Commissioning of a motion management system for a 1.5T Elekta Unity MR-Linac: A single institution experience

被引:0
|
作者
Smith, Blake R. [1 ]
St-Aubin, Joel [1 ]
Hyer, Daniel E. [1 ]
机构
[1] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
关键词
commissioning; gating; motion management; MR-Linac; unity; ADAPTIVE RADIOTHERAPY; RESPIRATORY MOTION; RADIATION-THERAPY; QUALITY-ASSURANCE; IMPLEMENTATION; TRACKING; LUNG;
D O I
10.1002/acm2.70005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis work describes a single institution experience of commissioning a real-time target tracking and beam control system, known as comprehensive motion management, for a 1.5 T Elekta MR-Linac.MethodsAnatomical tracking and radiation beam control were tested using the MRI4D Quasar motion phantom. Multiple respiratory breathing traces were modeled across a range of realistic regular and irregular breathing patterns ranging between 10 and 18 breaths per minute. Each of the breathing traces was used to characterize the anatomical position monitoring (APM) accuracy, and beam latency, and to quantify the dosimetric impact of both parameters during a respiratory-gated delivery using EBT3 film dosimetry. Additional commissioning tasks were performed to verify the dosimetric constancy during beam gating and to expand our existing quality assurance program.ResultsIt was determined that APM correctly predicted the 3D position of a dynamically moving tracking target to within 1.5 mm for 95% of the imaging frames with no deviation exceeding 2 mm. Among the breathing traces investigated, the mean latency ranged between -21.7 and 7.9 ms with 95% of all observed latencies within 188.3 ms. No discernable differences were observed in the relative profiles or cumulative output for a gated beam relative to an ungated beam with minimal dosimetric impact observed due to system latency. Measured dose profiles for all gated scenarios retained a gamma pass rate of 97% or higher for a 3%/2 mm criteria relative to a theoretical gated dose profile without latency or tracking inaccuracies.ConclusionMRI-guided target tracking and automated beam delivery control were successfully commissioned for the Elekta Unity MR-Linac. These gating features were shown to be highly accurate with an effectively small beam latency for a range of regular and irregular respiratory breathing traces.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Performance characterization of the Blue Physics scintillator in the 1.5T MR-linac
    Oolbekkink, S.
    van Asselen, B.
    Woodings, S.
    Wolthaus, J.
    de Vries, W.
    van Appeldoorn, A.
    Feijoo, M.
    van den Dobbelsteen, M.
    Raaymakers, B.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S470 - S471
  • [32] Treating patients with a cardiac implant on a 1.5T MR-linac: a multi-centre experience
    Keesman, R.
    van der Bijl, E.
    Kerkmeijer, L.
    Tyagi, N.
    Akdag, O.
    Wolthaus, J.
    van de Pol, S.
    Noteboom, J.
    Intven, M.
    Fast, M.
    van Lier, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S746 - S747
  • [33] Inter- and intrafraction organ motion for cervical cancer patients treated on a 1.5T MR-Linac
    Ding, S.
    Liu, H.
    Wang, B.
    Li, Y.
    Liu, B.
    Ouyang, Y.
    Huang, X.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1263 - S1263
  • [34] The Dosimetric Feasibility of the 1.5T MR-Linac System for Esophageal Cancer: The Impact of the Magnetic Field
    Li, Z.
    Yin, Y.
    Zhu, J.
    Li, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S187 - S187
  • [35] Time-course assessment of 3D-image distortion on the 1.5 T Marlin/Elekta Unity MR-LINAC
    Damyanovich, Andrei Z.
    Tadic, Tony
    Foltz, Warren D.
    Jelveh, Salomeh
    Bissonnette, Jean-Pierre
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 100 : 90 - 98
  • [36] Time-course assessment of 3D-image distortion on the 1.5 T Marlin/Elekta Unity MR-LINAC
    Damyanovich, Andrei Z.
    Tadic, Tony
    Foltz, Warren D.
    Jelveh, Salomeh
    Bissonnette, Jean-Pierre
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 100 : 90 - 98
  • [37] An efficient setup for weekly dose output constancy of a 1.5T MR-Linac
    Yang, B.
    Lam, W. W.
    Ho, Y. W.
    Ho, C. C.
    Hung, C.
    Cheung, K. Y.
    Yu, S. K.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S710 - S711
  • [38] Optimizing MRI Readout of Fricke Gel Dosimeters On a 1.5T MR-Linac
    MacCallum, M.
    Malajovich, I.
    Serai, S.
    Salzillo, T.
    Dresner, A.
    Ibbott, G.
    Kim, L.
    MEDICAL PHYSICS, 2022, 49 (06) : E768 - E769
  • [39] Prostate intrafraction motion during the preparation and delivery of MR-guided radiotherapy sessions on a 1.5T MR-Linac
    Keizer, D. M. de Muinck
    Kerkmeijer, G. W.
    Willigenburg, T.
    van Lier, A. L. H. M. W.
    den Hartogh, M. D.
    van Zyp, J. R. N. van der Voort
    de Groot-van Breugel, E. N.
    Raaymakers, B. W.
    Lagendijk, J. J. W.
    de Boer, J. C. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 151 : 88 - 94
  • [40] Preliminary functional imaging study on an integrated 1.5T MR-Linac machine
    Kadbi, M.
    Ding, Y.
    Wang, J.
    Fuller, C. D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S915 - S916