Second dimension temperature programming system for comprehensive two-dimensional gas chromatography with true temperature control

被引:3
|
作者
Chow, Hei Yin J. [1 ]
Gorecki, Tadeusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
来源
基金
加拿大自然科学与工程研究理事会;
关键词
Comprehensive two-dimensional gas; chromatography; Second dimension temperature programming; Peak capacity; Differential thermocouple; Arduino; MODULATOR; IMPACT;
D O I
10.1016/j.jcoa.2022.100062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A proof-of-concept second dimension (2 2 D) temperature programming system for comprehensive two-dimensional gas chromatography (GC x GC) with true temperature control is introduced and its performance characterized. The 2 D temperature programming system utilized a commercial stainless-steel capillary column that was resistively heated and controlled using an Arduino UNO microcontroller. Temperature measurement was accomplished using a differential thermocouple system attached to the 2 D column. Diesel was injected in triplicate to compare the reproducibility of the GC x GC system without additional 2 D heating, with 2 D temperature programming, and with a constant offset, all accomplished using the 2 D temperature programming system. Relative standard deviations for the 2 D temperature programming were 0.02%, 0.49% and 1.2% for the first dimension (1 1 D) retention time, 2 D retention time, and peak area, respectively. The estimated 2 D peak capacity improved by 48% with 2 D temperature programming compared to the separation without additional 2 D heating.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comprehensive two-dimensional liquid chromatography applying two parallel columns in the second dimension
    Francois, Isabelle
    de Villiers, Andre
    Tienpont, Bart
    David, Frank
    Sandra, Pat
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1178 (1-2) : 33 - 42
  • [22] High temperature diaphragm valve-based comprehensive two-dimensional gas chromatography
    Freye, Chris E.
    Mu, Lan
    Synovec, Robert E.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1424 : 127 - 133
  • [23] Comprehensive Two-Dimensional Gas Chromatography
    Ryan, Danielle
    Marriott, Philip
    ADVANCES IN CHROMATOGRAPHY, VOL 46, 2008, 46 : 451 - 467
  • [24] Comprehensive two-dimensional gas chromatography
    Hinshaw, JV
    LC GC EUROPE, 2004, 17 (02) : 86 - +
  • [25] Comprehensive two-dimensional gas chromatography
    Hinshaw, JV
    LC GC NORTH AMERICA, 2004, 22 (01) : 32 - +
  • [26] Comprehensive two-dimensional gas chromatography
    Ryan, D
    Marriott, P
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (03) : 295 - 297
  • [27] Comprehensive two-dimensional gas chromatography
    Danielle Ryan
    Philip Marriott
    Analytical and Bioanalytical Chemistry, 2003, 376 : 295 - 297
  • [28] Method to determine the true modulation ratio for comprehensive two-dimensional gas chromatography
    Pinkerton, David K.
    Parsons, Brendon A.
    Synovec, Robert E.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1476 : 114 - 123
  • [29] Pressure Tuning of First Dimension Columns in Comprehensive Two-Dimensional Gas Chromatography
    Sharif, Khan M.
    Kulsing, Chadin
    Marriott, Philip J.
    ANALYTICAL CHEMISTRY, 2016, 88 (18) : 9087 - 9094
  • [30] Surface fitting for calculating the second dimension retention index in comprehensive two-dimensional gas chromatography mass spectrometry
    Prodhan, Md Aminul Islam
    Yin, Xinmin
    Kim, Seongho
    McClain, Craig
    Zhang, Xiang
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1539 : 62 - 70