In Vitro Modelling of Aortic Dissection for Bare-Metal Stent Intervention

被引:0
|
作者
Kobayashi, Mayo [1 ]
Shiraishi, Yasuyuki [2 ]
Chikweto, Francis [2 ]
Fukai, Miharu [1 ]
Hou, Xiaoxi [1 ]
Fukaya, Aoi [2 ,3 ]
Ikura, Maiko [4 ]
Hanzawa, Kazuhiko [4 ]
Yambe, Tomoyuki [2 ]
机构
[1] Tohoku Univ, Grad Sch Med Engn, Sendai, Miyagi, Japan
[2] Tohoku Univ, Dept Med Engn & Cardiol, Inst Dev Aging & Canc, Preclin Res Ctr, Sendai, Miyagi, Japan
[3] Tohoku Bunka Gakuen Univ, Fac Engn, Dept Clin Engn, Sendai, Miyagi, Japan
[4] Niigata Univ, Grad Sch Med, Adv Treatment & Prevent Vasc Dis & Embolism, Niigata, Japan
关键词
Aortic Dissection; Bare-metal Stent; In Vitro Examination;
D O I
10.1007/978-3-031-80355-0_2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Type-A aortic dissection (AD) is associated with a high mortality rate of over 93% in 24 h after vascular events. In the elderly, there is often a limitation for surgical treatment. Therefore, there is an increasing need for minimally invasive treatment methods. The study aims to develop an in vitro circulatory model reproducing the haemodynamics of AD to investigate the therapeutic effect of a newly designed bare-metal-stent on the amelioration of the lesion. In this study, we conducted in vivo experiment in order to measure basic data on the anatomical morphology and haemodynamics of AD. Based on these results, we have developed a new in vitro elastic dissection model that provides indexes of design features for stent development. This model was made of silicone, which could be visualised by echocardiography imaging, and had a layered structure similar to that of a natural aorta. The in vivo experiments confirmed that the stenting had compressed the false lumen and reduced blood flow. The in vitro model visualized the haemodynamics of aortic dissection under pulsatile flow conditions and showed that the false lumen (FL) pressure was higher than the true lumen (TL) pressure. Consequently, we were able to visualize the haemodynamics of aortic dissection and develop a model that can evaluate the pressure exerted by the stent on the FL under pulsatile flow conditions. In the future, we will be able to observe more detailed haemodynamics when stents are implanted in this model representing several types of Type A AD clinical cases.
引用
收藏
页码:10 / 18
页数:9
相关论文
共 50 条
  • [1] Treatment with transfemoral bare-metal stent of residual aortic arch dissection after surgical repair of acute type an aortic dissection
    Di Toinmaso, Luigi
    Giordano, Raffaele
    Di Tominaso, Ettorino
    Di Palo, Giusi
    Iannelli, Gabriele
    JOURNAL OF THORACIC DISEASE, 2018, 10 (11) : 6097 - 6106
  • [2] Symptomatic Aortic Bare-Metal Stent Fracture after PETTICOAT Technique for Complicated Type B Aortic Dissection
    Santos, Africa Duque
    Valdivia, Andres Reyes
    Alguacil, Sergio Gordillo
    Guaita, Julia Ocana
    Zuniga, Claudio Gandarias
    ANNALS OF VASCULAR SURGERY, 2019, 59 : 311.e1 - 311.e4
  • [3] The Myths of the Bare-Metal Stent
    Kereiakes, Dean J.
    JAMA CARDIOLOGY, 2018, 3 (11) : 1039 - 1040
  • [4] Endovascular treatment of acute type A aortic dissection in a nonagenarian: stabilization of a short covered stent using a bare-metal stent
    Wamala, Isaac
    Heck, Roland
    Falk, Volkmar
    Buz, Semih
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 29 (06) : 978 - 980
  • [5] Hemodynamic study of overlapping bare-metal stents intervention to aortic aneurysm
    Zhang, Peng
    Sun, Anqiang
    Zhan, Fan
    Luan, Jingyuan
    Deng, Xiaoyan
    JOURNAL OF BIOMECHANICS, 2014, 47 (14) : 3524 - 3530
  • [6] In vivo construction of a multilayer bare-metal stent for the treatment of an aortic mycotic pseudoaneurysm
    Kahn, S. Lowell
    Peeran, Syed
    Smolinski, Sara
    Norris, Marc
    Rhee, Sang W.
    Kaufman, Jeffrey
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (03) : 744 - 746
  • [7] Combined Proximal Endografting With Distal Bare-Metal Stenting for Management of Aortic Dissection
    Hofferberth, Sophie C.
    Foley, Peter T.
    Newcomb, Andrew E.
    Yap, Kelvin K.
    Yii, Michael Y.
    Nixon, Ian K.
    Wilson, Andrew M.
    Mossop, Peter J.
    ANNALS OF THORACIC SURGERY, 2012, 93 (01): : 95 - 102
  • [8] Drug-Eluting Versus Bare-Metal Stents for Bare-Metal In-Stent Restenosis
    Singh, Inder M.
    Filbly, Steven J.
    El Sakr, Fredy
    Gorodeski, Eiran Z.
    Lincoff, A. Michael
    Ellis, Stephen G.
    Shishehbor, Mehdi H.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 145D - 145D
  • [9] VERY LATE BARE-METAL STENT THROMBOSIS
    Shamsi, Fahad
    Tai, Javed
    Arshad, Sadia
    PAKISTAN HEART JOURNAL, 2015, 48 (02): : 114 - 117
  • [10] Early results of bare metal extension stent for thoracoabdominal aortic dissection
    Vargo, Patrick R.
    Tarola, Christopher L.
    Durbak, Emily
    Doh, Chang Yoon
    Caputo, Francis J.
    Smolock, Christopher J.
    Roselli, Eric E.
    JTCVS TECHNIQUES, 2022, 14 : 1 - 8