An Analytical Model for the Steady-State Thermal Analysis of Façade-Integrated PV Modules Cooled by a Solar Chimney

被引:0
|
作者
Sucurovic, Marko [1 ]
Klimenta, Dardan [2 ]
Andriukaitis, Darius [3 ]
Zilys, Mindaugas [3 ]
Sledevic, Tomyslav [4 ]
Tomovic, Milan [5 ]
机构
[1] Univ Kragujevac, Fac Tech Sci Cacak, Dept Power Engn, Svetog Save St 65, Cacak RS-32102, Serbia
[2] Univ Pristina Kosovska Mitrov, Fac Tech Sci, Dept Power Engn, Kneza Milosa St 7, RS-38220 Kosovska Mitrovica, Serbia
[3] Kaunas Univ Technol, Fac Elect & Elect Engn, Dept Elect Engn, Studentu G 50-438, LT-51368 Kaunas, Lithuania
[4] Vilnius Gediminas Tech Univ, Dept Elect Syst, Sauletekio Ave 11, LT-10223 Vilnius, Lithuania
[5] Kosovo & Metohija Acad Appl Studies, Dept Zvecan, Nusiceva St 6, RS-38227 Zvecan, Serbia
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 03期
关键词
air velocity; analytical model; photovoltaic (PV) module; solar chimney; steady-state thermal analysis; temperature; HEAT-TRANSFER; POWER-PLANT; ENHANCEMENT; SYSTEM;
D O I
10.3390/app15031664
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper proposes a steady-state thermal model for the passive cooling of photovoltaic (PV) modules integrated into a vertical building fa & ccedil;ade by means of a solar chimney, including an empirical correlation for turbulent free convection from a vertical isothermal plate. The proposed analytical model estimates the air velocities at the inlet and at the outlet of the ventilation channel of such a cooling system and the average temperature of the fa & ccedil;ade-integrated PV modules. A configuration composed of a maximum of six vertically installed PV modules and one solar chimney is considered. The air velocities at the inlet and at the outlet of the ventilation channel obtained for the case of installing PV modules on the building fa & ccedil;ade are compared with those calculated for the case where the PV modules are integrated into the roof with a slope of 37 degrees. By comparing each of the solutions with one PV module to the corresponding one with six PV modules, it was found that the increase in the air velocity due to the effects of the solar irradiance and the height difference between the two openings of the ventilation channel ranges between 41.05% in the case of "Roof" and 141.14% in the case of "Fa & ccedil;ade". In addition, it was obtained that an increase in the solar chimney height of 1 m leads to a decrease in the average PV section temperature by 1.95-7.21% and 0.65-2.92% in the cases of "Roof" and "Fa & ccedil;ade", respectively. Finally, the obtained results confirmed that the use of solar chimneys for passive cooling of fa & ccedil;ade-integrated PV modules is technically justified.
引用
收藏
页数:20
相关论文
共 33 条
  • [21] Two-dimensional steady-state thermal analytical model of permanent-magnet synchronous machines operating in generator mode
    Khedda, Zakarya Djelloul
    Boughrara, Kamel
    Dubas, Frederic
    Guo, Baocheng
    Ailam, El Hadj
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2022, 41 (01) : 125 - 154
  • [22] Steady-State Thermal Analysis of an Integrated 160 GHz Balanced Quadrupler Based on Quasi-Vertical Schottky Diodes
    Nadri, Souheil
    Xie, Linli
    Alijabbari, Naser
    Gaskins, John T.
    Foley, Brian M.
    Hopkins, Patrick E.
    Weikle, Robert M., II
    2015 40TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES (IRMMW-THZ), 2015,
  • [23] Steady-State Analysis of the Thermal Subsystem Within Green Integrated-Energy Systems: A Novel Mathematical Modelling Approach
    Zhou, Jia
    Liang, Dongling
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2023, 41 (03) : 639 - 648
  • [25] Integrated Steady-State System Package for Nuclear Thermal Propulsion Analysis Using Multi-Dimensional Thermal Hydraulics and Dimensionless Turbopump Treatment
    Myers, Rory
    Dehart, Mark
    Kotlyar, Dan
    ENERGIES, 2024, 17 (13)
  • [26] THERMAL-HYDRAULIC ANALYSIS OF A HIGH-TEMPERATURE HELIUM-GAS-COOLED REACTOR UNDER VARIOUS STEADY-STATE OPERATING CONDITIONS
    Hutli, Ezddin
    Kridan, Ramadan
    HEAT TRANSFER RESEARCH, 2023, 54 (15) : 71 - 94
  • [27] Effect of steady-state and unstable-state inlet boundary on the thermal performance of packed-bed latent heat storage system integrated with concentrating solar collectors
    Wang, Wei
    Shuai, Yong
    Qiu, Jun
    He, Xibo
    Hou, Yicheng
    RENEWABLE ENERGY, 2022, 183 : 251 - 266
  • [28] State Space Model for Thermal Analysis of Integrated Structure of Flat Plate Solar Collector and Building Envelope
    Yu, Guoqing
    Zhou, Jirui
    Tang, Yongqiang
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (06):
  • [29] Analytical Model for Thermal Assessment of a Vertical Double U-Tube Ground-Coupled Heat Pump System Operates at Steady-State Conditions
    Tarrad, Ali H.
    FDMP-FLUID DYNAMICS & MATERIALS PROCESSING, 2022, 18 (04): : 1111 - 1127
  • [30] Thermal performance analysis on steady-state and dynamic response characteristic in solar tower power plant based on supercritical carbon dioxide Brayton cycle
    Chen, Kai-Qi
    Pu, Wen-Hao
    Zhang, Qi
    Lan, Bing-Song
    Song, Zhang-Yang
    Mao, Yan-Qin
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 1927 - 1949