Synthesized V7 QRS Amplitude and Oversensing Episodes in Patients With Subcutaneous Implantable Cardioverter-Defibrillators

被引:0
|
作者
Okajima, Takashi [1 ,2 ]
Ishikawa, Shinji [1 ]
Yanagisawa, Satoshi [2 ,3 ]
Okamoto, Takayuki [1 ]
Uemura, Yusuke [1 ]
Takemoto, Kenji [1 ]
Inden, Yasuya [2 ]
Murohara, Toyoaki [2 ]
Watarai, Masato [1 ]
机构
[1] Anjo Kosei Hosp, Dept Cardiol, Anjo, Japan
[2] Nagoya Univ, Dept Cardiol, Grad Sch Med, Nagoya, Japan
[3] Nagoya Univ, Dept Adv Cardiovasc Therapeut, Grad Sch Med, Nagoya, Japan
来源
关键词
inappropriate shock therapies; oversensing episodes; QRS amplitude; subcutaneous implantable cardioverter-defibrillator; synthesized 18-lead electrocardiogram; EFFICACY; SAFETY; ORIGIN;
D O I
10.1111/pace.15086
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundPatients with subcutaneous implantable cardioverter-defibrillators (S-ICDs) experience an oversensing episode (OS) more frequently than those with transvenous ICDs. However, no established electrocardiography (ECG) parameters can accurately detect an OS. This study aimed to evaluate the incidence of an OS in real-world clinical practice and the association of synthesized 18-lead ECG (syn18-ECG) parameters with an OS. MethodsWe retrospectively included 21 consecutive patients who underwent S-ICD implantation and collected syn18-ECG parameters. We placed the generator in a deep posterior position and defined an OS as an inappropriate charging episode caused by cardiac or noncardiac signals. A SMART pass filter and two tachyarrhythmia zones were programed. ResultsThe most frequent underlying heart disease was Brugada/J wave syndrome (n = 7). During a median follow-up period of 1188 days, an OS was observed in six patients (28.6%). The QRS amplitude in synthesized V7 lead (synV7) was significantly lower in the OS group than in the non-OS group (0.59 +/- 0.17 vs. 0.91 +/- 0.35 mV, p = 0.019). The optimal cutoff value of synV7 QRS amplitude was 0.61 mV, with a sensitivity of 80.0% and a specificity of 83.7% for predicting an OS. Univariate logistic analysis showed that a synV7 QRS amplitude of <0.61 mV was only associated with an OS (odd ratio, 20.0; 95% confidence interval, 1.66-241.72; p = 0.018). ConclusionsIn patients with S-ICDs, an OS was not a rare complication during long-term follow-up. A low synV7 QRS amplitude was associated with a high OS incidence.
引用
收藏
页码:1565 / 1573
页数:9
相关论文
共 50 条
  • [21] Premature battery depletion of EMBLEM subcutaneous implantable cardioverter-defibrillators
    Ip, James E.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (03) : 565 - 567
  • [22] Subcutaneous Implantable Cardioverter-Defibrillators and Sternal Wires A Cautionary Tale
    Winter, Joachim
    Kohlmeier, Antonia
    Shin, Dong-In
    O'Connor, Stephen
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (05): : 986 - 987
  • [23] Predictors of pace-terminable rhythms in patients with subcutaneous implantable cardioverter-defibrillators
    Rao, Birju R.
    Jain, Vardhmaan
    Mekary, Wissam
    Ibrahim, Rand
    Bhatia, Neal K.
    El Chami, Mikhael
    Knops, Reinoud E.
    Lloyd, Michael S.
    HEART RHYTHM, 2024, 21 (11) : 2346 - 2347
  • [24] Venous thromboembolism in patients with implantable cardioverter-defibrillators
    Pedersen, Susanne Bendesgaard
    Hjortshoj, Soren Pihlkjaer
    Botker, Hans Erik
    Farkas, Dora Kormendine
    Schmidt, Morten
    Sorensen, Henrik Toft
    Nielsen, Jens Cosedis
    EUROPACE, 2017, 19 (06): : 991 - 1001
  • [25] Sport Participation in Patients with Implantable Cardioverter-Defibrillators
    Lampert, Rachel
    CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE, 2019, 21 (11)
  • [26] MORE ON PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - RESPONSE
    PINSKI, SL
    TROHMAN, RG
    ANNALS OF INTERNAL MEDICINE, 1995, 123 (11) : 893 - 893
  • [27] Physical Function of Patients With Implantable Cardioverter-Defibrillators
    Kim, Jin Shil
    Pressler, Susan J.
    Welch, Janet L.
    Damush, Teresa
    Sloan, Rebecca S.
    Wu, Jingwei
    Groh, William J.
    JOURNAL OF CARDIOVASCULAR NURSING, 2009, 24 (05) : 398 - 409
  • [28] Pacemakers and implantable cardioverter-defibrillators in pediatric patients
    Silka, Michael J.
    Bar-Cohen, Yaniv
    HEART RHYTHM, 2006, 3 (11) : 1360 - 1366
  • [29] Prognostic Factors in Patients With Implantable Cardioverter-Defibrillators
    Kalay, Nihat
    Inanc, Tugrul
    Ergin, Ali
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (08) : 681 - 681
  • [30] Inaccuracy of automated electrogram amplitude measurements in implantable cardioverter-defibrillators
    Khoobiar, Sargis
    Curwin, Jay H.
    Coyne, Robert F.
    Raquet, Sherri
    Sussman, Jonathan S.
    Quinlan, Karen L.
    Winters, Stephen L.
    CIRCULATION, 2007, 115 (21) : E557 - E557