Commissioning of a motion management system for a 1.5T Elekta Unity MR-Linac: A single institution experience

被引:0
|
作者
Smith, Blake R. [1 ]
St-Aubin, Joel [1 ]
Hyer, Daniel E. [1 ]
机构
[1] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
关键词
commissioning; gating; motion management; MR-Linac; unity; ADAPTIVE RADIOTHERAPY; RESPIRATORY MOTION; RADIATION-THERAPY; QUALITY-ASSURANCE; IMPLEMENTATION; TRACKING; LUNG;
D O I
10.1002/acm2.70005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis work describes a single institution experience of commissioning a real-time target tracking and beam control system, known as comprehensive motion management, for a 1.5 T Elekta MR-Linac.MethodsAnatomical tracking and radiation beam control were tested using the MRI4D Quasar motion phantom. Multiple respiratory breathing traces were modeled across a range of realistic regular and irregular breathing patterns ranging between 10 and 18 breaths per minute. Each of the breathing traces was used to characterize the anatomical position monitoring (APM) accuracy, and beam latency, and to quantify the dosimetric impact of both parameters during a respiratory-gated delivery using EBT3 film dosimetry. Additional commissioning tasks were performed to verify the dosimetric constancy during beam gating and to expand our existing quality assurance program.ResultsIt was determined that APM correctly predicted the 3D position of a dynamically moving tracking target to within 1.5 mm for 95% of the imaging frames with no deviation exceeding 2 mm. Among the breathing traces investigated, the mean latency ranged between -21.7 and 7.9 ms with 95% of all observed latencies within 188.3 ms. No discernable differences were observed in the relative profiles or cumulative output for a gated beam relative to an ungated beam with minimal dosimetric impact observed due to system latency. Measured dose profiles for all gated scenarios retained a gamma pass rate of 97% or higher for a 3%/2 mm criteria relative to a theoretical gated dose profile without latency or tracking inaccuracies.ConclusionMRI-guided target tracking and automated beam delivery control were successfully commissioned for the Elekta Unity MR-Linac. These gating features were shown to be highly accurate with an effectively small beam latency for a range of regular and irregular respiratory breathing traces.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Commissioning an Independent Dose Calculation System for the Unity MR-Linac
    Goodwin, E.
    Nill, S.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S978 - S979
  • [22] Patient expectation and experience of MR-guided radiotherapy using a 1.5T MR-Linac
    van Otterloo, S. R. de Mol
    Westerhoff, J. M.
    Leer, T.
    Rutgers, R. H. A.
    Meijers, L. T. C.
    Daamen, L. A.
    Intven, M. P. W.
    Verkooijen, H. M.
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2024, 29
  • [23] Intravoxel Incoherent Motion Analysis of Cervical Cancer tumours on 1.5T MR-Linac
    Ingle, Manasi
    Blackledge, Matthew
    Wetscherek, Andreas
    Alexander, Sophie
    Nartey, Jayde
    McNair, Helen
    Hafeez, Shaista
    Bhide, Shreerang
    Lalondrelle, Susan
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4988 - S4990
  • [24] Online Adaptive Planning Strategy for 1.5T MR-Linac
    Yang, J.
    Sobremonte, A.
    Vedam, S.
    Brock, K.
    Ohrt, A.
    Fuller, C.
    Choi, S.
    Jhingran, A.
    Castillo, P.
    Lee, B.
    Wang, J.
    Hughes, N.
    Mohammadsaid, M.
    Balter, P.
    MEDICAL PHYSICS, 2020, 47 (06) : E643 - E643
  • [25] Gated Beam Dosimetry Properties of a 1.5T MR-Linac
    Chen, X.
    Omari, E.
    Tai, A.
    Jassar, H.
    Zhang, Y.
    Paulson, E.
    Ahunbay, E.
    Sandin, C.
    Kydonieos, M.
    Li, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E318 - E318
  • [26] Pulse sequence optimization in pelvis on a 1.5T MR-Linac
    Zhou, Y.
    Yuan, J.
    Ho, Y. W.
    Yang, B.
    Ho, L. C.
    Cheung, K. Y.
    Yu, S. K.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S963 - S963
  • [27] Proof-of-concept delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac
    Kontaxis, C.
    Woodhead, P. L.
    Bol, G. H.
    Lagendijk, J. J. W.
    Raaymakers, B. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (04):
  • [28] Implementation of the 1.5T MR-linac: healthy volunteers, screen recording and initial experience
    Michel, M.
    Paquier, Z.
    Alghamdi, H.
    Bouchart, C.
    Collen, C.
    Gulyban, A.
    Martinive, P.
    Reynaert, N.
    Van Gestel, D.
    Van den Begin, R.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S860 - S861
  • [29] Repeatability of abdominal DWI using different motion compensation techniques on a 1.5T MR-Linac
    Baas, Koen P. A.
    Visser, Sabine
    van Pelt, Vivian W. J.
    McHugh, Damien J.
    Thorwarth, Daniela
    Wetscherek, Andreas
    Schakel, Tim
    Kruiskamp, Marijn
    Wang, Jihong
    Nowee, Marlies E.
    van der Heide, Uulke A.
    Paulson, Eric S.
    van Houdt, Petra J.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3859 - S3862
  • [30] Time trends for online adapative treatment on the 1.5T MR-Linac
    Westerhoff, J.
    Daamen, A.
    de Groot-van Breugel, E. N.
    van Zyp, J. R. N. van der Voort
    Verhoeff, J. J. C.
    Mook, S.
    Verkooijen, H. M.
    Intven, M. P. W.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S110 - S111