Automatic operation method using wireless sensor networks for variable refrigerant flow system: Switchless control variable refrigerant flow system

被引:0
|
作者
Suzuki, Toshihiro [1 ]
Shimoda, Yoshiyuki [2 ]
Kobayashi, Akito [2 ]
Shiochi, Sumio [3 ]
机构
[1] Osaka Univ, Campus Sustainabil Off, Osaka, Japan
[2] Osaka Univ, Grad Sch Engn, Osaka, Japan
[3] Daikin Ind LTD, Technol & Innovat Ctr, Osaka, Japan
关键词
Variable refrigerant flow system; Energy efficiency; Medium-sized buildings; Sensor networks; AIR-CONDITIONING SYSTEM; ENERGY PERFORMANCE; VRF; SAVINGS;
D O I
10.1016/j.enbuild.2025.115379
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Variable refrigerant flow (VRF) systems autonomously operate using built-in sensors regulated by remote settings and indoor unit intake temperatures. However, in larger spaces with multiple indoor and outdoor units, autonomous VRF systems lack the benefits of an integrated system, such as balanced load distribution, coordinated operation, and efficient ventilation. To overcome these challenges, the authors developed a "switchless VRF system" designed for small to medium-sized buildings. This system improves comfort and energy efficiency by eliminating extensive control mechanisms and switches, ensuring uniform performance and greater energy saving. We performed detailed demonstration experiments to evaluate the system's effectiveness across four key functions (pre-cooling and pre-heating, human sensing HVAC control, outdoor unit rotation control, and indoor unit fan power reduction functions). In the first control, the VRF system demonstrated significant energy efficiency, achieving 18 % energy saving in summer pre-cooling. In the second, the human-detection ventilation control effectively modulated the ventilation volume by real-time monitoring of the number of occupants, resulting in approximately 35 % energy saving. In the third, the rotational control strategy enhanced the average COP of the outdoor units by 17.7 %. In the fourth, a reduction in indoor-unit fan power led to an overall power consumption decrease of 8.6 % by ceasing fan operation when the thermostat was deactivated. This innovation addresses the modern needs of building management and energy conservation, making it a viable option for enhancing HVAC operations.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Variable refrigerant flow systems: A review
    Aynur, Tolga N.
    ENERGY AND BUILDINGS, 2010, 42 (07) : 1106 - 1112
  • [32] A machine learning bayesian network for refrigerant charge faults of variable refrigerant flow air conditioning system
    Hu, Min
    Chen, Huanxin
    Shen, Limei
    Li, Guannan
    Guo, Yabin
    Li, Haorong
    Li, Jiong
    Hu, Wenju
    ENERGY AND BUILDINGS, 2018, 158 : 668 - 676
  • [33] Machine learning based diagnosis strategy for refrigerant charge amount malfunction of variable refrigerant flow system
    Li, Zhengfei
    Shi, Shubiao
    Chen, Huanxin
    Wei, Wentian
    Wang, Yuzhou
    Liu, Qian
    Liu, Tao
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 110 (110) : 95 - 105
  • [34] Optimal control of combined air conditioning system with variable refrigerant flow and variable air volume for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Fang, Xing
    Du, Zhimin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 42 : 14 - 25
  • [35] Improved solar milk chilling system using variable refrigerant flow technology (VRF)
    Khan, Khawar Saeed
    Amjad, Waseem
    Munir, Anjum
    Hensel, Oliver
    SOLAR ENERGY, 2020, 197 (197) : 317 - 325
  • [36] Extending the virtual refrigerant charge sensor (VRC) for variable refrigerant flow (VRF) air conditioning system using data-based analysis methods
    Li, Guannan
    Hu, Yunpeng
    Chen, Huanxin
    Shen, Limei
    Li, Haorong
    Li, Jiong
    Hu, Wenju
    APPLIED THERMAL ENGINEERING, 2016, 93 : 908 - 919
  • [37] Artificial Neural Network-Based Control of a Variable Refrigerant Flow System in the Cooling Season
    Kang, Insung
    Lee, Kwang Ho
    Lee, Je Hyeon
    Moon, Jin Woo
    ENERGIES, 2018, 11 (07):
  • [38] A hybrid ICA-BPNN-based FDD strategy for refrigerant charge faults in variable refrigerant flow system
    Sun, Shaobo
    Li, Guannan
    Chen, Huanxin
    Huang, Qianyun
    Shi, Shubiao
    Hu, Wenju
    APPLIED THERMAL ENGINEERING, 2017, 127 : 718 - 728
  • [39] Improvement of variable refrigerant flow system performance using energy saving control strategy and chilled water storage
    Lin, Xiaojie
    Ling, Jiazhen
    Hwang, Yunho
    Radermacher, Reinhard
    Kim, Byungsoon
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (05) : 483 - 491
  • [40] Online optimal control of variable refrigerant flow and variable air volume combined air conditioning system for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fang, Xing
    APPLIED THERMAL ENGINEERING, 2015, 80 : 87 - 96