Synthesized V7 QRS Amplitude and Oversensing Episodes in Patients With Subcutaneous Implantable Cardioverter-Defibrillators

被引:0
|
作者
Okajima, Takashi [1 ,2 ]
Ishikawa, Shinji [1 ]
Yanagisawa, Satoshi [2 ,3 ]
Okamoto, Takayuki [1 ]
Uemura, Yusuke [1 ]
Takemoto, Kenji [1 ]
Inden, Yasuya [2 ]
Murohara, Toyoaki [2 ]
Watarai, Masato [1 ]
机构
[1] Anjo Kosei Hosp, Dept Cardiol, Anjo, Japan
[2] Nagoya Univ, Dept Cardiol, Grad Sch Med, Nagoya, Japan
[3] Nagoya Univ, Dept Adv Cardiovasc Therapeut, Grad Sch Med, Nagoya, Japan
来源
关键词
inappropriate shock therapies; oversensing episodes; QRS amplitude; subcutaneous implantable cardioverter-defibrillator; synthesized 18-lead electrocardiogram; EFFICACY; SAFETY; ORIGIN;
D O I
10.1111/pace.15086
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundPatients with subcutaneous implantable cardioverter-defibrillators (S-ICDs) experience an oversensing episode (OS) more frequently than those with transvenous ICDs. However, no established electrocardiography (ECG) parameters can accurately detect an OS. This study aimed to evaluate the incidence of an OS in real-world clinical practice and the association of synthesized 18-lead ECG (syn18-ECG) parameters with an OS. MethodsWe retrospectively included 21 consecutive patients who underwent S-ICD implantation and collected syn18-ECG parameters. We placed the generator in a deep posterior position and defined an OS as an inappropriate charging episode caused by cardiac or noncardiac signals. A SMART pass filter and two tachyarrhythmia zones were programed. ResultsThe most frequent underlying heart disease was Brugada/J wave syndrome (n = 7). During a median follow-up period of 1188 days, an OS was observed in six patients (28.6%). The QRS amplitude in synthesized V7 lead (synV7) was significantly lower in the OS group than in the non-OS group (0.59 +/- 0.17 vs. 0.91 +/- 0.35 mV, p = 0.019). The optimal cutoff value of synV7 QRS amplitude was 0.61 mV, with a sensitivity of 80.0% and a specificity of 83.7% for predicting an OS. Univariate logistic analysis showed that a synV7 QRS amplitude of <0.61 mV was only associated with an OS (odd ratio, 20.0; 95% confidence interval, 1.66-241.72; p = 0.018). ConclusionsIn patients with S-ICDs, an OS was not a rare complication during long-term follow-up. A low synV7 QRS amplitude was associated with a high OS incidence.
引用
收藏
页码:1565 / 1573
页数:9
相关论文
共 50 条
  • [31] Use of implantable cardioverter-defibrillators in pediatric patients
    Shannon, KM
    CURRENT OPINION IN CARDIOLOGY, 2002, 17 (03) : 280 - 282
  • [32] Sudden death in patients with implantable cardioverter-defibrillators
    Li, HG
    Axtell, K
    Biehl, M
    Deshpande, S
    Dhala, A
    Blanck, Z
    Sra, J
    Jazayeri, M
    Akhtar, M
    AMERICAN HEART JOURNAL, 1996, 132 (05) : 986 - 988
  • [33] Sport Participation in Patients with Implantable Cardioverter-Defibrillators
    Rachel Lampert
    Current Treatment Options in Cardiovascular Medicine, 2019, 21
  • [34] Underutilization of Implantable Cardioverter-Defibrillators in Older Patients
    Hauser, Robert G.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2015, 313 (24): : 2429 - 2430
  • [35] INAPPROPRIATE DISCHARGES IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    Gomes, R.
    Rocha, S.
    Silva, J.
    Almeida, S.
    Carmo, P.
    Santos, K. R.
    Cavaco, D.
    Morgado, F.
    Adragao, P.
    Silva, J. A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 : S87 - S87
  • [36] SURVIVAL IN PATIENTS DECLINING IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    PINSKI, SL
    SGARBOSSA, EB
    MALONEY, JD
    TROHMAN, RG
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (08): : 800 - 801
  • [37] Effect of Extracellular Matrix Envelopes on Shock Impedance in Patients With Subcutaneous Implantable Cardioverter-Defibrillators
    Sharma, Esseim
    Wang, Wei
    Tadros, Thomas M.
    Koplan, Bruce A.
    Zei, Paul C.
    Maytin, Melanie
    Romero, Jorge
    Tedrow, Usha
    Sauer, William
    Kapur, Sunil
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (05) : 701 - 703
  • [38] Is 40 Joules Enough to Successfully Defibrillate With Subcutaneous Implantable Cardioverter-Defibrillators?
    Biffi, Mauro
    Bongiorni, Maria Grazia
    D'Onofrio, Antonio
    Manzo, Michele
    Pieragnoli, Paolo
    Palmisano, Pietro
    Ottaviano, Luca
    Perego, Giovanni Battista
    Pangallo, Antonio
    Lavalle, Carlo
    Bonfantino, Vincenzo
    Nigro, Gerardo
    Landolina, Maurizio Eugenio
    Katsouras, Grigorios
    Diemberger, Igor
    Viani, Stefano
    Bianchi, Valter
    Lovecchio, Mariolina
    Valsecchi, Sergio
    Ziacchi, Matteo
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (06) : 767 - 776
  • [39] Importance of Flexibility in Shock Polarity With Subcutaneous Only Implantable Cardioverter-Defibrillators
    Smith, Warren M.
    Hood, Margaret
    Grace, Andrew
    Bardy, Gust
    CIRCULATION, 2010, 122 (21)
  • [40] Effectiveness of subcutaneous implantable cardioverter-defibrillators and determinants of inappropriate shock delivery
    Mesquita, Joao
    Cavaco, Diogo
    Ferreira, Antonio
    Lopes, Nicodemus
    Santos, Pedro G.
    Carvalho, Maria S.
    Haas, Andreia
    Costa, Francisco
    Carmo, Pedro
    Morgado, Francisco
    Adragao, Pedro
    Mendes, Miguel
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 232 : 176 - 180