Statistical analysis of natural and mechanical ventilation performance in improving indoor air quality, thermal comfort, and perceived air quality in a healthcare facility

被引:0
|
作者
Gholampour, Marzieh [1 ]
Taghipour, Malihe [1 ]
Tahavvor, Alireza [2 ]
Jafari, Saeed [3 ]
机构
[1] Islamic Azad Univ, Shiraz Branch, Fac Art & Architecture, Dept Architecture, Shiraz, Iran
[2] Islamic Azad Univ, Shiraz Branch, Dept Mech Engn, Shiraz, Iran
[3] Shiraz Univ Med Sci, Sch Hlth, Dept Occupat Hlth & Safety Engn, Shiraz, Iran
关键词
Indoor air quality; thermal comfort; perceived air quality; passive ventilation; volatile organic compounds; hospital; POLLUTION SOURCES; HOSPITALS; OLF;
D O I
10.1080/14733315.2024.2414663
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ventilation strategies in healthcare facilities are mainly directed towards mechanical systems. Due to patients' preferences or the necessity of terminal reheat/recool, Air Handler Units are often turned off or windows are opened when mechanical systems are active. This leads to poor IAQ, nosocomial infections, and energy loss. Besides, ventilation systems are not typically intended to optimize user satisfaction. Using field measurements in 140 spaces, survey studies, and statistical analysis, this study compares ventilation strategies in providing IAQ, thermal comfort, and Perceived Air Quality as an indicator of user satisfaction. 315 samples were collected for air velocity, air temperature, relative humidity, PAQ, odor intensity, and VOC concentrations. Lowest to highest pollutant concentrations were observed respectively in mechanical ventilation with two open windows, mechanical ventilation with one open window, natural ventilation with two open windows, mechanical ventilation with closed windows, natural ventilation with one open window, and nonventilated spaces. There was no evidence of an effect of ventilation strategies on environmental parameters and user satisfaction. Users' thermal comfort and air quality satisfaction were not guaranteed even when ventilation rate, pollutant concentrations, and environmental parameters were within the permissible range. Findings support the efficient performance of natural ventilation in providing acceptable air quality.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Analysis of thermal comfort and indoor air quality in a mechanically ventilated theatre
    Kavgic, M.
    Mumovic, D.
    Stevanovic, Z.
    Young, A.
    ENERGY AND BUILDINGS, 2008, 40 (07) : 1334 - 1343
  • [22] Thermal comfort and indoor air quality analysis of a lowenergy cooling windcatcher
    Calautit, John Kaiser
    Aquino, Angelo I.
    Shahzad, Sally
    Nasir, Diana S. N. M.
    Hughes, Ben Richard
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 2865 - 2870
  • [23] THE POTENTIAL OF NATURAL VENTILATION IN SINGLE-SIDED VENTILATED APARTMENT TO IMPROVE INDOOR THERMAL COMFORT AND AIR QUALITY
    Mohamed, M. F.
    Behnia, M.
    King, S.
    Prasad, D.
    PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, 2012, : 71 - 78
  • [24] Indoor air quality, thermal comfort and ventilation in deep energy retrofitted Irish dwellings
    Coggins, Ann Marie
    Wemken, Nina
    Mishra, Asit Kumar
    Sharkey, Martin
    Horgan, Liam
    Cowie, Hilary
    Bourdin, Emmanuel
    McIntyre, Brian
    BUILDING AND ENVIRONMENT, 2022, 219
  • [25] Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings
    Staveckis, Arturs
    Borodinecs, Anatolijs
    ENERGY AND BUILDINGS, 2021, 235
  • [26] Exploring the impact of perceived control on thermal comfort and indoor air quality perception in schools
    Torriani, Giulia
    Lamberti, Giulia
    Fantozzi, Fabio
    Babich, Francesco
    JOURNAL OF BUILDING ENGINEERING, 2023, 63
  • [27] Ventilation and Indoor Air Quality
    Kumar, Ashok
    Moreno-Rangel, Alejandro
    Khan, M. Amirul, I
    Piasecki, Michal
    ATMOSPHERE, 2022, 13 (10)
  • [28] Optimized performance of displacement ventilation aided with chair fans for comfort and indoor air quality
    Abou Hweij, Walid
    Ghaddar, Nesreen
    Ghali, Kamel
    Habchi, Carine
    ENERGY AND BUILDINGS, 2016, 127 : 907 - 919
  • [29] Numerical analysis on mechanical ventilation impact on indoor air quality in a basement
    Anyaegbuna, Benjamin E.
    Onokwai, Anthony O.
    Anyaegbuna, Ndubueze T.
    Iweriolor, Sunday
    Anyaegbuna, Ikechukwu D.
    Adegun, Isaac K.
    Fayomi, Ojo S.
    Ighravwe, Desmond E.
    Onifade, Morakinyo K.
    SCIENTIFIC AFRICAN, 2024, 25
  • [30] Comfort in closed spaces according to thermal comfort and indoor air quality
    Herczeg, Levente
    Hrustinszky, Tamás
    Kajtár, László
    Periodica Polytechnica Mechanical Engineering, 2000, 44 (02): : 249 - 264