The Functionality Verification through Pilot Human Subject Testing of MyFlex-δ: An ESR Foot Prosthesis with Spherical Ankle Joint

被引:4
|
作者
Tabucol, Johnnidel [1 ,2 ,3 ]
Kooiman, Vera Geertruida Maria [4 ,5 ]
Leopaldi, Marco [2 ]
Brugo, Tommaso Maria [1 ,2 ]
Leijendekkers, Ruud Adrianus [4 ,5 ,6 ]
Tagliabue, Gregorio [3 ]
Raveendranathan, Vishal [3 ]
Sotgiu, Eleonora [1 ]
Benincasa, Pietro [1 ]
Oddsson, Magnus [7 ]
Verdonschot, Nico [6 ,8 ]
Carloni, Raffaella [3 ]
Zucchelli, Andrea [1 ,2 ]
机构
[1] Univ Bologna, Dept Ind Engn, I-40131 Bologna, Italy
[2] Univ Bologna, Interdept Ctr Ind Res Adv Mech Engn Applicat & Ma, I-40131 Bologna, Italy
[3] Univ Groningen, Fac Sci & Engn, Bernoulli Inst Math Comp Sci & Artificial Intelli, NL-9747 AG Groningen, Netherlands
[4] Radboud Univ Nijmegen, Orthoped Res Lab, Med Ctr, NL-6525 GA Nijmegen, Netherlands
[5] Radboud Univ Nijmegen, Donders Inst Brain Cognit & Behav, Dept Rehabil, Med Ctr, NL-6525 GA Nijmegen, Netherlands
[6] Radboud Univ Nijmegen, Radboud Inst Hlth Sci, IQ Healthcare, Med Ctr, NL-6525 GA Nijmegen, Netherlands
[7] Ossur, Res & Dev, IS-110 Reykjavik, Iceland
[8] Univ Twente, Dept Biomech Engn, NL-7522 NB Enschede, Netherlands
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 09期
关键词
gait analyses; prosthetic foot; transtibial amputation; BELOW-KNEE AMPUTEES; BIOMECHANICAL ANALYSIS; ENERGY-STORAGE; GAIT ANALYSIS; FLEX-FOOT; COMPREHENSIVE ANALYSIS; MUSCLE COORDINATION; SOUND LIMB; SACH FOOT; PUSH-OFF;
D O I
10.3390/app12094575
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Most biomechanical research has focused on level-ground walking giving less attention to other conditions. As a result, most lower limb prosthesis studies have focused on sagittal plane movements. In this paper, an ESR foot is presented, of which five different stiffnesses were optimized for as many weight categories of users. It is characterized by a spherical ankle joint, with which, combined with the elastic elements, the authors wanted to create a prosthesis that gives the desired stiffness in the sagittal plane but at the same time, gives flexibility in the other planes to allow the adaptation of the foot prosthesis to the ground conditions. The ESR foot was preliminarily tested by participants with transfemoral amputation. After a brief familiarization with the device, each participant was asked to wear markers and to walk on a sensorized treadmill to measure their kinematics and kinetics. Then, each participant was asked to leave feedback via an evaluation questionnaire. The measurements and feedback allowed us to evaluate the performance of the prosthesis quantitatively and qualitatively. Although there were no significant improvements on the symmetry of the gait, due also to very limited familiarization time, the participants perceived an improvement brought by the spherical ankle joint.
引用
收藏
页数:30
相关论文
共 1 条
  • [1] The MyFlex-ζ Foot: A Variable Stiffness ESR Ankle-Foot Prosthesis
    Tabucol, Johnnidel
    Kooiman, Vera G. M.
    Leopaldi, Marco
    Leijendekkers, Ruud
    Selleri, Giacomo
    Mellini, Marcello
    Verdonschot, Nico
    Oddsson, Magnus
    Carloni, Raffaella
    Zucchelli, Andrea
    Brugo, Tommaso M.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2025, 33 : 653 - 663