The MyFlex-ζ Foot: A Variable Stiffness ESR Ankle-Foot Prosthesis

被引:0
|
作者
Tabucol, Johnnidel [1 ]
Kooiman, Vera G. M. [2 ,3 ]
Leopaldi, Marco [1 ]
Leijendekkers, Ruud [4 ,5 ]
Selleri, Giacomo [1 ]
Mellini, Marcello [1 ]
Verdonschot, Nico [6 ,7 ]
Oddsson, Magnus [8 ]
Carloni, Raffaella [9 ]
Zucchelli, Andrea [1 ]
Brugo, Tommaso M. [1 ]
机构
[1] Univ Bologna, Dept Ind Engn, I-40131 Bologna, Italy
[2] Radboud Univ Nijmegen, Med Ctr, Orthoped Res Lab, Dept Rehabil, NL-6500 HB Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Donders Inst Brain Cognit & Behav, NL-6500 HB Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Donders Inst Brain Cognit & Behav, Radboud Inst Hlth Sci, Orthoped Res Lab,Dept Rehabil,Med Ctr, NL-6500 HB Nijmegen, Netherlands
[5] Radboud Univ Nijmegen, Med Ctr, IQ Healthcare, NL-6500 HB Nijmegen, Netherlands
[6] Radboud Univ Nijmegen, Med Ctr, Orthoped Res Lab, NL-6500 HB Nijmegen, Netherlands
[7] Univ Twente, Fac Engn & Technol, Dept Biomech Engn, NL-7500 AE Enschede, Netherlands
[8] Ossur, IS-110 Reykjavik, Iceland
[9] Univ Groningen, Fac Sci & Engn, Dept Artificial Intelligence, Bernoulli Inst Math Comp Sci & Artificial Intelli, Groningen, Netherlands
关键词
Foot; Prosthetics; Legged locomotion; Ankle; Particle measurements; Force; Atmospheric measurements; Costs; Blades; Biomechanics; Amputation; biomechanical tests; prosthesis design; prosthetic feet; variable stiffness; TRANSTIBIAL AMPUTEES; POWERED KNEE; WALKING; AMPUTATION; DESIGN; ACTUATOR; FEET;
D O I
10.1109/TNSRE.2025.3534096
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most commercially available foot prostheses are passive ESR feet, which store and release energy to reduce metabolic costs and improve comfort but cannot adjust to varying walking conditions. In contrast, bionic feet adapt to different tasks but are hindered by high weight, power consumption, and cost. This paper presents MyFlex- zeta , an ESR foot with a variable stiffness system, as a compromise between these two categories. MyFlex- zeta adjusts stiffness by varying the sagittal-plane distance between two key points, altering force interactions within the prosthesis and affecting overall stiffness. Clinical tests with three transfemoral amputees evaluated stiffness variation across two sessions: the first subjective, where participants assessed stiffness settings during different tasks, and the second biomechanical, measuring performance parameters. Two participants selected different stiffness settings for various tasks, while the third, with limited perception of stiffness changes, showed less distinction in outcomes. Greater sagittal-plane rotation and higher energy absorption were observed in most tasks with more compliant settings, although one participant's results were limited due to selecting close stiffness settings. Overall, these findings suggest MyFlex- zeta offers adaptability and performance improvements over traditional ESR feet. With further actuation and control system development, MyFlex- zeta could mark significant progress in prosthesis technology.
引用
收藏
页码:653 / 663
页数:11
相关论文
共 50 条
  • [1] The Functionality Verification through Pilot Human Subject Testing of MyFlex-δ: An ESR Foot Prosthesis with Spherical Ankle Joint
    Tabucol, Johnnidel
    Kooiman, Vera Geertruida Maria
    Leopaldi, Marco
    Brugo, Tommaso Maria
    Leijendekkers, Ruud Adrianus
    Tagliabue, Gregorio
    Raveendranathan, Vishal
    Sotgiu, Eleonora
    Benincasa, Pietro
    Oddsson, Magnus
    Verdonschot, Nico
    Carloni, Raffaella
    Zucchelli, Andrea
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [2] The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness
    Shepherd, Max K.
    Rouse, Elliott J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (12) : 2375 - 2386
  • [3] Biologically Inspired Design and Development of a Variable Stiffness Powered Ankle-Foot Prosthesis
    Agboola-Dobson, Alexander
    Wei, Guowu
    Ren, Lei
    JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME, 2019, 11 (04):
  • [4] Powered ankle-foot prosthesis
    Biomechatronics Group, MIT Media Lab., Cambridge, MA 02139, United States
    IEEE Rob Autom Mag, 2008, 3 (52-59):
  • [5] Multiscale modeling of variable stiffness ankle-foot orthosis
    Redekop, S
    Meguid, SA
    Sagals, G
    Stranart, JC
    Parker, K
    COMPUTATIONAL FLUID AND SOLID MECHANICS 2003, VOLS 1 AND 2, PROCEEDINGS, 2003, : 1794 - 1796
  • [6] Design of a powered ankle-foot prosthesis with an adjustable stiffness toe joint
    She, Haotian
    Zhu, Jinying
    Tian, Ye
    Wang, Yanchao
    Huang, Qiang
    ADVANCED ROBOTICS, 2020, 34 (10) : 689 - 697
  • [7] The Difference Threshold of Ankle-Foot Prosthesis Stiffness for Persons with Transtibial Amputation
    Shepherd, Max K.
    Azocar, Alejandro F.
    Major, Matthew J.
    Rouse, Elliott J.
    2018 7TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB2018), 2018, : 100 - 104
  • [8] Design and characterization of a variable-stiffness ankle-foot orthosis
    Rong, Haochen
    Ramezani, Sepehr
    Ambro, Alex
    Lei, Chi Hou
    Choi, Hwan
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2024, 48 (06) : 720 - 726
  • [9] The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness (vol 25, pg 2375, 2017)
    Shepherd, Max K.
    Rouse, Elliott J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2018, 26 (03) : 716 - 716
  • [10] Design and Mechanical Characterization of a Variable Stiffness ESR Foot Prosthesis
    Tabucol, Johnnidel
    Leopaldi, Marco
    Brugo, Tommaso Maria
    Oddsson, Magnus
    Zucchelli, Andrea
    IEEE ACCESS, 2024, 12 : 97544 - 97556