Local diagnostic reference levels for cardiac computed tomography

被引:0
|
作者
Pilat, Wiktoria [1 ]
Kidon-Szoltysek, Joanna [1 ,2 ]
Stasiow, Bartlomiej [3 ]
机构
[1] Upper Silesian Med Ctr, Dept Med Phys, Katowice, Poland
[2] Med Univ Silesia, Invas Cardiol & Electrocardiol Dept, Dept Cardiol 3, Katowice, Poland
[3] Upper Silesian Med Ctr, Diagnost Imaging Dept, Katowice, Poland
来源
关键词
Cardiac Computed Tomography (CCT); dual-source computed tomography; Diagnostic Reference Levels (DRLs); CT;
D O I
10.2478/pjmpe-2024-0035
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Clinical applications of cardiac computed tomography in our center include the diagnosis of coronary arteries, assessment of their narrowing, evaluation of cardiac function, and assessment of the heart's structure. The aim of this study was the determination of local DRLs for cardiac CT sequence (designed to evaluate coronary arteries, function, and structure of the heart in one sequence) and calcium score sequence.Material and Methods: The research group consisted of 2234 patients undergoing cardiac computed tomography, including calcium score, cardiac CT angiography, evaluation of cardiac function and cardiac structure. The studies were conducted using a dual-source Somatom Force computed tomography scanner (2019, Siemens). An assessment of the dose received by the patient was performed based on the analysis of the volumetric tomographic dose index (CTDIvol) and the dose-length product (DLP), taking into account body mass index (BMI).Results: The DRL value for all patients undergoing cardiac computed tomography (one sequence including evaluation of calcium score, cardiac angiography, cardiac function, and cardiac structure) and calcium score sequence (in brackets) were 901.5 (92.3) mGy<middle dot>cm. When broken down by BMI category, the values were 869.9 (87.7) mGy<middle dot>cm, 880.9 (89.6) mGy<middle dot>cm, 889.3 (91.4) mGy<middle dot>cm, 941.0 (95.8) mGy<middle dot>cm, for underweight, normal BMI, overweight and obese patients, respectively.Conclusion: Diagnostic reference levels should be carefully determined, taking into account BMI, detailed information about the CT protocol, and type of CT scanner. Careful determination and regular updates of diagnostic reference levels are essential for optimizing the radiological protection of the patient.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A Contribution to the Establishment of Diagnostic Reference Levels in Computed Tomography in Brazil
    Narciso, L. D. L.
    Lima, N. W.
    Dartora, C. M.
    Marques da Silva, A. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 737 - 740
  • [22] Paediatric diagnostic reference levels in computed tomography: a systematic review
    Satharasinghe, D. M.
    Jeyasugiththan, J.
    Wanninayake, W. M. N. M. B.
    Pallewatte, A. S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (01) : R1 - R27
  • [23] Estimation of radiation dose and establishment of local diagnostic reference levels for computed tomography of head in pediatric population
    Priyanka
    Kadavigere, Rajagopal
    Sukumar, Suresh
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (05) : 983 - 991
  • [24] A survey of local diagnostic reference levels for the head, thorax, abdomen and pelvis computed tomography in Norway and Canada
    Tonkopi, Elena
    Wikan, Eline Jahre
    Hovland, Tor Olav
    Hogset, Sivert
    Kofod, Thomas Alexander
    Sefenu, Selasi K.
    Hughes-Ryan, Emily
    d'Entremont-O'Connell, Dakota
    Gunn, Catherine
    Holter, Tanja
    Johansen, Safora
    ACTA RADIOLOGICA OPEN, 2022, 11 (10)
  • [25] Local Diagnostic Reference Levels and Size-Specific Patient Dose in Computed Tomography at a Greek Hospital
    Stasinou, D.
    Zoiopoulou, V.
    Antonakos, J.
    Argentos, S.
    Efstathopoulos, E.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [26] The establishment of local diagnostic reference levels for computed tomography cerebral angiography in Jeddah city of Saudi Arabia
    Khan, Khadijah
    Al-Harbi, Afnan
    Fallatah, Alaa
    Alasmary, Mohamed
    Bokhary, Younis
    Alhazmi, Marwan
    Al-Qahtani, Saeed
    Ajlouni, Abdulwali
    Alotaibi, Emtenan
    Alomari, Ali
    Althomali, Marwan
    Algethami, Merfat
    Bawazeer, Omemh
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2025, 56 (01):
  • [27] Establishment of Local Diagnostic Reference Levels of Routine Abdomen Exam in Computed Tomography According to Body Weight
    Wang, H.
    Wang, Y.
    Weng, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3228 - 3228
  • [28] Paediatric computed tomography diagnostic reference levels in Africa: A systematic review
    Gyan, Emmanuel
    Subaar, Christiana
    Edusei, George
    Antwi Nyarko, Linda
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2025, 72 (01) : 139 - 147
  • [29] Establishing national paediatric computed tomography diagnostic reference levels in Ghana
    Shirazu, Issahaku
    Sackey, Theophilus A.
    Edziah, Raymond
    Boateng, Yaw Mensah
    Schandorf, Cyril.
    HEALTH AND TECHNOLOGY, 2024, 14 (06) : 1187 - 1198
  • [30] Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt
    Salama, Dina Husseiny
    Vassileva, Jenia
    Mahdaly, Gamal
    Shawki, Mona
    Salama, Ahmad
    Gilley, Debbie
    Rehani, Madan Mohan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 : 16 - 24