Analysis of the Influence of Process Parameters on Transverse Flux Induction Heating of Endless-Rolling Strip

被引:0
|
作者
Gao, Lin [1 ,2 ]
Shi, Fang-Zhou [1 ]
Yan, Meng [1 ]
He, Yi-Ping [2 ]
Xiang, Jian [2 ]
Qi, Xiao-Hu [2 ]
Huang, Hua-Gui [1 ]
机构
[1] Yanshan Univ, Natl Engn Res Ctr Equipment & Technol Cold Rolled, Qinhuangdao 066004, Peoples R China
[2] Erzhong Deyang Heavy Equipment Co Ltd, Deyang 618000, Peoples R China
关键词
endless rolling; transverse flux induction heating; temperature uniformity; multi-physics coupling; finite element simulation; EDDY-CURRENT; EQUIPMENT;
D O I
10.3390/met15020218
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study focuses on the effect of an induction heating device on the entry of a thin strip continuous casting and rolling line. A finite element model for the electromagnetic-thermal coupling of transverse magnetic flux induction heating was developed by adopting COMSOL software 6.1 to systematically investigate the effects of process parameters on the magnetic field, eddy current field, and the transverse temperature distribution of the strip. The results show that when the gap is between 20 mm and 40 mm, the maximum value of magnetic induction in the overheating region at the edges of the strip increases from 0.28 T to 0.35 T and 0.38. When the strip width is 1000 mm, there is an approximately 29% increase in magnetic induction in comparison to a strip with a width of 800 mm, and both eddy current density and temperature exhibit abnormal fluctuations. The maximum temperature difference in the temperature uniformity region at the center of the strip is only 3 degrees C at different frequencies, and the temperature-rise curves almost completely overlap. With increasing current, the temperature difference between the weak temperature region and the temperature uniformity region at the center widens, indicating a deterioration in temperature uniformity. Meanwhile, the field conditions are simulated using a simplified model of continuous heating. The results indicate that the maximum temperature deviation in the overheating region at the edges of the strip is 6 degrees C, while the deviation in the temperature uniformity region is 2 degrees C. Furthermore, the simulation data reveal an average temperature rise of 1156 degrees C across the width of the strip, with a deviation of 1.4 degrees C compared to the measured results, which verifies the validity of the proposed model. The analysis results provide a reference basis for designing transverse magnetic flux induction heating devices and optimizing process parameters.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Numerical and experimental analysis of an electro-thermal coupled problem for transverse flux induction heating equipment
    Dughiero, F
    Forzan, M
    Lupi, S
    Tasca, M
    IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) : 3106 - 3109
  • [42] Study on the influence of vibration parameters in the twin-roll strip vibration cast-rolling process
    Minghan Sun
    Zhiwang Zhu
    Likang Zheng
    Shipeng Guo
    Fengshan Du
    The International Journal of Advanced Manufacturing Technology, 2020, 108 : 3141 - 3157
  • [43] Investigations into the influence of asymmetric factors and rolling parameters on strip curvature during hot rolling
    Knight, CW
    Hardy, SJ
    Lees, AW
    Brown, KJ
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2003, 134 (02) : 180 - 189
  • [44] Research method and measure analysis of transverse temperature in hot rolling strip
    Mechanical Engineering School, University of Science and Technology Beijing, Beijing 100083, China
    不详
    Beijing Keji Daxue Xuebao, 2007, SUPPL. 2 (140-143):
  • [45] Research on the influence of process parameters of traveling induction heating method for welding deformation straightening
    Feng, Y. L.
    Liu, Y. J.
    Li, R.
    Wang, J.
    TRENDS IN MARITIME TECHNOLOGY AND ENGINEERING, MARTECH 2022, VOL 1, 2022, 8 : 91 - 97
  • [46] Influence of Parameters during Induction Heating Cycle of 7075 Aluminium Alloys with RAP Process
    Vaneetveld, G.
    Rassili, A.
    Atkinson, H. V.
    SEMI-SOLID PROCESSING OF ALLOYS AND COMPOSITES X, 2008, 141-143 : 719 - +
  • [47] Analysis on the Influence of Cross Wedge Rolling Process Parameters on the Process of the Hollow Shaft Parts
    Yuan, Wen-Sheng
    Huang, Ru-Gang
    Wang, Zhong-Lei
    Li, Jin
    2015 International Conference on Mechanical Engineering and Automation (ICMEA 2015), 2015, : 157 - 163
  • [48] Rolling of AZ31 magnesium alloy strip using induction heating rolls
    Cai, Ban
    Li, Changsheng
    Zhang, Jian
    Song, Yanlei
    Zheng, Jianjun
    11TH INTERNATIONAL CONFERENCE ON TECHNOLOGY OF PLASTICITY, ICTP 2014, 2014, 81 : 209 - 214
  • [49] Transverse flux induction heating: comparison between numerical models and experimental validation
    Fireteanu, V
    Geri, A
    Tudorache, T
    Veca, GM
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2003, 22 (01) : 98 - 110
  • [50] Intelligent Optimization of Process Parameters in Limit Gauge Hot Strip Rolling
    Jing, Fengwei
    Li, Junliang
    Hao, Shimeng
    Li, Jie
    Wang, Jing
    APPLIED SCIENCES-BASEL, 2022, 12 (16):