Identification of the Distal Dural Ring Using Three-dimensional Spin Echo Imaging: Application to Paraclinoid Aneurysms

被引:0
|
作者
Oki, Maya [1 ]
Oki, Tatsuya [1 ]
Ito, Ryuta [1 ]
Roberts, Neil [1 ]
Watanabe, Yoshiyuki [1 ]
机构
[1] Shiga Univ Med Sci, Dept Radiol, Seta Tsukinowa Cho, Otsu, Shiga 5202192, Japan
关键词
distal dural ring; fast imaging employing steady state acquisition; motion-sensitized driven- equilibrium preparation; paraclinoid aneurysm; CISTERNOGRAPHY; ANGIOGRAPHY; DIAGNOSIS; FLOW;
D O I
10.2463/mrms.mp.2024-0084
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigated the ability of three-dimentional motion-sensitized driven-equilibrium prepared T1-weighted fast spin echo (3D MSDE-FSE) imaging to identify distal dural rings (DDRs) and paraclinoid aneurysms (ParaC-ANs) and differentiate between intradural and extradural ParaC-ANs and compared it with that of established MR cisternography-based techniques. Methods: 3D MSDE-FSE images were acquired along with fast imaging employing steady state acquisition (FIESTA), and time-of-flight magnetic resonance angiography (TOF-MRA) on a 3T MRI system in 53 patients with unruptured and untreated ParaC-ANs. Two radiologists applied a 3-point scale to rate the clarity with which the DDR (53 left and 53 right) and ParaC-ANs (total of 55) were depicted in the 3D MSDE-FSE and FIESTA images. The clarity scores, which were determined by averaging the scores of the 2 assessors, on the 3D MSDE-FSE and FIESTA images were compared using the Wilcoxon signedrank test. Furthermore, the same radiologists classified the ParaC-ANs as intradural, extradural, or transitional on 3D MSDE-FSE images. A third radiologist independently classified the ParaC-ANs as intradural, extradural, or transitional based on the FIESTA and MRA fusion images. The kappa coefficient was used to compare this classification with that based on 3D MSDE-FSE images. Results: The Wilcoxon signed-rank test revealed no significant difference between 3D MSDE-FSE images and FIESTA images in the scores for the clarity of depiction of the DDRs (P = 0.119). However, the scores for the clarity of the depiction of the ParaC-ANs were significantly greater for the 3D MSDE-FSE images than for the FIESTA images (P < 0.001). The kappa coefficient for comparison of classification based on 3D MSDE-FSE images and FIESTA and MRA fusion images was 0.82. Conclusion: 3D MSDE-FSE imaging has the potential to differentiate between intradural and extradural ParaC-ANs by directly recognizing the DDR.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Direct Imaging of the Distal Dural Ring and Paraclinoid Internal Carotid Artery Aneurysms With Magnetic Resonance Imaging
    Mertol, Tansu
    Al Anazi, Abdulrahman
    Al Muazen, Yahya
    NEUROSURGERY, 2010, 67 (03) : E878 - U361
  • [2] MRI location of the distal dural ring plane: anatomoradiological study and application to paraclinoid carotid artery aneurysms
    Thines, L
    Delmaire, C
    Le Gars, D
    Pruvo, JP
    Lejeune, JP
    Lehmann, P
    Francke, JP
    EUROPEAN RADIOLOGY, 2006, 16 (02) : 479 - 488
  • [3] MRI location of the distal dural ring plane: anatomoradiological study and application to paraclinoid carotid artery aneurysms
    Laurent Thines
    Christine Delmaire
    Daniel Le Gars
    Jean-Pierre Pruvo
    Jean-Paul Lejeune
    Pierre Lehmann
    Jean-Paul Francke
    European Radiology, 2006, 16 : 479 - 488
  • [4] Identification of the Distal Dural Ring with Use of Fusion Images with 3D-MR Cisternography and MR Angiography: Application to Paraclinoid Aneurysms
    Watanabe, Y.
    Nakazawa, T.
    Yamada, N.
    Higashi, M.
    Hishikawa, T.
    Miyamoto, S.
    Naito, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (04) : 845 - 850
  • [5] Distance Between the Falciform Ligament and Distal Dural Ring as a Surgical Landmark for the Treatment of Paraclinoid Aneurysms
    Matsumoto, Masaki
    Mizutani, Tohru
    Sugiyama, Tatsuya
    Sumi, Kenji
    Nakajo, Takato
    Arai, Shintaro
    WORLD NEUROSURGERY, 2019, 124 : E498 - E502
  • [6] Identification of the Distal Dural Ring and Definition of Paraclinoid Aneurysms According to Bony Landmarks on 3-Dimensional Computed Tomography Angiography: A Cadaveric and Radiological Study
    Scerbak, Jelena
    Lapteva, Ona
    Sahin, Omer S.
    Ksanas, Ugnius
    Barkauskiene, Alina
    Lengvenis, Givi
    Ozaydin, Burak
    Cikla, Ulas
    Baskaya, Mustafa K.
    OPERATIVE NEUROSURGERY, 2020, 19 (03) : 319 - 329
  • [7] DIRECT IMAGING OF THE DISTAL DURAL RING AND PARACLINOID INTERNAL CAROTID ARTERY ANEURYSMS WITH HIGH-RESOLUTION T2 TURBO-SPIN ECHO TECHNIQUE AT 3-T MAGNETIC RESONANCE IMAGING
    Thines, Laurent
    Lee, Seon Kyu
    Dehdashti, Amir R.
    Agid, Ronit
    Willinsky, Robert A.
    Wallace, Christopher M.
    Terbrugge, Karel G.
    NEUROSURGERY, 2009, 64 (06) : 1059 - 1064
  • [8] In Reply: Identification of the Distal Dural Ring and Definition of Paraclinoid Aneurysms According to Bony Landmarks on 3-Dimensional Computed Tomography Angiography: A Cadaveric and Radiological Study
    Scerbak, Jelena
    Baskaya, Mustafa K.
    OPERATIVE NEUROSURGERY, 2020, 19 (05) : E548 - E549
  • [9] DIRECT IMAGING OF THE DISTAL DURAL RING AND PARACLINOID INTERNAL CAROTID ARTERY ANEURYSMS WITH HIGH-RESOLUTION T2 TURBO-SPIN ECHO TECHNIQUE AT 3-T MAGNETIC RESONANCE IMAGING COMMENTS
    Lawton, Michael T.
    Lavine, Sean D.
    Schackert, Gabriele
    NEUROSURGERY, 2009, 64 (06) : 1064 - 1064