Optimizing Stem Length in Conversion Total Hip Arthroplasty: An Expanded Finite Element Analysis

被引:0
|
作者
Shimasaki, Koshiro [1 ]
Nishino, Tomofumi [1 ]
Yoshizawa, Tomohiro [1 ]
Watanabe, Ryunosuke [1 ]
Hirose, Fumi [1 ]
Yasunaga, Shota [1 ]
Mishima, Hajime [1 ]
机构
[1] Univ Tsukuba, Inst Med, Dept Orthopaed Surg, 1-1-1 Tennodai, Tsukuba 3058575, Japan
关键词
conversion total hip arthroplasty (cTHA); finite element analysis (FEA); stress concentration; periprosthetic fracture; stem length; FAILED INTERNAL-FIXATION; INTERTROCHANTERIC FRACTURE; PERIPROSTHETIC FRACTURES; CORTICAL DEFECTS; FEMORAL-NECK; SALVAGE; FEMUR; COMPLICATIONS; STRESS; BIOMECHANICS;
D O I
10.3390/jcm14041141
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Stress concentration around distal screw-removal holes confers a major risk for periprosthetic fractures following conversion total hip arthroplasty (cTHA) for intertrochanteric femoral fractures. Optimal stem-selection criteria and guidelines for cTHA can improve clinical outcomes. We determined the influence of the cementless stem length on the stress distribution around distal screw-removal holes. Methods: For the finite element analysis, institutional data from preoperative CT scans of contralateral femurs of patients who underwent THA were used. To replicate the post-nail-removal state, we used 3D registration of standard triangulated language data of the intramedullary nail as an unused material to simulate distal screw-removal holes, located 135 mm from the proximal end of the intramedullary nail. Cementless stems of 130, 140, 150, and 160 mm were individually registered using STL data, and cTHA models were constructed accordingly. Using simulations under load conditions representing normal walking and stair climbing, the mean and maximum equivalent stress values around the distal screw-removal holes were calculated. For multiple comparisons, repeated-measures ANOVA with Bonferroni correction was employed. Results: Compared to the 130 mm stem, the 150 mm and 160 mm stems similarly reduced the maximum equivalent stress around the distal screw-removal holes, although the 140 mm stem showed no significant difference with other stems. Conclusions: A >= 150 mm stem length reliably mitigated stress concentration around distal screw-removal holes post-cTHA; it is the optimal choice for balancing effectiveness and risk of complications and may contribute to improved long-term clinical outcomes. This study provides practical evidence for stem selection in cTHA and offers valuable insights for future treatment guidelines.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Axisymmetric finite element analysis of a debonded total hip stem with an unsupported distal tip
    Norman, T.L.
    Saligrama, V.C.
    Hustosky, K.T.
    Gruen, T.A.
    Blaha, J.D.
    Journal of Biomechanical Engineering, 1996, 118 (03): : 399 - 404
  • [32] Axisymmetric finite element analysis of a debonded total hip stem with an unsupported distal tip
    Norman, TL
    Saligrama, VC
    Hustosky, KT
    Gruen, TA
    Blaha, JD
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 399 - 404
  • [33] Finite Element Analysis of Stress Distribution of Cemented Stem After Total Hip Replacement
    Zheng, Xiao-Wen
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2765 - 2768
  • [34] Can Arthroplasty Stem Influence Outcome: A Randomized Controlled Trial of Stem Length in Cemented Total Hip Arthroplasty
    Gaston, Paul
    Clement, Nicholas D.
    Ohly, Nichiolas E.
    Macpherson, Gavin J.
    Hamilton, David F.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (09): : 1793 - 1801
  • [35] Primary vs Conversion Total Hip Arthroplasty: A Cost Analysis
    Chin, Garwin
    Wright, David J.
    Snir, Nimrod
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2016, 31 (02): : 362 - 367
  • [36] 'Pre-launch' finite element analysis of a short-stem total hip arthroplasty system consisting of two implant types
    Lerch, Matthias
    Windhagen, Henning
    Kurtz, Agnes-Elisabeth
    Budde, Stefan
    Behrens, Bernd-Arno
    Bouguecha, Anas
    Almohallami, Amer
    CLINICAL BIOMECHANICS, 2019, 61 : 31 - 37
  • [37] Total hip arthroplasty by using a cementless ultrashort stem: A subject-specific finite element analysis for a young patient clinical case
    Epasto, Gabriella
    Foti, Albina
    Guglielmino, Eugenio
    Rosa, Michele A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (07) : 757 - 766
  • [38] Conversion of hip resurfacing to total hip arthroplasty: is the outcome closer to primary or revision total hip arthroplasty?
    Mutschler, Marion
    Massazza, Allegra
    Antoniadis, Alexander
    Palazzuolo, Michele
    Wegrzyn, Julien
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (08)
  • [39] The effect of stem length on femoral component positioning in canine total hip arthroplasty
    Dearmin, MG
    Schulz, KS
    VETERINARY SURGERY, 2004, 33 (03) : 272 - 278
  • [40] The impact of reducing the femoral stem length in total hip arthroplasty during gait
    Anatole Vilhelm Wiik
    Adeel Aqil
    Bilal Al-Obaidi
    Mads Brevadt
    Justin Peter Cobb
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1993 - 2000