An Analytical Model for the Steady-State Thermal Analysis of Façade-Integrated PV Modules Cooled by a Solar Chimney

被引:0
|
作者
Sucurovic, Marko [1 ]
Klimenta, Dardan [2 ]
Andriukaitis, Darius [3 ]
Zilys, Mindaugas [3 ]
Sledevic, Tomyslav [4 ]
Tomovic, Milan [5 ]
机构
[1] Univ Kragujevac, Fac Tech Sci Cacak, Dept Power Engn, Svetog Save St 65, Cacak RS-32102, Serbia
[2] Univ Pristina Kosovska Mitrov, Fac Tech Sci, Dept Power Engn, Kneza Milosa St 7, RS-38220 Kosovska Mitrovica, Serbia
[3] Kaunas Univ Technol, Fac Elect & Elect Engn, Dept Elect Engn, Studentu G 50-438, LT-51368 Kaunas, Lithuania
[4] Vilnius Gediminas Tech Univ, Dept Elect Syst, Sauletekio Ave 11, LT-10223 Vilnius, Lithuania
[5] Kosovo & Metohija Acad Appl Studies, Dept Zvecan, Nusiceva St 6, RS-38227 Zvecan, Serbia
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 03期
关键词
air velocity; analytical model; photovoltaic (PV) module; solar chimney; steady-state thermal analysis; temperature; HEAT-TRANSFER; POWER-PLANT; ENHANCEMENT; SYSTEM;
D O I
10.3390/app15031664
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper proposes a steady-state thermal model for the passive cooling of photovoltaic (PV) modules integrated into a vertical building fa & ccedil;ade by means of a solar chimney, including an empirical correlation for turbulent free convection from a vertical isothermal plate. The proposed analytical model estimates the air velocities at the inlet and at the outlet of the ventilation channel of such a cooling system and the average temperature of the fa & ccedil;ade-integrated PV modules. A configuration composed of a maximum of six vertically installed PV modules and one solar chimney is considered. The air velocities at the inlet and at the outlet of the ventilation channel obtained for the case of installing PV modules on the building fa & ccedil;ade are compared with those calculated for the case where the PV modules are integrated into the roof with a slope of 37 degrees. By comparing each of the solutions with one PV module to the corresponding one with six PV modules, it was found that the increase in the air velocity due to the effects of the solar irradiance and the height difference between the two openings of the ventilation channel ranges between 41.05% in the case of "Roof" and 141.14% in the case of "Fa & ccedil;ade". In addition, it was obtained that an increase in the solar chimney height of 1 m leads to a decrease in the average PV section temperature by 1.95-7.21% and 0.65-2.92% in the cases of "Roof" and "Fa & ccedil;ade", respectively. Finally, the obtained results confirmed that the use of solar chimneys for passive cooling of fa & ccedil;ade-integrated PV modules is technically justified.
引用
收藏
页数:20
相关论文
共 33 条
  • [31] A reliable FEA-based calculation approach of convective heat transfer coefficient for Steady-State Thermal analysis of X-ray water-cooled mirrors
    Li, Tong
    Jin, Limin
    Zhu, Wanqian
    Chen, Jiahua
    Xue, Song
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1040
  • [32] A reliable FEA-based calculation approach of convective heat transfer coefficient for Steady-State Thermal analysis of X-ray water-cooled mirrors
    Li, Tong
    Jin, Limin
    Zhu, Wanqian
    Chen, Jiahua
    Xue, Song
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1040
  • [33] Full year performance analysis and steady state operation model for a stationary Shadeless solar thermal collector with a horizontal aperture for steam generation
    Abido, Mahmoud
    Widyolar, Bennett
    Bhusal, Yogesh
    Brinkley, Jordyn
    Winston, Roland
    Kurtz, Sarah
    SOLAR ENERGY, 2024, 276