Treatment with transfemoral bare-metal stent of residual aortic arch dissection after surgical repair of acute type an aortic dissection

被引:6
|
作者
Di Toinmaso, Luigi [1 ]
Giordano, Raffaele [1 ]
Di Tominaso, Ettorino [1 ]
Di Palo, Giusi [1 ]
Iannelli, Gabriele [1 ]
机构
[1] Univ Naples Federico II, Dept Adv Biomed Sci, Adult & Pediat Cardiac Surg, Naples, Italy
关键词
Type A aortic dissection (TAAD); endovascular treatment; uncovered stents; DISTAL AORTA; FALSE LUMEN; SURGERY; REOPERATION; REPLACEMENT; PREDICTORS; MANAGEMENT; MORTALITY; REGISTRY; PATENCY;
D O I
10.21037/jtd.2018.10.51
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Here we evaluate the usefulness of transfemoral uncovered stent implantation to avoid secondary conventional surgery for residual type A aortic dissection (TAAD) of the aortic arch after ascending aorta replacement. Methods: From June 2009 to April 2015, 11 patients were treated with transfemoral implantation of uncovered stents in the aortic arch after surgical replacement of ascending aorta performed on average 4.7 +/- 2.3 years earlier. An enlarged dissected aortic arch or a dangerous median growth of more than 5 mm/yr or impending rupture presenting as chest pain were indications for treatment. The dissected aortic tracts diameter must not exceed 45 mm. Five patients (45.5%) were treated with Djumbodies Dissection System, 6 patients (54.5%) with Jotec E-XL aortic stent. Results: There were no perioperative deaths or permanent neurologic complications. Primary procedural success was obtained in all patients and the residual TAAD in aortic arch was obliterated, with disappearance of the false lumen. Median intensive care unit (ICU) stay was 24 hours; post-operative hospital stay was 5.2 +/- 1.4 days. One death, not aortic related, occurred during follow-up period (mean 5.2 +/- 1.9 years). Descending thoracic aorta diameter significantly increased in 3 patients (27.3%): one patient (9.0%) needed a secondary conventional surgery, the other 2 (18.2%) of a distal extension with PETTICOAT approach. Conclusions: Endovascular approach with uncovered metal bare stent is surely an evolving strategy to perform a purely endovascular treatment, indicated only for treatment of an aortic arch with a diameter of less than 40 or 45 mm, to avoid progressive thoracic aortic dilatation and/or rupture.
引用
收藏
页码:6097 / 6106
页数:10
相关论文
共 50 条
  • [1] Hybrid Aortic Repair of Dissecting Aortic Arch Aneurysm after Surgical Treatment of Acute Type A Dissection
    Canaud, Ludovic
    Gandet, Thomas
    Ozdemir, Bans Ata
    Albat, Bernard
    Marty-Ane, Charles
    Alric, Pierre
    ANNALS OF VASCULAR SURGERY, 2016, 30 : 175 - 180
  • [2] Endovascular treatment of acute type A aortic dissection in a nonagenarian: stabilization of a short covered stent using a bare-metal stent
    Wamala, Isaac
    Heck, Roland
    Falk, Volkmar
    Buz, Semih
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 29 (06) : 978 - 980
  • [3] Symptomatic Aortic Bare-Metal Stent Fracture after PETTICOAT Technique for Complicated Type B Aortic Dissection
    Santos, Africa Duque
    Valdivia, Andres Reyes
    Alguacil, Sergio Gordillo
    Guaita, Julia Ocana
    Zuniga, Claudio Gandarias
    ANNALS OF VASCULAR SURGERY, 2019, 59 : 311.e1 - 311.e4
  • [4] In Vitro Modelling of Aortic Dissection for Bare-Metal Stent Intervention
    Kobayashi, Mayo
    Shiraishi, Yasuyuki
    Chikweto, Francis
    Fukai, Miharu
    Hou, Xiaoxi
    Fukaya, Aoi
    Ikura, Maiko
    Hanzawa, Kazuhiko
    Yambe, Tomoyuki
    6TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, ICOBE 2023, 2025, 115 : 10 - 18
  • [5] Enlargement of aortic arch vessels after surgical repair of type A aortic dissection
    Yamauchi, Takashi
    Kubota, Suguru
    Ohata, Toshihiro
    Hasegawa, Kosei
    Ueda, Hideki
    JOURNAL OF VASCULAR SURGERY, 2017, 65 (03) : 669 - 675
  • [6] Repair of late aortic arch pseudoaneurysm following implantation of a novel bare metal aortic dissection stent
    Fakim, Djalal
    Besa, Santiago
    Ahmed, Mobeen
    Dubois, Luc
    Chu, Michael W. A.
    JTCVS TECHNIQUES, 2024, 24 : 20 - 22
  • [7] Aortic Remodeling After Hybrid Aortic Arch Repair of Chronic Residual Type A Aortic Dissection
    Shih, Chun Che
    Huang, Chun Yang
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E50 - E50
  • [8] Extended thoracic endovascular aortic repair for residual aortic dissection after type A aortic dissection repair
    Iida, Yasunori
    Hachiya, Takashi
    Asano, Ryota
    Inoue, Shinya
    Fujii, Susumu
    Sawa, Shigeharu
    Shimizu, Hideyuki
    VASCULAR, 2021, 29 (06) : 826 - 831
  • [9] Coagulopathy associated with residual dissection after surgical treatment of type A aortic dissection
    Nakajima, T
    Kin, H
    Minagawa, Y
    Komoda, K
    Izumoto, H
    Kawazoe, K
    JOURNAL OF VASCULAR SURGERY, 1997, 26 (04) : 609 - 615
  • [10] Uncovered stent-graft in the treatment for residual patent false lumen after surgical repair for acute type A aortic dissection
    Mastroroberto, Pasquale
    Chello, Massimo
    Jannelli, Gabriele
    Covino, Elvio
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 12 (02) : 202 - 204