The effect of sampling window size on topographical maps of foveal cone density

被引:0
|
作者
Warr, Emma [1 ]
Grieshop, Jenna [1 ,2 ,3 ]
Cooper, Robert F. [1 ,2 ,3 ]
Carroll, Joseph [1 ,2 ,3 ,4 ]
机构
[1] Med Coll Wisconsin, Dept Ophthalmol & Visual Sci, Milwaukee, WI 53226 USA
[2] Marquette Univ, Joint Dept Biomed Engn, Milwaukee, WI 53233 USA
[3] Med Coll Wisconsin, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Dept Cell Biol Neurobiol & Anat, Milwaukee, WI 53226 USA
来源
关键词
fovea; cone density; cone spacing; adaptive optics; retina; PHOTORECEPTOR PACKING DENSITY; VARIABILITY; ROD; ECCENTRICITY; FIXATION; METRICS; IMAGES;
D O I
10.3389/fopht.2024.1348950
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To characterize the effect of sampling window size on maps of foveal cone density derived from adaptive optics scanning light ophthalmoscope (AOSLO) images of the cone mosaic. Methods: Forty-four AOSLO-derived montages of the foveal cone mosaic (300 x 300 mu m) were used for this study (from 44 individuals with normal vision). Cone photoreceptor coordinates were semi-automatically identified by one experienced grader. From these coordinates, cone density matrices across each foveal montage were derived using 10 different sampling window sizes containing 5, 10, 15, 20, 40, 60, 80, 100, 150, or 200 cones. For all 440 density matrices, we extracted the location and value of peak cone density (PCD), the cone density centroid (CDC) location, and cone density at the CDC. Results: Across all window sizes, PCD values were larger than those extracted at the CDC location, though the difference between these density values decreased as the sampling window size increased (p<0.0001). Overall, both PCD (r=-0.8099, p=0.0045) and density at the CDC (r=-0.7596, p=0.0108) decreased with increasing sampling window size. This reduction was more pronounced for PCD, with a 27.8% lower PCD value on average when using the 200-cone versus the 5-cone window (compared to only a 3.5% reduction for density at the CDC between these same window sizes). While the PCD and CDC locations did not occur at the same location within a given montage, there was no significant relationship between this PCD-CDC offset and sampling window size (p=0.8919). The CDC location was less variable across sampling windows, with an average per-participant 95% confidence ellipse area across the 10 window sizes of 47.56<mu>m(2) (compared to 844.10 mu m(2) for the PCD location, p<0.0001). Conclusion: CDC metrics appear more stable across varying sampling window sizes than PCD metrics. Understanding how density values change according to the method used to sample the cone mosaic may facilitate comparing cone density data across different studies.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The effect of sampling window size on topographical maps of foveal cone density
    Warr, Emma
    Heitkotter, Heather
    Cooper, Robert F.
    Carroll, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [2] Influence of sampling window size and orientation on parafoveal cone packing density
    Lombardo, Marco
    Serrao, Sebastiano
    Ducoli, Pietro
    Lombardo, Giuseppe
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (08): : 1318 - 1331
  • [3] Assessing the effect of TYR hypomorphic alleles on foveal cone density
    Warr, Emma
    Grieshop, Jenna
    Zacharias, Serena
    Adhan, Iniya
    Carroll, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [4] Assessing the relationship between foveal cone density, foveal ONL thickness and foveal morphology
    Zacharias, Serena
    Heitkotter, Heather
    Adhan, Iniya
    Walesa, Ashleigh
    Grieshop, Jenna
    Carroll, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [5] Intervisit Reproducibility of Foveal Cone Density Metrics
    Adhan, Iniya
    Warr, Emma
    Grieshop, Jenna
    Kreis, Joseph
    Nikezic, Danica
    Walesa, Ashleigh
    Hemsworth, Katherine
    Cooper, Robert F.
    Carroll, Joseph
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (06):
  • [6] DENSITY OF FOVEAL CONE PIGMENTS AT OLDER AGE
    KEUNEN, JEE
    VANNORREN, D
    VANMEEL, GJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1987, 28 (06) : 985 - 991
  • [7] Effect of shape and size of sampling window on the determination of average length, intensity and density of trace discontinuity
    Kamali, A.
    Shahriar, K.
    Sharifzadeh, M.
    Aalianvari, A.
    Esmaeilzadeh, A.
    ROCK MECHANICS AND ROCK ENGINEERING: FROM THE PAST TO THE FUTURE, VOL 2, 2016, : 1073 - 1078
  • [8] Assessing interocular symmetry of foveal cone density
    Cava, Jenna
    Mastey, Rebecca
    Allphin, Mitchell
    Cooper, Robert F.
    Carroll, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [9] Investigating the relationship between foveal cone density and its interaction with foveal crowding
    Prahalad, Krishnamachari
    Clark, Ashley Michelle
    Moon, Benjamin
    Roorda, Austin
    Tiruveedhula, Pavan
    Harmening, Wolf
    Gutnikov, Aleksandr
    Jenks, Samantha K.
    Kapisthalam, Sanjana
    Rucci, Michele
    Rolland, Jannick P.
    Poletti, Martina
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [10] FOVEAL AREA, POSITION, AND INVIVO DENSITY OF CONE PIGMENTS
    BAKER, HD
    MAY, JG
    KUYK, TK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1979, : 31 - 31