Synthesized V7 QRS Amplitude and Oversensing Episodes in Patients With Subcutaneous Implantable Cardioverter-Defibrillators

被引:0
|
作者
Okajima, Takashi [1 ,2 ]
Ishikawa, Shinji [1 ]
Yanagisawa, Satoshi [2 ,3 ]
Okamoto, Takayuki [1 ]
Uemura, Yusuke [1 ]
Takemoto, Kenji [1 ]
Inden, Yasuya [2 ]
Murohara, Toyoaki [2 ]
Watarai, Masato [1 ]
机构
[1] Anjo Kosei Hosp, Dept Cardiol, Anjo, Japan
[2] Nagoya Univ, Dept Cardiol, Grad Sch Med, Nagoya, Japan
[3] Nagoya Univ, Dept Adv Cardiovasc Therapeut, Grad Sch Med, Nagoya, Japan
来源
关键词
inappropriate shock therapies; oversensing episodes; QRS amplitude; subcutaneous implantable cardioverter-defibrillator; synthesized 18-lead electrocardiogram; EFFICACY; SAFETY; ORIGIN;
D O I
10.1111/pace.15086
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundPatients with subcutaneous implantable cardioverter-defibrillators (S-ICDs) experience an oversensing episode (OS) more frequently than those with transvenous ICDs. However, no established electrocardiography (ECG) parameters can accurately detect an OS. This study aimed to evaluate the incidence of an OS in real-world clinical practice and the association of synthesized 18-lead ECG (syn18-ECG) parameters with an OS. MethodsWe retrospectively included 21 consecutive patients who underwent S-ICD implantation and collected syn18-ECG parameters. We placed the generator in a deep posterior position and defined an OS as an inappropriate charging episode caused by cardiac or noncardiac signals. A SMART pass filter and two tachyarrhythmia zones were programed. ResultsThe most frequent underlying heart disease was Brugada/J wave syndrome (n = 7). During a median follow-up period of 1188 days, an OS was observed in six patients (28.6%). The QRS amplitude in synthesized V7 lead (synV7) was significantly lower in the OS group than in the non-OS group (0.59 +/- 0.17 vs. 0.91 +/- 0.35 mV, p = 0.019). The optimal cutoff value of synV7 QRS amplitude was 0.61 mV, with a sensitivity of 80.0% and a specificity of 83.7% for predicting an OS. Univariate logistic analysis showed that a synV7 QRS amplitude of <0.61 mV was only associated with an OS (odd ratio, 20.0; 95% confidence interval, 1.66-241.72; p = 0.018). ConclusionsIn patients with S-ICDs, an OS was not a rare complication during long-term follow-up. A low synV7 QRS amplitude was associated with a high OS incidence.
引用
收藏
页码:1565 / 1573
页数:9
相关论文
共 50 条
  • [1] Clinical impact of ECG changes on oversensing of subcutaneous implantable cardioverter-defibrillators
    Hakamata, Takahiro
    Otsuki, Sou
    Izumi, Daisuke
    Sakaguchi, Yuta
    Suzuki, Naomasa
    Ikami, Yasuhiro
    Hasegawa, Yuki
    Yagihara, Nobue
    Iijima, Kenichi
    Chinushi, Masaomi
    Fuse, Koichi
    Inomata, Takayuki
    HEART RHYTHM, 2022, 19 (10) : 1704 - 1711
  • [2] Fragmented QRS and arrhythmic events in patients with implantable cardioverter-defibrillators
    Kucharz, Anna
    Kulakowski, Piotr
    KARDIOLOGIA POLSKA, 2020, 78 (11) : 1107 - 1114
  • [3] T-Wave Oversensing with Contemporary Implantable Cardioverter-Defibrillators
    Strik, Marc
    Ploux, Sylvain
    Eschalier, Romain
    Mondoly, Pierre
    Fontagne, Leslie
    Ramirez, F. Daniel
    Haissaguerre, Michel
    Bordachar, Pierre
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (10)
  • [4] Clinical experience with subcutaneous implantable cardioverter-defibrillators
    Geoffrey F. Lewis
    Michael R. Gold
    Nature Reviews Cardiology, 2015, 12 : 398 - 405
  • [5] Clinical experience with subcutaneous implantable cardioverter-defibrillators
    Lewis, Geoffrey F.
    Gold, Michael R.
    NATURE REVIEWS CARDIOLOGY, 2015, 12 (07) : 398 - 405
  • [6] A SUBCUTANEOUS LEAD ARRAY FOR IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    JORDAENS, L
    VERTONGEN, P
    VANBELLEGHEM, Y
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (07): : 1429 - 1433
  • [7] Subcutaneous Implantable Cardioverter-Defibrillators in Patients With Congenital Heart Disease
    Waldmann, Victor
    Marquie, Christelle
    Bessiere, Francis
    Perrot, David
    Anselme, Frederic
    Badenco, Nicolas
    Barra, Sergio
    Bertaux, Geraldine
    Blangy, Hugues
    Bordachar, Pierre
    Boveda, Serge
    Chauvin, Michel
    Clementy, Nicolas
    Clerici, Gael
    Combes, Nicolas
    Defaye, Pascal
    Deharo, Jean-Claude
    Durand, Philippe
    Duthoit, Guillaume
    Eschalier, Romain
    Fauchier, Laurent
    Garcia, Rodrigue
    Geoffroy, Olivier
    Gitenay, Edouard
    Gourraud, Jean-Baptiste
    Guenancia, Charles
    Iserin, Laurence
    Jacon, Peggy
    Jesel-Morel, Laurence
    Kerkouri, Fawzi
    Klug, Didier
    Koutbi, Linda
    Labombarda, Fabien
    Ladouceur, Magalie
    Laurent, Gabriel
    Leclercq, Christophe
    Maille, Baptiste
    Maltret, Alice
    Massoulie, Gregoire
    Mondoly, Pierre
    Ninni, Sandro
    Ollitrault, Pierre
    Pasquie, Jean-Luc
    Pierre, Bertrand
    Pujadas, Penelope
    Champ-Rigot, Laure
    Sacher, Frederic
    Sadoul, Nicolas
    Schatz, Alexandre
    Winum, Pierre
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (07) : 590 - 599
  • [8] Incidence of oversensing resulting in inappropriate shocks in transvenous implantable cardioverter-defibrillators
    Cho, YK
    Corsello, A
    Robotis, D
    Okreglicki, A
    Rosero, SZ
    Daubert, JP
    Huang, DT
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 89A - 89A
  • [9] Subcutaneous Implantable Cardioverter-Defibrillators: Expanding the Scope of Technology
    Saeed, Mohammad
    TEXAS HEART INSTITUTE JOURNAL, 2014, 42 (02): : 139 - 139
  • [10] Longitudinal Outcomes of Subcutaneous or Transvenous Implantable Cardioverter-Defibrillators in Older Patients
    Friedman, Daniel J.
    Qin, Li
    Parzynski, Craig
    Heist, E. Kevin
    Russo, Andrea M.
    Ranasinghe, Isuru
    Zeitler, Emily P.
    Minges, Karl E.
    Akar, Joseph G.
    Freeman, James V.
    Curtis, Jeptha P.
    Al-Khatib, Sana M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (11) : 1050 - 1059