Personalizing the Use of a Intermittently Scanned Continuous Glucose Monitoring Device in Individuals With Type 1 Diabetes: A Cost-Effectiveness Perspective in the Netherlands (FLARE-NL 9)

被引:5
|
作者
Emamipour, Sajad [1 ]
van Dijk, Peter R. [2 ]
Bilo, Henk J. G. [3 ,4 ]
Edens, Mireille A. [5 ]
van der Galien, Onno [6 ]
Postma, Maarten J. [7 ,8 ]
Feenstra, Talitha L. [9 ,10 ]
van Boven, Job F. M. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Clin Pharm & Pharmacol, Hanzepl 1, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Endocrinol, Groningen, Netherlands
[3] Isala, Diabet Ctr, Zwolle, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Internal Med, Groningen, Netherlands
[5] Isala, Dept Innovat & Sci, Zwolle, Netherlands
[6] Achmea, Zeist, Netherlands
[7] Univ Groningen, Univ Med Ctr Groningen, Dept Hlth Sci, Groningen, Netherlands
[8] Univ Groningen, Fac Econ & Business, Dept Econ Econometr & Finance, Groningen, Netherlands
[9] Univ Groningen, Groningen Res Inst Pharm, Fac Sci & Engn, Groningen, Netherlands
[10] Natl Inst Publ Hlth & Environm RIVM, Bilthoven, Netherlands
来源
关键词
cost-effectiveness analysis; hypoglycemia; intermittently scanned continuous glucose monitoring; type 1 diabetes mellitus;
D O I
10.1177/19322968221109841
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Intermittently scanned continuous glucose monitoring (isCGM) is a method to monitor glucose concentrations without using a finger prick. Among persons with type 1 diabetes (T1D), isCGM results in improved glycemic control, less disease burden and improved health-related quality of life (HRQoL). However, it is not clear for which subgroups of patients isCGM is cost-effective. We aimed to provide a real-world cost-effectiveness perspective. Methods: We used clinical data from a 1-year nationwide Dutch prospective observational study (N = 381) and linked these to insurance records. Health-related quality of life was assessed with the EQ-5D-3L questionnaire. Individuals were categorized into 4 subgroups: (1) frequent hypoglycemic events (58%), (2) HbA1c > 70 mmol/mol (8.5%) (19%), (3) occupation that requires avoiding finger pricks and/or hypoglycemia (5%), and (4) multiple indications (18%). Comparing costs and outcomes 12 months before and after isCGM initiation, incremental cost-effectiveness ratios (ICERs) were calculated for the total cohort and each subgroup from a societal perspective (including healthcare and productivity loss costs) at the willingness to pay of <euro>50,000 per quality-adjusted life year (QALY) gained. Results: From a societal perspective, isCGM was dominant in all subgroups (ie higher HRQoL gain with lower costs) except for subgroup 1. From a healthcare payer perspective, the probabilities of isCGM being cost-effective were 16%, 9%, 30%, 98%, and 65% for the total cohort and subgroup 1, 2, 3, and 4, respectively. Most sensitivity analyses confirmed these findings. Conclusions: Comparing subgroups of isCGM users allows to prioritize them based on cost-effectiveness. The most cost-effective subgroup was occupation-related indications, followed by multiple indications, high HbA1c and the frequent hypoglycemic events subgroups. However, controlled studies with larger sample size are needed to draw definitive conclusions.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 50 条
  • [21] Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes
    McQueen R.B.
    Ellis S.L.
    Campbell J.D.
    Nair K.V.
    Sullivan P.W.
    Cost Effectiveness and Resource Allocation, 9 (1)
  • [22] The importance of education for diabetes control in patients with type 1 diabetes using intermittently scanned continuous glucose monitoring
    Bem, R.
    Vavra, D.
    Hladikova, Z.
    Maskova, J.
    Havlova, V.
    Lachmanova, Z.
    Sochorova, K.
    DIABETOLOGIA, 2022, 65 (SUPPL 1) : S337 - S337
  • [23] Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysis
    Moser, Othmar
    Sternad, Christoph
    Eckstein, Max L.
    Szadkowska, Agnieszka
    Michalak, Arkadiusz
    Mader, Julia K.
    Ziko, Haris
    Elsayed, Hesham
    Aberer, Felix
    Sola-Gazagnes, Agnes
    Larger, Etienne
    Fadini, Gian Poalo
    Bonora, Benedetta Maria
    Bruttomesso, Daniela
    Boscari, Federico
    Freckmann, Guido
    Pleus, Stefan
    Christiansen, Sverre C.
    Sourij, Harald
    DIABETES OBESITY & METABOLISM, 2022, 24 (03): : 522 - 529
  • [24] To evaluate the use and clinical effect of intermittently scanned continuous glucose monitoring in adults with type 1 diabetes: Results of a multicentre study
    Moreno-Fernandez, Jesus
    Sastre, Julia
    Pines, Pedro
    Calderon-Vicente, Dulce
    Gargallo, Javier
    Munoz-Rodriguez, Jose-Ramon
    ENDOCRINOLOGIA DIABETES Y NUTRICION, 2023, 70 (04): : 270 - 276
  • [25] Cost-Effectiveness of MiniMed 780G Therapy Compared with Multiple Daily Injections (MDI) with Intermittently Scanned Continuous Glucose Monitoring (isCGM) in People with Type 1 Diabetes (T1D)-A Singapore Perspective
    Gardner, Daphne
    Lakkad, Mrinmayee
    Qiu, Zhiyu
    Inoue, Yuta
    Chandran, Suresh Rama
    Wherry, Kael
    DIABETES, 2023, 72
  • [26] Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes
    Guo, Lixin
    Li, Yuxiu
    Zhang, Mei
    Xiao, Xinhua
    Kuang, Hongyu
    Yang, Tao
    Jia, Xiaofan
    Zhang, Xianbo
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [27] COST EFFECTIVENESS OF CONTINUOUS GLUCOSE MONITORING IN PEOPLE WITH TYPE 1 DIABETES
    Ljaljic, A.
    Yoels, B.
    Villa, Zapata L.
    VALUE IN HEALTH, 2023, 26 (06) : S101 - S101
  • [28] Glycemic Variability and Hypoglycemic Excursions With Continuous Glucose Monitoring Compared to Intermittently Scanned Continuous Glucose Monitoring in Adults With Highest Risk Type 1 Diabetes
    Avari, Parizad
    Moscardo, Vanessa
    Jugnee, Narvada
    Oliver, Nick
    Reddy, Monika
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (03): : 567 - 574
  • [30] A systematic review: Cost-effectiveness of continuous glucose monitoring compared to self-monitoring of blood glucose in type 1 diabetes
    Jiao, Yuxin
    Lin, Rose
    Hua, Xinyang
    Churilov, Leonid
    Gaca, Michele J.
    James, Steven
    Clarke, Philip M.
    O'Neal, David
    Ekinci, Elif, I
    ENDOCRINOLOGY DIABETES & METABOLISM, 2022, 5 (06)