Identification of the Distal Dural Ring Using Three-dimensional Spin Echo Imaging: Application to Paraclinoid Aneurysms

被引:0
|
作者
Oki, Maya [1 ]
Oki, Tatsuya [1 ]
Ito, Ryuta [1 ]
Roberts, Neil [1 ]
Watanabe, Yoshiyuki [1 ]
机构
[1] Shiga Univ Med Sci, Dept Radiol, Seta Tsukinowa Cho, Otsu, Shiga 5202192, Japan
关键词
distal dural ring; fast imaging employing steady state acquisition; motion-sensitized driven- equilibrium preparation; paraclinoid aneurysm; CISTERNOGRAPHY; ANGIOGRAPHY; DIAGNOSIS; FLOW;
D O I
10.2463/mrms.mp.2024-0084
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigated the ability of three-dimentional motion-sensitized driven-equilibrium prepared T1-weighted fast spin echo (3D MSDE-FSE) imaging to identify distal dural rings (DDRs) and paraclinoid aneurysms (ParaC-ANs) and differentiate between intradural and extradural ParaC-ANs and compared it with that of established MR cisternography-based techniques. Methods: 3D MSDE-FSE images were acquired along with fast imaging employing steady state acquisition (FIESTA), and time-of-flight magnetic resonance angiography (TOF-MRA) on a 3T MRI system in 53 patients with unruptured and untreated ParaC-ANs. Two radiologists applied a 3-point scale to rate the clarity with which the DDR (53 left and 53 right) and ParaC-ANs (total of 55) were depicted in the 3D MSDE-FSE and FIESTA images. The clarity scores, which were determined by averaging the scores of the 2 assessors, on the 3D MSDE-FSE and FIESTA images were compared using the Wilcoxon signedrank test. Furthermore, the same radiologists classified the ParaC-ANs as intradural, extradural, or transitional on 3D MSDE-FSE images. A third radiologist independently classified the ParaC-ANs as intradural, extradural, or transitional based on the FIESTA and MRA fusion images. The kappa coefficient was used to compare this classification with that based on 3D MSDE-FSE images. Results: The Wilcoxon signed-rank test revealed no significant difference between 3D MSDE-FSE images and FIESTA images in the scores for the clarity of depiction of the DDRs (P = 0.119). However, the scores for the clarity of the depiction of the ParaC-ANs were significantly greater for the 3D MSDE-FSE images than for the FIESTA images (P < 0.001). The kappa coefficient for comparison of classification based on 3D MSDE-FSE images and FIESTA and MRA fusion images was 0.82. Conclusion: 3D MSDE-FSE imaging has the potential to differentiate between intradural and extradural ParaC-ANs by directly recognizing the DDR.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Three-dimensional fast recovery fast spin-echo imaging of the inner ear and the vestibulocochlear nerve
    Nakashima, K
    Morikawa, M
    Ishimaru, H
    Ochi, M
    Kabasawa, H
    Hayashi, K
    EUROPEAN RADIOLOGY, 2002, 12 (11) : 2776 - 2780
  • [42] 3.0-T Evaluation of Knee Cartilage by Using Three-Dimensional IDEAL GRASS Imaging: Comparison with Fast Spin-Echo Imaging
    Kijowski, Richard
    Blankenbaker, Donna G.
    Woods, Michael A.
    Shinki, Kazuhiko
    De Smet, Arthur A.
    Reeder, Scott B.
    RADIOLOGY, 2010, 255 (01) : 117 - 127
  • [43] Spectrally Resolved Fully Phase-Encoded Three-Dimensional Fast Spin-Echo Imaging
    Artz, Nathan S.
    Hernando, Diego
    Taviani, Valentina
    Samsonov, Alexey
    Brittain, Jean H.
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 681 - 690
  • [44] Three-dimensional fast recovery fast spin-echo imaging of the inner ear and the vestibulocochlear nerve
    K. Nakashima
    M. Morikawa
    H. Ishimaru
    M. Ochi
    H. Kabasawa
    K. Hayashi
    European Radiology, 2002, 12 : 2776 - 2780
  • [45] Three-dimensional gradient echo versus spin echo sequence in contrast-enhanced imaging of the pituitary gland at 3 T
    Kakite, Suguru
    Fujii, Shinya
    Kurosaki, Masamichi
    Kanasaki, Yoshiko
    Matsusue, Eiji
    Kaminou, Toshio
    Ogawa, Toshihide
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (01) : 108 - 112
  • [46] Delineation of cerebral aneurysms with transluminal imaging of three-dimensional MRA
    Satoh, T
    NEUROLOGICAL SURGERY, 2001, 29 (10): : 951 - 959
  • [47] Evaluation of Intraneural Ganglion Cysts Using Three-Dimensional Fast Spin Echo-Cube
    Shahid, Kameron R.
    Spinner, Robert J.
    Skinner, John A.
    Felmlee, Joel P.
    Bond, Jeffrey R.
    Stanley, David W.
    Amrami, Kimberly K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (03) : 714 - 718
  • [48] Cervical fast spin echo three-dimensional magnetic resonance myelography
    Ishii, M
    Oda, N
    Takahagi, S
    Shibata, S
    Yoshizumi, T
    NEUROLOGIA MEDICO-CHIRURGICA, 1998, 38 (10) : 641 - 646
  • [49] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Zhang, Jing
    Chen, Lang
    Wang, Qiu-Xia
    Liu, Rong
    Zhu, Wen-Zhen
    Luo, Xin
    Peng, Li
    Xiong, Wei
    NEURORADIOLOGY, 2015, 57 (04) : 357 - 365
  • [50] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Jing Zhang
    Lang Chen
    Qiu-Xia Wang
    Rong Liu
    Wen-Zhen Zhu
    Xin Luo
    Li Peng
    Wei Xiong
    Neuroradiology, 2015, 57 : 357 - 365