Optimizing Stem Length in Conversion Total Hip Arthroplasty: An Expanded Finite Element Analysis

被引:0
|
作者
Shimasaki, Koshiro [1 ]
Nishino, Tomofumi [1 ]
Yoshizawa, Tomohiro [1 ]
Watanabe, Ryunosuke [1 ]
Hirose, Fumi [1 ]
Yasunaga, Shota [1 ]
Mishima, Hajime [1 ]
机构
[1] Univ Tsukuba, Inst Med, Dept Orthopaed Surg, 1-1-1 Tennodai, Tsukuba 3058575, Japan
关键词
conversion total hip arthroplasty (cTHA); finite element analysis (FEA); stress concentration; periprosthetic fracture; stem length; FAILED INTERNAL-FIXATION; INTERTROCHANTERIC FRACTURE; PERIPROSTHETIC FRACTURES; CORTICAL DEFECTS; FEMORAL-NECK; SALVAGE; FEMUR; COMPLICATIONS; STRESS; BIOMECHANICS;
D O I
10.3390/jcm14041141
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Stress concentration around distal screw-removal holes confers a major risk for periprosthetic fractures following conversion total hip arthroplasty (cTHA) for intertrochanteric femoral fractures. Optimal stem-selection criteria and guidelines for cTHA can improve clinical outcomes. We determined the influence of the cementless stem length on the stress distribution around distal screw-removal holes. Methods: For the finite element analysis, institutional data from preoperative CT scans of contralateral femurs of patients who underwent THA were used. To replicate the post-nail-removal state, we used 3D registration of standard triangulated language data of the intramedullary nail as an unused material to simulate distal screw-removal holes, located 135 mm from the proximal end of the intramedullary nail. Cementless stems of 130, 140, 150, and 160 mm were individually registered using STL data, and cTHA models were constructed accordingly. Using simulations under load conditions representing normal walking and stair climbing, the mean and maximum equivalent stress values around the distal screw-removal holes were calculated. For multiple comparisons, repeated-measures ANOVA with Bonferroni correction was employed. Results: Compared to the 130 mm stem, the 150 mm and 160 mm stems similarly reduced the maximum equivalent stress around the distal screw-removal holes, although the 140 mm stem showed no significant difference with other stems. Conclusions: A >= 150 mm stem length reliably mitigated stress concentration around distal screw-removal holes post-cTHA; it is the optimal choice for balancing effectiveness and risk of complications and may contribute to improved long-term clinical outcomes. This study provides practical evidence for stem selection in cTHA and offers valuable insights for future treatment guidelines.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Finite element analysis of hip stem designs
    Bennett, David
    Goswami, Tarun
    MATERIALS & DESIGN, 2008, 29 (01) : 45 - 60
  • [22] Modular femoral neck failure after revision of a total hip arthroplasty: a finite element analysis
    Zajc, Jan
    Predan, Jozef
    Gubeljak, Nenad
    Molicnik, Andrej
    Fokter, Samo K.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (03): : 717 - 723
  • [23] Abductor weakness and stresses around acetabular components of total hip arthroplasty: a finite element analysis
    A. G. Sutherland
    S. D’Arcy
    D Smart
    G. P. Ashcroft
    International Orthopaedics, 1999, 23 : 275 - 278
  • [24] Finite Element Analysis of Optimal Positioning of Femoral Osteotomy in Total Hip Arthroplasty With Subtrochanteric Shortening
    Takahashi, Daisuke
    Noyama, Yoshihiro
    Shimizu, Tomohiro
    Terkawi, Mohamad Alaa
    Iwasaki, Norimasa
    ARTHROPLASTY TODAY, 2022, 14 : 105 - 109
  • [25] Femoral Stress Changes after Total Hip Arthroplasty with the Ribbed Prosthesis: A Finite Element Analysis
    Luo, Changqi
    Wu, Xiang-Dong
    Wan, Yifei
    Liao, Junyi
    Cheng, Qiang
    Tian, Mian
    Bai, Zhibiao
    Huang, Wei
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [26] Modular femoral neck failure after revision of a total hip arthroplasty: a finite element analysis
    Jan Zajc
    Jožef Predan
    Nenad Gubeljak
    Andrej Moličnik
    Samo K. Fokter
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 717 - 723
  • [27] How does bicycling affect the longevity of Total Hip Arthroplasty? A finite element wear analysis
    Toh, Shawn Ming Song
    Ashkanfar, Ariyan
    English, Russell
    Rothwell, Glynn
    Langton, David J.
    Joyce, Thomas J.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 139
  • [28] Abductor weakness and stresses around acetabular components of total hip arthroplasty: a finite element analysis
    Sutherland, AG
    D'Arcy, S
    Smart, D
    Ashcroft, GP
    INTERNATIONAL ORTHOPAEDICS, 1999, 23 (05) : 275 - 278
  • [29] Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis
    Ding, Zhentao
    Wang, Jun
    Wang, Yanhua
    Zhang, Xiaomeng
    Huan, Yong
    Zhang, Dianying
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [30] Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis
    Zhentao Ding
    Jun Wang
    Yanhua Wang
    Xiaomeng Zhang
    Yong Huan
    Dianying Zhang
    BMC Musculoskeletal Disorders, 24