Accuracy of a Novel High-Throughput "Car Blood Pressure" Measurement Protocol

被引:1
|
作者
Lima, Neiberg de Alcantara [1 ,2 ]
Cardozo, Shaun [1 ]
Johnson, Andrew [3 ]
Reed, Brian [3 ]
Korzeniewski, Steven [3 ,4 ]
Levy, Phillip D. [3 ,4 ]
Brook, Robert D. [1 ]
机构
[1] Wayne State Univ, Dept Internal Med, Div Cardiovasc Dis, Detroit, MI 48202 USA
[2] Hartford Hosp, Hartford HealthCare Heart & Vasc Inst, Hartford, CT 06106 USA
[3] Wayne State Univ, Integrated Biosci Ctr, Detroit, MI USA
[4] Wayne State Univ, Dept Emergency Med, Detroit, MI USA
关键词
blood pressure measurement; hypertension; public health; screening;
D O I
10.1093/ajh/hpaf016
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background More than one in three adults with hypertension in the United States are unaware of their condition, highlighting the importance of large-scale screening campaigns. Currently, the identification of hypertension is largely limited to medical settings. To help overcome this barrier, we developed a novel high-throughput screening protocol that measures blood pressure (BP) while patients remain seated in an automobile ("car-BP"). The aim of this study was to provide an initial assessment of the accuracy of car-BP.Methods Three BP readings were determined in a clinic exam room before and after three BP readings were taken while patients were seated in a parked car outside (n = 100 participants). The same validated device model (Omron HEM-907XL) and BP measurement methods adhering to guidelines were used in both scenarios. The average of all 6 clinic readings was compared to the average of the 3 car-BP readings in each individual.Results Mean clinic and car-BP readings were 120.9 +/- 16.2/78.0 +/- 9.9 and 118.9 +/- 15.2/76.0 +/- 10.0 mm Hg, respectively. The paired mean and absolute mean differences in systolic BP levels between methods were -1.92 mm Hg (95% confidence interval (CI) -3.2 to -0.7 mm Hg) and 4.8 mm Hg (95%CI 3.8 to 5.6 mm Hg), respectively. A total of 85% of participants had both systolic and diastolic BP levels <= 10 mm Hg different between measurement scenarios (meeting the a priori determined study primary outcome).Conclusions Car-BP represents an innovative and accessible approach for potential large-scale hypertension screening campaigns.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Novel miniaturized systems in high-throughput screening
    Battersby, BJ
    Trau, M
    TRENDS IN BIOTECHNOLOGY, 2002, 20 (04) : 167 - 173
  • [32] Novel chip designs for high-throughput electrophysiology
    Xu, JQ
    Wu, L
    Wang, XB
    Guia, A
    Yang, D
    Huang, MX
    Cui, CL
    Xu, M
    BIOPHYSICAL JOURNAL, 2002, 82 (01) : 161A - 161A
  • [33] High-throughput discovery of novel developmental phenotypes
    Mary E. Dickinson
    Ann M. Flenniken
    Xiao Ji
    Lydia Teboul
    Michael D. Wong
    Jacqueline K. White
    Terrence F. Meehan
    Wolfgang J. Weninger
    Henrik Westerberg
    Hibret Adissu
    Candice N. Baker
    Lynette Bower
    James M. Brown
    L. Brianna Caddle
    Francesco Chiani
    Dave Clary
    James Cleak
    Mark J. Daly
    James M. Denegre
    Brendan Doe
    Mary E. Dolan
    Sarah M. Edie
    Helmut Fuchs
    Valerie Gailus-Durner
    Antonella Galli
    Alessia Gambadoro
    Juan Gallegos
    Shiying Guo
    Neil R. Horner
    Chih-Wei Hsu
    Sara J. Johnson
    Sowmya Kalaga
    Lance C. Keith
    Louise Lanoue
    Thomas N. Lawson
    Monkol Lek
    Manuel Mark
    Susan Marschall
    Jeremy Mason
    Melissa L. McElwee
    Susan Newbigging
    Lauryl M. J. Nutter
    Kevin A. Peterson
    Ramiro Ramirez-Solis
    Douglas J. Rowland
    Edward Ryder
    Kaitlin E. Samocha
    John R. Seavitt
    Mohammed Selloum
    Zsombor Szoke-Kovacs
    Nature, 2016, 537 : 508 - 514
  • [34] High-throughput catalyst screening under high pressure conditions
    Rampf, FA
    Herrmann, WA
    CHEMIE INGENIEUR TECHNIK, 2001, 73 (1-2) : 97 - 99
  • [35] High-Throughput Optimization of a High-Pressure Catalytic Reaction
    Tanabe, Yusuke
    Sugisawa, Hiroki
    Miyazawa, Tomohisa
    Hotta, Kazuhiro
    Shiratori, Kazuya
    Fujitani, Tadahiro
    JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2025, 65 (05) : 2245 - 2250
  • [36] Improvement in accuracy and specificity of high-throughput sialic acid assay
    Markely, Lam Raga A.
    Jonnalagadda, Kanvasri N.
    Sinacore, Martin
    Ryll, Thomas
    Prajapati, Shashi
    ANALYTICAL METHODS, 2012, 4 (11) : 3565 - 3569
  • [37] High-Throughput Density Measurement Using Magnetic Levitation
    Ge, Shencheng
    Wang, Yunzhe
    Deshler, Nicolas J.
    Preston, Daniel J.
    Whitesides, George M.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2018, 140 (24) : 7510 - 7518
  • [38] A high-throughput assay for quantitative measurement of PCR errors
    Shagin, Dmitriy A.
    Shagina, Irina A.
    Zaretsky, Andrew R.
    Barsova, Ekaterina V.
    Kelmanson, Ilya V.
    Lukyanov, Sergey
    Chudakov, Dmitriy M.
    Shugay, Mikhail
    SCIENTIFIC REPORTS, 2017, 7
  • [39] High-Throughput Measurement of GPCR Stability At Femtomole Scale
    Knepp, Adam M.
    Grunbeck, Amy
    Banerjee, Sourabh
    Sakmar, Thomas P.
    Huber, Thomas
    BIOPHYSICAL JOURNAL, 2011, 100 (03) : 178 - 178
  • [40] A high-throughput assay for quantitative measurement of PCR errors
    Dmitriy A. Shagin
    Irina A. Shagina
    Andrew R. Zaretsky
    Ekaterina V. Barsova
    Ilya V. Kelmanson
    Sergey Lukyanov
    Dmitriy M. Chudakov
    Mikhail Shugay
    Scientific Reports, 7