Commissioning of a motion management system for a 1.5T Elekta Unity MR-Linac: A single institution experience

被引:0
|
作者
Smith, Blake R. [1 ]
St-Aubin, Joel [1 ]
Hyer, Daniel E. [1 ]
机构
[1] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
关键词
commissioning; gating; motion management; MR-Linac; unity; ADAPTIVE RADIOTHERAPY; RESPIRATORY MOTION; RADIATION-THERAPY; QUALITY-ASSURANCE; IMPLEMENTATION; TRACKING; LUNG;
D O I
10.1002/acm2.70005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis work describes a single institution experience of commissioning a real-time target tracking and beam control system, known as comprehensive motion management, for a 1.5 T Elekta MR-Linac.MethodsAnatomical tracking and radiation beam control were tested using the MRI4D Quasar motion phantom. Multiple respiratory breathing traces were modeled across a range of realistic regular and irregular breathing patterns ranging between 10 and 18 breaths per minute. Each of the breathing traces was used to characterize the anatomical position monitoring (APM) accuracy, and beam latency, and to quantify the dosimetric impact of both parameters during a respiratory-gated delivery using EBT3 film dosimetry. Additional commissioning tasks were performed to verify the dosimetric constancy during beam gating and to expand our existing quality assurance program.ResultsIt was determined that APM correctly predicted the 3D position of a dynamically moving tracking target to within 1.5 mm for 95% of the imaging frames with no deviation exceeding 2 mm. Among the breathing traces investigated, the mean latency ranged between -21.7 and 7.9 ms with 95% of all observed latencies within 188.3 ms. No discernable differences were observed in the relative profiles or cumulative output for a gated beam relative to an ungated beam with minimal dosimetric impact observed due to system latency. Measured dose profiles for all gated scenarios retained a gamma pass rate of 97% or higher for a 3%/2 mm criteria relative to a theoretical gated dose profile without latency or tracking inaccuracies.ConclusionMRI-guided target tracking and automated beam delivery control were successfully commissioned for the Elekta Unity MR-Linac. These gating features were shown to be highly accurate with an effectively small beam latency for a range of regular and irregular respiratory breathing traces.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Commissioning of a 1.5T Elekta Unity MR-linac: A single institution experience
    Snyder, Jeffrey E.
    St-Aubin, Joel
    Yaddanapudi, Sridhar
    Boczkowski, Amanda
    Dunkerley, David A. P.
    Graves, Stephen A.
    Hyer, Daniel E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 160 - 172
  • [2] Commissioning measurements on an Elekta Unity MR-Linac
    Powers, Marcus
    Baines, John
    Crane, Robert
    Fisher, Chantelle
    Gibson, Stephen
    Marsh, Linda
    Oar, Bronwyn
    Shoobridge, Ariadne
    Simpson-Page, Emily
    Van der Walt, Marchant
    de Vine, Glenn
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (02) : 457 - 473
  • [3] Commissioning measurements on an Elekta Unity MR-Linac
    Marcus Powers
    John Baines
    Robert Crane
    Chantelle Fisher
    Stephen Gibson
    Linda Marsh
    Bronwyn Oar
    Ariadne Shoobridge
    Emily Simpson-Page
    Marchant Van der Walt
    Glenn de Vine
    Physical and Engineering Sciences in Medicine, 2022, 45 : 457 - 473
  • [4] Assessing Artefacts of Cardiac Pacemakers and Leads at a 1.5T Elekta Unity MR-Linac
    Lee, D.
    Trombetta, M.
    Shaw, G.
    Oh, S.
    Hwang, M.
    Pavord, D.
    Sohn, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E183 - E183
  • [5] Single Institution Experience of Adjuvant Partial Breast Radiotherapy on the Elekta 1.5T MR Linac
    Tan, I. Z.
    Mitchell, A.
    Chick, J.
    Sullivan, J.
    Morgan, T.
    Lawes, R.
    Herbert, T.
    McNair, H.
    Kirby, A. M.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S658 - S659
  • [6] Elekta Unity MR-linac commissioning: mechanical and dosimetry tests
    Tsuneda, Masato
    Abe, Kota
    Fujita, Yukio
    Ikeda, Yohei
    Furuyama, Yoshinobu
    Uno, Takashi
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (01) : 73 - 84
  • [7] Time management and hands-on experience with ELEKTA Unity 1.5T MRI-Linac
    Marks, C.
    Stolte, A.
    Thorwarth, D.
    Braun, L. H.
    Boeke, S.
    Wegener, D.
    Boldt, J.
    Ortinau, C.
    Kammler, M.
    Holl-Henkel, B.
    Gani, C.
    Zips, D.
    Nachbar, M.
    Dohm, O.
    Moennich, D.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S608 - S608
  • [8] Performance of a multileaf collimator system for a 1.5T MR-linac
    Zhang, Ke
    Tian, Yuan
    Li, Minghui
    Men, Kuo
    Dai, Jianrong
    MEDICAL PHYSICS, 2021, 48 (02) : 546 - 555
  • [9] MRI commissioning of 1.5T MR-linac systems - a multi-institutional study
    Tijssen, Rob H. N.
    Philippens, Marielle E. P.
    Paulson, Eric S.
    Glitzner, Markus
    Chugh, Brige
    Wetscherek, Andreas
    Dubec, Michael
    Wang, Jihong
    van der Heide, Uulke A.
    RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 114 - 120
  • [10] Comprehensive MRI Acceptance Testing & Commissioning of a 1.5T MR-Linac: Guidelines and Results
    Tijssen, R. H. N.
    Crijns, S. P. M.
    Bluemink, J. J.
    Hacket, S. S.
    DeVries, J. H. W.
    Kruiskamp, M. J.
    Philippens, M. E. P.
    Lagendijk, J. J. W.
    Raaymakers, B. W.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S130 - S131