Transcritical R744 Supermarket Refrigeration System Integrated with a Heat-Driven Ejector Chiller

被引:0
|
作者
Sengupta, Ayan [1 ]
Gullo, Paride [2 ]
Khorshidi, Vahid [3 ]
Dasgupta, Mani Sankar [1 ]
机构
[1] BITS, Dept Mech Engn, Smart Bldg Lab, Pilani 333031, Rajasthan, India
[2] Univ Southern Denmark SDU, Inst Mech & Elect Engn, Alsion 2, DK-6400 Sonderborg, Denmark
[3] Danfoss AS, Nordborgvej 81, DK-6430 Nordborg, Denmark
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 06期
关键词
supermarket; R744; R717; R718; R600a; refrigeration; subcooling; ejector; waste heat; parallel compression; PERFORMANCE; ENERGY;
D O I
10.3390/app15062955
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The subcooling potential of a novel R717-based waste heat-driven multi-ejector chiller (HEC) integrated with an R744 refrigeration system was evaluated for use in supermarkets. The performance was compared with an R744 refrigeration system coupled to R718- and R600a-based HECs, an R744 system equipped with parallel compression (PC), and a standard R744 booster system (CB) in various warm and hot climatic locations. Integration of the R717-based HEC was found to improve the coefficient of performance by 3.7% at 27 degrees C to 12.1% at 45 degrees C compared to the R718, and by 1.6% at 27 degrees C to 7.6% at 45 degrees C compared to the R600a-based system. The energy-saving potential of the R717 system (6.2% to 9.4%) was also found to be higher than that of the R718 (0.7% to 2.8%) and R600a systems (2.5% to 6.6%). The use of the existing high-pressure controllers of the CB system was found to impose a relatively lower penalty on the system performance compared to the controllers of the PC system. Although the integration of the R718 system incurred a significantly lower additional investment, the recovery time of the R600a-based HEC (2.3-4.8 years) was found to be the shortest.
引用
收藏
页数:27
相关论文
共 50 条
  • [21] Impact and quantification of various individual thermodynamic improvements for transcritical R744 supermarket refrigeration systems based on advanced exergy analysis
    Gullo, Paride
    ENERGY CONVERSION AND MANAGEMENT, 2021, 229
  • [22] VORTEX CONTROL FOR MOTIVE FLOW RATE MODULATION OF TRANSCRITICAL R744 EJECTOR SYSTEMS
    Zhu, Jingwei
    Elbel, Stefan
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 263 - 270
  • [23] Experimental investigation into the influence of vortex control on transcritical R744 ejector and cycle performance
    Zhu, Jingwei
    Elbel, Stefan
    APPLIED THERMAL ENGINEERING, 2020, 164
  • [24] A computational model of a transcritical R744 ejector based on a homogeneous real fluid approach
    Smolka, Jacek
    Bulinski, Zbigniew
    Fic, Adam
    Nowak, Andrzej J.
    Banasiak, Krzysztof
    Hafner, Armin
    APPLIED MATHEMATICAL MODELLING, 2013, 37 (03) : 1208 - 1224
  • [25] TEST FACILITY FOR A MULTIEJECTOR R744 REFRIGERATION SYSTEM
    Banasiak, K.
    Hafner, A.
    Haddal, O.
    Eikevik, T.
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 783 - 790
  • [26] ANALYSIS OF R744 REFRIGERATION SYSTEM WITH LIQUID EJECTORS
    Singh, Simarpreet
    Reddy, Amshith
    Prakash, Maiya M.
    Banasiak, Krzysztof
    Hafner, Armin
    Neksa, Petter
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 891 - 898
  • [27] An Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHC
    Barroca, Pierre
    Hafner, Armin
    Verlaat, Bart
    Petagna, Paolo
    Hulek, Wojciech
    Zwalinski, Lukasz
    Hanf, Pierre
    Battistin, Michele
    Davoine, Loic
    Teixeira, Daniella
    APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [28] R744 EJECTOR SUPPORTED PARALLEL VAPOUR COMPRESSION SYSTEM
    Hafner, A.
    Schoenenberger, J.
    Banasiak, K.
    Girotto, S.
    3RD IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2014, 2014 (01): : 134 - 141
  • [29] Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation
    Elbel, Stefan
    Hrnjak, Pega
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (03): : 411 - 422
  • [30] Preliminary experimental investigation on a transcritical R744 condensing unit using the novel PWM ejector
    Gullo, Paride
    Kaern, Martin Ryhl
    Birkelund, Michael
    Kriezi, Ekaterini E.
    14TH IIR GUSTAV-LORENTZEN CONFERENCE ON NATURAL FLUIDS, 2020, : 363 - 368