Influence of template design on the accuracy of static computer-assisted implant surgery

被引:0
|
作者
Chung, Jinmook [1 ]
Park, Junghyun [1 ]
Son, Hyeonseong [1 ]
Hong, Seoung-Jin [2 ]
Pae, Ahran [2 ]
机构
[1] Kyung Hee Univ, Grad Sch, Dept Dent, Seoul, South Korea
[2] Kyung Hee Univ, Coll Dent, Dept Prosthodont, 26 Kyungheedae Ro, Seoul 02447, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2025年 / 17卷 / 01期
关键词
Guided surgery; Implant; Open sleeve; Static computer-assisted implant surgery (s-CAIS); Surgical template; STEREOLITHOGRAPHIC SURGICAL GUIDES; PLACEMENT; TOMOGRAPHY; TOLERANCE; PRECISION; IMAGES;
D O I
10.4047/jap.2025.17.1.22
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study aimed to evaluate the accuracy of static computer- assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs. MATERIALS AND METHODS. Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1-4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5-6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models. RESULTS. While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation. CONCLUSION. Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
引用
收藏
页码:22 / 35
页数:14
相关论文
共 50 条
  • [41] The Influence of Surgical Experience and Bone Density on the Accuracy of Static Computer-Assisted Implant Surgery in Edentulous Jaws Using a Mucosa-Supported Surgical Template with a Half-Guided Implant Placement Protocol-A Randomized Clinical Study
    Kivovics, Marton
    Penzes, Dorottya
    Nemeth, Orsolya
    Mijiritsky, Eitan
    MATERIALS, 2020, 13 (24) : 1 - 12
  • [42] Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies
    Jain, Saurabh
    Sayed, Mohammed E.
    Ibraheem, Wael I.
    Ageeli, Abrar A.
    Gandhi, Sumir
    Jokhadar, Hossam F.
    Alresayes, Saad Saleh
    Alqarni, Hatem
    Alshehri, Abdullah Hasan
    Huthan, Halah Mohammed
    Alami, Atheer
    Al Wadei, Mohammed Hussain Dafer
    Aljabri, Yahya
    MEDICINA-LITHUANIA, 2024, 60 (01):
  • [43] COMPUTER-ASSISTED TEMPLATE LAYOUT
    SMITH, JE
    IEEE COMPUTER GROUP NEWS, 1970, 3 (03): : 65 - &
  • [44] Comparison of the accuracy of implant position among freehand implant placement, static and dynamic computer-assisted implant surgery in fully edentulous patients: a non- randomized prospective study
    Jaemsuwan, S.
    Arunjaroensuk, S.
    Kaboosaya, B.
    Subbalekha, K.
    Mattheos, N.
    Pimkhaokham, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 52 (02) : 264 - 271
  • [45] Accuracy of implant placement via dynamic navigation and autonomous robotic computer-assisted implant surgery methods: A retrospective study
    Zhang, Sihui
    Cai, Qin
    Chen, Weiyi
    Lin, Yuxuan
    Gao, Yan
    Wu, Dong
    Chen, Jiang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (02) : 220 - 229
  • [46] Computer-assisted bone reduction and static computer-guided implant surgery in a fully edentulous patient: a technique report
    Lanis, Alejandro
    Tahmaseb, Ali
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2021, 24 (02) : 165 - 179
  • [47] Accuracy of robotic computer-assisted implant surgery in clinical studies: a systematic review and meta-analysis
    Zixin Luo
    An Li
    Alexey Unkovskiy
    Jiang Li
    Florian Beuer
    Zhe Wu
    Ping Li
    BMC Oral Health, 25 (1)
  • [48] Accuracy assessment of computer-assisted flapless implant placement in partial edentulism
    Van Assche, N.
    van Steenberghe, D.
    Quirynen, M.
    Jacobs, R.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2010, 37 (04) : 398 - 403
  • [49] Comparison of Implant Placement Accuracy in Healed and Fresh Extraction Sockets between Static and Dynamic Computer-Assisted Implant Surgery Navigation Systems: A Model-Based Evaluation
    Wang, Miaozhen
    Rausch-Fan, Xiaohui
    Zhan, Yalin
    Shen, Huidan
    Liu, Feng
    MATERIALS, 2022, 15 (08)
  • [50] Computer-assisted implant placement: Scan template, SimPlant, SurgiGuide, and SAFE system
    Tardieu, Philippe B.
    Vrielinck, Luc
    Escolano, Eric
    Henne, Michel
    Tardieu, Anne-Laure
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2007, 27 (02) : 141 - 149