Caunce, B. R. J.
    Klimek, A.
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 470 - 475
  • [27] An Integrated Boundary Protection Scheme for Power Transmission Line Systems
    Bo, Zhiqian
    Zhang, Baohui
    He, Jinghan
    Dong, Xinzhou
    Klimek, Andrew
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2008, 9 (02):
  • [28] Icing Flashover Characteristics and Discharge Process of 500 kV AC Transmission Line Suspension Insulator Strings
    Liu, Yunpeng
    Gao, Song
    Huang, Daochun
    Yao, Tao
    Wu, Xiong
    Hu, Yi
    Cai, Wei
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (02) : 434 - 442
  • [29] Natural pollution accumulation characteristics of overhead transmission line insulator strings of Zhejiang electric power grid
    Wang, Shaohua
    Hu, Wentang
    Gong, Jiangang
    Pan, Jie
    Xu, Yangyong
    Liu, Haojun
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (04): : 1002 - 1009
  • [30] POWER ARC ON INSULATOR STRINGS - TESTING PROCEDURES AND DESIGN OF GUARD DEVICES FOR HV TRANSMISSION LINES
    BRASCA, E
    COMELLINI, E
    DELLOLIO, D
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (03): : 420 - +