Transcritical R744 Supermarket Refrigeration System Integrated with a Heat-Driven Ejector Chiller

被引:0
|
作者
Sengupta, Ayan [1 ]
Gullo, Paride [2 ]
Khorshidi, Vahid [3 ]
Dasgupta, Mani Sankar [1 ]
机构
[1] BITS, Dept Mech Engn, Smart Bldg Lab, Pilani 333031, Rajasthan, India
[2] Univ Southern Denmark SDU, Inst Mech & Elect Engn, Alsion 2, DK-6400 Sonderborg, Denmark
[3] Danfoss AS, Nordborgvej 81, DK-6430 Nordborg, Denmark
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 06期
关键词
supermarket; R744; R717; R718; R600a; refrigeration; subcooling; ejector; waste heat; parallel compression; PERFORMANCE; ENERGY;
D O I
10.3390/app15062955
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The subcooling potential of a novel R717-based waste heat-driven multi-ejector chiller (HEC) integrated with an R744 refrigeration system was evaluated for use in supermarkets. The performance was compared with an R744 refrigeration system coupled to R718- and R600a-based HECs, an R744 system equipped with parallel compression (PC), and a standard R744 booster system (CB) in various warm and hot climatic locations. Integration of the R717-based HEC was found to improve the coefficient of performance by 3.7% at 27 degrees C to 12.1% at 45 degrees C compared to the R718, and by 1.6% at 27 degrees C to 7.6% at 45 degrees C compared to the R600a-based system. The energy-saving potential of the R717 system (6.2% to 9.4%) was also found to be higher than that of the R718 (0.7% to 2.8%) and R600a systems (2.5% to 6.6%). The use of the existing high-pressure controllers of the CB system was found to impose a relatively lower penalty on the system performance compared to the controllers of the PC system. Although the integration of the R718 system incurred a significantly lower additional investment, the recovery time of the R600a-based HEC (2.3-4.8 years) was found to be the shortest.
引用
收藏
页数:27
相关论文
共 50 条
  • [31] MEASUREMENT OF OIL IN CIRCULATION IN TRANSCRITICAL R744 SYSTEMS USING TWO-PHASE EJECTOR
    Zhu, Jingwei
    Botticella, Francesco
    Elbel, Stefan
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 247 - 254
  • [32] Performance Investigation of a Multi-Ejector R744 Heat Pump
    Singh, Simarpreet
    Reddy, Amshith
    Prakash, Maiya P.
    Banasiak, Krzysztof
    Hafner, Armin
    Neksa, Petter
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 839 - 846
  • [33] Experimental evaluation of a cascade refrigeration system with the natural refrigerants R290/R744, R1270/R744 and R600a/R744
    Cabello, R.
    Sanchez, D.
    Andreu-Nacher, A.
    Llopis, R.
    Nebot-Andres, L.
    Calleja-Anta, D.
    Vidan-Falomir, F.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 616 - 626
  • [34] Two-phase flow visualisation in the R744 vapour ejector for refrigeration systems
    Palacz, Michal
    Bodys, Jakub
    Haida, Michal
    Smolka, Jacek
    Nowak, Andrzej J.
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [35] Recent Advances in Transcritical CO2 (R744) Heat Pump System: A Review
    Rony, Rajib Uddin
    Yang, Huojun
    Krishnan, Sumathy
    Song, Jongchul
    ENERGIES, 2019, 12 (03)
  • [36] Performance analysis of a new transcritical R744 refrigeration cycle with expander-mechanical overheating
    Sun, Dahan
    Fei, Teng
    Liu, Zekuan
    Xu, Jing
    Qin, Jiang
    APPLIED THERMAL ENGINEERING, 2023, 218
  • [37] R744 REFRIGERATION SYSTEM CONFIGURATIONS FOR SUPERMARKETS IN WARM CLIMATES
    Hafner, A.
    Hemmingsen, A. K.
    Van de Ven, A.
    3RD IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2014, 2014 (01): : 125 - 133
  • [38] Comprehensive experimental performance study on a small-capacity transcritical R744 vapour-compression refrigeration unit equipped with an innovative ejector
    Gullo, Paride
    Birkelund, Michael
    Kriezi, Ekaterini E.
    Kaern, Martin Ryhl
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 152 : 192 - 203
  • [39] EXPERIENCE WITH EJECTORS IMPLEMENTED IN A R744 BOOSTER SYSTEM OPERATING IN A SUPERMARKET
    Schoenenberger, J.
    Hafner, A.
    Banasiak, K.
    Girotto, S.
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 755 - 765
  • [40] Thermodynamic performance evaluation of a cascade refrigeration system with mixed refrigerants: R744/R1270, R744/R717 and R744/RE170
    Parolin Massuchetto, Luiz Henrique
    Correa do Nascimento, Raiza Barcelos
    Rocha de Carvalho, Stella Maia
    de Araujo, Hugo Valenca
    Hallak d'Angelo, Jose Vicente
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 : 201 - 212