Personalizing the Use of a Intermittently Scanned Continuous Glucose Monitoring Device in Individuals With Type 1 Diabetes: A Cost-Effectiveness Perspective in the Netherlands (FLARE-NL 9)

被引:5
|
作者
Emamipour, Sajad [1 ]
van Dijk, Peter R. [2 ]
Bilo, Henk J. G. [3 ,4 ]
Edens, Mireille A. [5 ]
van der Galien, Onno [6 ]
Postma, Maarten J. [7 ,8 ]
Feenstra, Talitha L. [9 ,10 ]
van Boven, Job F. M. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Clin Pharm & Pharmacol, Hanzepl 1, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Endocrinol, Groningen, Netherlands
[3] Isala, Diabet Ctr, Zwolle, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Internal Med, Groningen, Netherlands
[5] Isala, Dept Innovat & Sci, Zwolle, Netherlands
[6] Achmea, Zeist, Netherlands
[7] Univ Groningen, Univ Med Ctr Groningen, Dept Hlth Sci, Groningen, Netherlands
[8] Univ Groningen, Fac Econ & Business, Dept Econ Econometr & Finance, Groningen, Netherlands
[9] Univ Groningen, Groningen Res Inst Pharm, Fac Sci & Engn, Groningen, Netherlands
[10] Natl Inst Publ Hlth & Environm RIVM, Bilthoven, Netherlands
来源
关键词
cost-effectiveness analysis; hypoglycemia; intermittently scanned continuous glucose monitoring; type 1 diabetes mellitus;
D O I
10.1177/19322968221109841
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Intermittently scanned continuous glucose monitoring (isCGM) is a method to monitor glucose concentrations without using a finger prick. Among persons with type 1 diabetes (T1D), isCGM results in improved glycemic control, less disease burden and improved health-related quality of life (HRQoL). However, it is not clear for which subgroups of patients isCGM is cost-effective. We aimed to provide a real-world cost-effectiveness perspective. Methods: We used clinical data from a 1-year nationwide Dutch prospective observational study (N = 381) and linked these to insurance records. Health-related quality of life was assessed with the EQ-5D-3L questionnaire. Individuals were categorized into 4 subgroups: (1) frequent hypoglycemic events (58%), (2) HbA1c > 70 mmol/mol (8.5%) (19%), (3) occupation that requires avoiding finger pricks and/or hypoglycemia (5%), and (4) multiple indications (18%). Comparing costs and outcomes 12 months before and after isCGM initiation, incremental cost-effectiveness ratios (ICERs) were calculated for the total cohort and each subgroup from a societal perspective (including healthcare and productivity loss costs) at the willingness to pay of <euro>50,000 per quality-adjusted life year (QALY) gained. Results: From a societal perspective, isCGM was dominant in all subgroups (ie higher HRQoL gain with lower costs) except for subgroup 1. From a healthcare payer perspective, the probabilities of isCGM being cost-effective were 16%, 9%, 30%, 98%, and 65% for the total cohort and subgroup 1, 2, 3, and 4, respectively. Most sensitivity analyses confirmed these findings. Conclusions: Comparing subgroups of isCGM users allows to prioritize them based on cost-effectiveness. The most cost-effective subgroup was occupation-related indications, followed by multiple indications, high HbA1c and the frequent hypoglycemic events subgroups. However, controlled studies with larger sample size are needed to draw definitive conclusions.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 50 条
  • [31] Impact of intermittently scanned continuous glucose monitoring with alarms on sleep and metabolic outcomes in children and adolescents with type 1 diabetes
    Franceschi, Roberto
    Scotton, Chiara
    Leonardi, Letizia
    Cauvin, Vittoria
    Maines, Evelina
    Angriman, Marco
    Pertile, Riccardo
    Valent, Francesca
    Soffiati, Massimo
    Faraguna, Ugo
    ACTA DIABETOLOGICA, 2022, 59 (07) : 911 - 919
  • [32] Early Initiation of Intermittently Scanned Continuous Glucose Monitoring in a Pediatric Population With Type 1 Diabetes: A Real World Study
    Franceschi, Roberto
    Cauvin, Vittoria
    Stefani, Lorenza
    Berchielli, Federica
    Soffiati, Massimo
    Maines, Evelina
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [33] Impact of intermittently scanned continuous glucose monitoring with alarms on sleep and metabolic outcomes in children and adolescents with type 1 diabetes
    Roberto Franceschi
    Chiara Scotton
    Letizia Leonardi
    Vittoria Cauvin
    Evelina Maines
    Marco Angriman
    Riccardo Pertile
    Francesca Valent
    Massimo Soffiati
    Ugo Faraguna
    Acta Diabetologica, 2022, 59 : 911 - 919
  • [34] COST-EFFECTIVENESS ANALYSIS OF REAL-TIME CONTINUOUS GLUCOSE MONITORING (RTCGM) VS SELFMONITORING OF BLOOD GLUCOSE (SMBG) IN PATIENTS WITH TYPE 1 DIABETES IN THE NETHERLANDS
    Isitt, J.
    Cogswell, G.
    Alshannaq, H.
    Lynch, P.
    Norman, G. J.
    Roze, S.
    VALUE IN HEALTH, 2022, 25 (12) : S97 - S97
  • [35] Comparison of glycaemic metrics from simultaneous use of intermittently scanned and real-time continuous glucose monitoring in patients with type 1 diabetes
    Siolos, A.
    Christou, M.
    Katsarou, D.
    Christou, P.
    Zessides, C.
    Georga, E.
    Fotiadis, D.
    Tigas, S.
    DIABETOLOGIA, 2023, 66 (SUPPL 1) : S411 - S411
  • [36] Cost-effectiveness of G5 Mobile continuous glucose monitoring device compared to self-monitoring of blood glucose alone for people with type 1 diabetes from the Canadian societal perspective
    Chaugule, Shraddha
    Graham, Claudia
    JOURNAL OF MEDICAL ECONOMICS, 2017, 20 (11) : 1128 - 1135
  • [37] Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes
    Norgaard, Sidse Kjaerhus
    Mathiesen, Elisabeth Reinhardt
    Norgaard, Kirsten
    Ringholm, Lene
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (10) : 665 - 672
  • [38] In type 1 diabetes, real-time vs. intermittently scanned continuous glucose monitoring improved glycemic control
    Olson, Darin E.
    ANNALS OF INTERNAL MEDICINE, 2021, 174 (10) : JC119 - JC119
  • [39] Intermittently scanned continuous glucose monitoring in adults with type 1 diabetes: A subgroup analysis from the FLASH-UK study
    Leelarathna, Lalantha
    Sutton, Christopher J.
    Evans, Mark L.
    Neupane, Sankalpa
    Rayman, Gerry
    Lumley, Sarah
    Cranston, Iain
    Narendran, Parth
    Krishan, Ashma
    Taxiarchi, Vicky P.
    Barnard-Kelly, Katharine
    Elliott, Rachel A.
    Burns, Matthew
    Camm, Maisie
    Thabit, Hood
    Wilmot, Emma G.
    DIABETIC MEDICINE, 2024, 41 (03)
  • [40] Cost–utility analysis of Dexcom G6 real-time continuous glucose monitoring versus FreeStyle Libre 1 intermittently scanned continuous glucose monitoring in adults with type 1 diabetes in Belgium
    Margaretha M. Visser
    Astrid Van Muylder
    Sara Charleer
    John J. Isitt
    Stéphane Roze
    Christophe De Block
    Toon Maes
    Gerd Vanhaverbeke
    Frank Nobels
    Bart Keymeulen
    Chantal Mathieu
    Jeroen Luyten
    Pieter Gillard
    Nick Verhaeghe
    Diabetologia, 2024, 67 : 650 - 662