Identification of the Distal Dural Ring Using Three-dimensional Spin Echo Imaging: Application to Paraclinoid Aneurysms

被引:0
|
作者
Oki, Maya [1 ]
Oki, Tatsuya [1 ]
Ito, Ryuta [1 ]
Roberts, Neil [1 ]
Watanabe, Yoshiyuki [1 ]
机构
[1] Shiga Univ Med Sci, Dept Radiol, Seta Tsukinowa Cho, Otsu, Shiga 5202192, Japan
关键词
distal dural ring; fast imaging employing steady state acquisition; motion-sensitized driven- equilibrium preparation; paraclinoid aneurysm; CISTERNOGRAPHY; ANGIOGRAPHY; DIAGNOSIS; FLOW;
D O I
10.2463/mrms.mp.2024-0084
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigated the ability of three-dimentional motion-sensitized driven-equilibrium prepared T1-weighted fast spin echo (3D MSDE-FSE) imaging to identify distal dural rings (DDRs) and paraclinoid aneurysms (ParaC-ANs) and differentiate between intradural and extradural ParaC-ANs and compared it with that of established MR cisternography-based techniques. Methods: 3D MSDE-FSE images were acquired along with fast imaging employing steady state acquisition (FIESTA), and time-of-flight magnetic resonance angiography (TOF-MRA) on a 3T MRI system in 53 patients with unruptured and untreated ParaC-ANs. Two radiologists applied a 3-point scale to rate the clarity with which the DDR (53 left and 53 right) and ParaC-ANs (total of 55) were depicted in the 3D MSDE-FSE and FIESTA images. The clarity scores, which were determined by averaging the scores of the 2 assessors, on the 3D MSDE-FSE and FIESTA images were compared using the Wilcoxon signedrank test. Furthermore, the same radiologists classified the ParaC-ANs as intradural, extradural, or transitional on 3D MSDE-FSE images. A third radiologist independently classified the ParaC-ANs as intradural, extradural, or transitional based on the FIESTA and MRA fusion images. The kappa coefficient was used to compare this classification with that based on 3D MSDE-FSE images. Results: The Wilcoxon signed-rank test revealed no significant difference between 3D MSDE-FSE images and FIESTA images in the scores for the clarity of depiction of the DDRs (P = 0.119). However, the scores for the clarity of the depiction of the ParaC-ANs were significantly greater for the 3D MSDE-FSE images than for the FIESTA images (P < 0.001). The kappa coefficient for comparison of classification based on 3D MSDE-FSE images and FIESTA and MRA fusion images was 0.82. Conclusion: 3D MSDE-FSE imaging has the potential to differentiate between intradural and extradural ParaC-ANs by directly recognizing the DDR.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Numerical analysis of three-dimensional echo decorrelation imaging
    Cox, Michael T.
    Abbass, Mohamed A.
    Mast, T. Douglas
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 147 (06): : EL478 - EL483
  • [32] Volumetric Arterial Spin-labeled Perfusion Imaging of the Kidneys with a Three-dimensional Fast Spin Echo Acquisition
    Robson, Philip M.
    Madhuranthakam, Ananth J.
    Smith, Martin P.
    Sun, Maryellen R. M.
    Dai, Weiying
    Rofsky, Neil M.
    Pedrosa, Ivan
    Alsop, David C.
    ACADEMIC RADIOLOGY, 2016, 23 (02) : 144 - 154
  • [33] Three-dimensional coronary MR angiography using zonal echo planar imaging
    Yang, GZ
    Gatehouse, PD
    Keegan, J
    Mohiaddin, RH
    Firmin, DN
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (05) : 833 - 842
  • [34] Three-dimensional ultrashort echo-time imaging using a FLORET trajectory
    Robison, Ryan K.
    Anderson, Ashley G., III
    Pipe, James G.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 1038 - 1049
  • [35] Optimized single-slab three-dimensional spin-echo MR imaging of the brain
    Mugler, JP
    Bao, SM
    Mulkern, RV
    Guttmann, CRG
    Robertson, RL
    Jolesz, FA
    Brookeman, JR
    RADIOLOGY, 2000, 216 (03) : 891 - 899
  • [36] Impact and Application of Echo Broadening Effect on Three-dimensional Range-gated Imaging
    Wang Xinwei
    Zhou Yan
    Liu Yuliang
    OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY II, 2012, 8558
  • [37] Three-dimensional identification of biological microorganism using integral imaging
    Javidi, Bahram
    Moon, Inkyu
    Yeom, Seokwon
    OPTICS EXPRESS, 2006, 14 (25) : 12096 - 12108
  • [38] Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing
    Lee, Seung Hyun
    Lee, Young Han
    Song, Ho-Taek
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2017, 42 : 152 - 157
  • [39] Optimized Three-Dimensional Fast-Spin-Echo MRI
    Mugler, John P., III
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (04) : 745 - 767
  • [40] Comparison of three-dimensional fast spin echo and gradient echo sequences for high-resolution temporal bone imaging
    Schmalbrock, P
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (06) : 814 - 825