The MyFlex-ζ Foot: A Variable Stiffness ESR Ankle-Foot Prosthesis

被引:0
|
作者
Tabucol, Johnnidel [1 ]
Kooiman, Vera G. M. [2 ,3 ]
Leopaldi, Marco [1 ]
Leijendekkers, Ruud [4 ,5 ]
Selleri, Giacomo [1 ]
Mellini, Marcello [1 ]
Verdonschot, Nico [6 ,7 ]
Oddsson, Magnus [8 ]
Carloni, Raffaella [9 ]
Zucchelli, Andrea [1 ]
Brugo, Tommaso M. [1 ]
机构
[1] Univ Bologna, Dept Ind Engn, I-40131 Bologna, Italy
[2] Radboud Univ Nijmegen, Med Ctr, Orthoped Res Lab, Dept Rehabil, NL-6500 HB Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Donders Inst Brain Cognit & Behav, NL-6500 HB Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Donders Inst Brain Cognit & Behav, Radboud Inst Hlth Sci, Orthoped Res Lab,Dept Rehabil,Med Ctr, NL-6500 HB Nijmegen, Netherlands
[5] Radboud Univ Nijmegen, Med Ctr, IQ Healthcare, NL-6500 HB Nijmegen, Netherlands
[6] Radboud Univ Nijmegen, Med Ctr, Orthoped Res Lab, NL-6500 HB Nijmegen, Netherlands
[7] Univ Twente, Fac Engn & Technol, Dept Biomech Engn, NL-7500 AE Enschede, Netherlands
[8] Ossur, IS-110 Reykjavik, Iceland
[9] Univ Groningen, Fac Sci & Engn, Dept Artificial Intelligence, Bernoulli Inst Math Comp Sci & Artificial Intelli, Groningen, Netherlands
关键词
Foot; Prosthetics; Legged locomotion; Ankle; Particle measurements; Force; Atmospheric measurements; Costs; Blades; Biomechanics; Amputation; biomechanical tests; prosthesis design; prosthetic feet; variable stiffness; TRANSTIBIAL AMPUTEES; POWERED KNEE; WALKING; AMPUTATION; DESIGN; ACTUATOR; FEET;
D O I
10.1109/TNSRE.2025.3534096
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most commercially available foot prostheses are passive ESR feet, which store and release energy to reduce metabolic costs and improve comfort but cannot adjust to varying walking conditions. In contrast, bionic feet adapt to different tasks but are hindered by high weight, power consumption, and cost. This paper presents MyFlex- zeta , an ESR foot with a variable stiffness system, as a compromise between these two categories. MyFlex- zeta adjusts stiffness by varying the sagittal-plane distance between two key points, altering force interactions within the prosthesis and affecting overall stiffness. Clinical tests with three transfemoral amputees evaluated stiffness variation across two sessions: the first subjective, where participants assessed stiffness settings during different tasks, and the second biomechanical, measuring performance parameters. Two participants selected different stiffness settings for various tasks, while the third, with limited perception of stiffness changes, showed less distinction in outcomes. Greater sagittal-plane rotation and higher energy absorption were observed in most tasks with more compliant settings, although one participant's results were limited due to selecting close stiffness settings. Overall, these findings suggest MyFlex- zeta offers adaptability and performance improvements over traditional ESR feet. With further actuation and control system development, MyFlex- zeta could mark significant progress in prosthesis technology.
引用
收藏
页码:653 / 663
页数:11
相关论文
共 50 条
  • [11] Teleoperation of an Ankle-Foot Prosthesis With a Wrist Exoskeleton
    Welker, Cara G.
    Chiu, Vincent L.
    Voloshina, Alexandra S.
    Collins, Steven H.
    Okamura, Allison M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (05) : 1714 - 1725
  • [12] An Ankle-Foot Prosthesis for Rock Climbing Augmentation
    Rogers, Emily A.
    Carney, Matthew E.
    Yeon, Seong Ho
    Clites, Tyler R.
    Solav, Dana
    Herr, Hugh M.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 : 41 - 51
  • [13] Evaluation of an articulated passive ankle-foot prosthesis
    Lathouwers, Elke
    Ampe, Toon
    Diaz, Maria Alejandra
    Meeusen, Romain
    De Pauw, Kevin
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [14] Active control of a powered ankle-foot prosthesis
    Ashwin Needham
    Andrzej Ordys
    Journal of Foot and Ankle Research, 7 (Suppl 1)
  • [15] Biomechanical design of a powered ankle-foot prosthesis
    Au, Samuel K.
    Weber, Jeff
    Herr, Hugh
    2007 IEEE 10TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, VOLS 1 AND 2, 2007, : 298 - 303
  • [16] DEVELOPMENT OF AN ANKLE-FOOT PROSTHESIS FOR PHYSICAL THERAPY
    Nickel, Eric
    Voss, Gregory
    Hansen, Andrew
    Koehler-McNicholas, Sara
    2019 DESIGN OF MEDICAL DEVICES CONFERENCE, 2019,
  • [17] A Robotic Ankle-Foot Prosthesis With Active Alignment
    LaPre, Andrew Kennedy
    Umberger, Brian R.
    Sup, Frank C.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (02):
  • [18] STIFFNESS ANALYSIS OF A SIMPLIFIED ANKLE-FOOT ORTHOSIS
    Swierski, Ethan
    Burke, Molly
    Arenas, Maria
    Bernat, Jessica
    Manzer, James
    Piovesan, Davide
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 5, 2020,
  • [19] Ankle-foot simulator development for testing ankle-foot orthoses
    Lai, Hung-Jen
    Yu, Chung-Huang
    Kao, Hung-Chan
    Chen, Wen-Chuan
    Chou, Chi-Wei
    Cheng, Cheng-Kung
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (06) : 623 - 629
  • [20] Design of a Quasi-Passive Ankle-Foot Orthosis with Customizable, Variable Stiffness
    Van Crey, Nikko
    Cavallin, Marcos
    Shepherd, Max
    Rouse, Elliott J.
    2023 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, ICORR, 2023,