Voltage Matrix Algorithm for Intraoperative Detection of Cochlear Implant Electrode Misplacement

被引:0
|
作者
Franke-Trieger, Annett [1 ]
Lailach, Susen [1 ]
Strahl, Stefan B. [2 ]
Murrmann, Katrin [1 ]
Schebsdat, Erik [3 ]
Neudert, Marcus [1 ]
Zahnert, Thomas [1 ]
机构
[1] Tech Univ Dresden, Dept Otorhinolaryngol Head & Neck Surg, Saxonian Cochlear Implant Ctr, Dresden, Germany
[2] MED EL Med Elect, Res & Dev, Innsbruck, Austria
[3] MED EL Elektromed Gerate Deutschland GmbH, Starnberg, Germany
关键词
Cochlear implant; Voltagematrix; Tip fold-over; Basal kinking; TIP FOLD-OVER; ARRAY; PANEL;
D O I
10.1159/000543264
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: To develop an algorithm, based on the voltage matrix, for detecting regular cochlear implant (CI) electrode position during the implantation procedure, tip fold-over or basal kinking for lateral-wall electrodes. The availability of an algorithm would be valuable in clinical routine, as incorrect positioning of the electrode array can potentially be recognized intraoperatively. Design: In this retrospective study, intraoperative voltage matrix and postoperative digital volume tomography of 525 CI recipients were analyzed. On the basis of these data an algorithm was developed for detecting various kinds of electrode misplacements. Results: Seven incorrect electrode positions, three tip fold (0.57%) and four basal kinking (0.76%) were detected. For detecting correct positioning, a sensitivity of 100%, a specificity of 83.3%, and a positive predictive value (PPV) of 99.8% were found. For detecting tip fold-over, a sensitivity of 100%, a specificity of 100%, and a PPV of 100% were found. For detecting basal kinking, a sensitivity of 66%, a specificity of 100%, and a PPV of 100% were determined. Conclusion: The algorithm was found to be an effective screening tool for detecting tip fold-over or basal kinking. (c) 2024 The Author(s). Published by S. Karger AG, Basel
引用
收藏
页数:11
相关论文
共 50 条
  • [31] New ultra-fast algorithm for cochlear implant misalignment detection
    Waldeck, Stephan
    Helal, Rania
    Al-Dhamari, Ibraheem
    Schmidt, Sandra
    von Falck, Christian
    Chapot, Rene
    Brockmann, Marc
    Overhoff, Daniel
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151
  • [32] Electrode array misplacement into the superior semicircular canal: As a rare complication of cochlear implantation
    Sun, Jia-Qiang
    Sun, Jing-Wu
    Hou, Xiao-Yan
    Bie, Yuan-Zhi
    Chen, Jian-Wen
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2014, 78 (09) : 1537 - 1540
  • [33] Speech Performance Following Intraoperative Correction of Cochlear Implant Electrode Array Tip Fold-Overs
    Smetak, Miriam R.
    Shew, Matthew A.
    Varghese, Jordan
    Durakovic, Nedim
    Wick, Cameron C.
    Buchman, Craig A.
    Herzog, Jacques A.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2025,
  • [34] The impact of electrode type on intraoperative and postoperative telemetry measures in cochlear implant using different surgical technique
    Hamada S.
    Omara A.
    Sefein I.K.
    Younes A.
    The Egyptian Journal of Otolaryngology, 2016, 32 (4) : 264 - 270
  • [35] Intraoperative transimpedance and spread of excitation profile correlations with a lateral-wall cochlear implant electrode array
    Soderqvist, Samuel
    Lamminmaki, Satu
    Aarnisalo, Antti
    Hirvonen, Timo
    Sinkkonen, Saku T.
    Sivonen, Ville
    HEARING RESEARCH, 2021, 405
  • [36] Utility of Intraoperative Radiographs in Pediatric Cochlear Implant Surgery
    Savoca, Emily
    Smith, Brandon
    Shaffer, Amber D.
    Kitsko, Dennis
    Chi, David
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2023, 169 (05) : 1282 - 1289
  • [37] Intricacies of Cochlear Implant Electrode Design and Their Limitations
    Gadre, Arun K.
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2018, 14 (03): : 375 - 375
  • [38] Surface patterning of cochlear implant electrode arrays
    Fadeeva, E.
    Linke, I
    Lenarz, T.
    Chichkov, B.
    Paasche, G.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [39] A COMPLEX CASE OF COCHLEAR IMPLANT ELECTRODE PLACEMENT
    LEVINE, SC
    AMERICAN JOURNAL OF OTOLOGY, 1989, 10 (06): : 477 - 480
  • [40] The cochlear implant electrode-pitch function
    Baumann, U
    Nobbe, A
    HEARING RESEARCH, 2006, 213 (1-2) : 34 - 42