Pressure Tuning of First Dimension Columns in Comprehensive Two-Dimensional Gas Chromatography

被引:14
|
作者
Sharif, Khan M. [1 ]
Kulsing, Chadin [1 ]
Marriott, Philip J. [1 ]
机构
[1] Monash Univ, Sch Chem, Australian Ctr Res Separat Sci, Wellington Rd, Clayton, Vic 3168, Australia
基金
澳大利亚研究理事会;
关键词
HIGH-SPEED GC; TUNABLE SELECTIVITY; PROGRAMMABLE CONTROL; SEPARATION; OPTIMIZATION; TEMPERATURE; QUANTIFICATION; ENSEMBLES; MODEL;
D O I
10.1021/acs.analchem.6b02017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The experimental approach and mechanism of pressure tuning (PT) are introduced for the first stage of a comprehensive two-dimensional gas chromatography (GC x GC) separation. The PT-GC x GC system incorporates a first dimension (D-1) coupled column ensemble Comprising a pair of D-1 columns (D-1(1) and D-1(2)) connected via a niicrofluidic splitter device, allowing variable decompression of carrier gas across each D-1 column, and a conventional D-2 narrow bore column. By variation of junction pressure between,the D-1(1) and D-1(2) columns, tunable total ID retentions of analytes are readily derived. Separations of a standard mixture comprising a number of different chemical classes (including alkanes, monoaromatics, alcohols, aldehydes, ketones, and esters) and Australian tea tree oil (TTO) were studied as practical examples of the PT-GC x GC system application: This illustrated the change of analyte retention time with experimental conditions depending on void time and retention on the different coumns. In addition to void time, change, variation of carrier gas relative decompression in the D-1 ensemble leads to tunable contribution of the (1)D1/D-1(2) Columns that changes apparent polarity and selectivity of the ensemble. The resulting changes in D-1 elution order further altered elution temperature and thus retention of each analyte on the D-2 column in temperature-programmed GC x GC. 2D orthogonality measurements were then conducted to evaluate overall separation performance under application of different D-1 junction pressure. As a result, distribution and selectivity of particular target compounds, monoterpenes, sesquiterpenes, and oxygenated terpenes in 2D Space, and thus orthogonality, could be adequately tuned. This indicates the potential of PT-GC x GC to be applicable for practical sample separation and provides a general approach to tune selectivity of target compounds.
引用
收藏
页码:9087 / 9094
页数:8
相关论文
共 50 条
  • [1] Second dimension column ensemble pressure tuning in comprehensive two-dimensional gas chromatography
    Sharif, Khan M.
    Kulsing, Chadin
    da Silva Junior, Ademario I.
    Marriott, Philip J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2018, 1536 : 39 - 49
  • [2] Pressure Tuning: Increasing the Flexibility of Comprehensive Two-Dimensional Gas Chromatography
    Khan, Mohammad Sharif
    Marriott, Philip John
    [J]. LC GC EUROPE, 2018, 31 (08) : 422 - 426
  • [3] Pressure Tuning: Increasing the Flexibility of Comprehensive Two-Dimensional Gas Chromatography
    Khan, Mohammed Sharif
    Marriott, Philip John
    [J]. LC GC NORTH AMERICA, 2019, 37 (03) : 200 - +
  • [4] Evaluation of Gas Chromatography Columns with Radially Elongated Pillars as Second-Dimension Columns in Comprehensive Two-Dimensional Gas Chromatography
    Meziani, Amel
    Verloy, Sandrien
    Ferroukhi, Ouassila
    Roca, Sebastien
    Curat, Aurelien
    Tisse, Severine
    Peulon-Agasse, Valerie
    Gardeniers, Han
    Desmet, Gert
    Cardinael, Pascal
    [J]. ANALYTICAL CHEMISTRY, 2022, 94 (41) : 14126 - 14134
  • [5] Macroporous polymer monoliths as second dimension columns in comprehensive two-dimensional gas chromatography: A feasibility study
    Peroni, Daniela
    Vonk, Rudy J.
    van Egmond, Wil
    Janssen, Hans-Gerd
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1268 : 139 - 149
  • [6] Comprehensive two-dimensional liquid chromatography applying two parallel columns in the second dimension
    Francois, Isabelle
    de Villiers, Andre
    Tienpont, Bart
    David, Frank
    Sandra, Pat
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1178 (1-2) : 33 - 42
  • [7] Tunable secondary dimension selectivity in comprehensive two-dimensional gas chromatography
    Mommers, John
    Pluimakers, Giulia
    Knooren, Jeroen
    Dutriez, Thomas
    van der Wal, Sjoerd
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1297 : 179 - 185
  • [8] Temperature Programming of the Second Dimension in Comprehensive Two-Dimensional Gas Chromatography
    Chow, Hei-Yin J.
    Gorecki, Tadeusz
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (16) : 8207 - 8211
  • [9] A New Dimension in Separation Science: Comprehensive Two-Dimensional Gas Chromatography
    Meinert, Cornelia
    Meierhenrich, Uwe J.
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (42) : 10460 - 10470
  • [10] Comprehensive Two-Dimensional Gas Chromatography
    Ryan, Danielle
    Marriott, Philip
    [J]. ADVANCES IN CHROMATOGRAPHY, VOL 46, 2008, 46 : 451 - 467