The Validity and Usability of Markerless Motion Capture and Inertial Measurement Units for Quantifying Dynamic Movements

被引:0
|
作者
Edwards, Nathan a. [1 ,2 ]
Caccese, Jaclyn b. [1 ,2 ]
Tracy, Ryan e. [2 ]
Hagen, Joshua [1 ,2 ,3 ]
Quatman-yates, Catherine c. [2 ]
Onate, James [1 ,2 ]
机构
[1] Ohio State Univ, Human Performance Collaborat, Columbus, OH USA
[2] Ohio State Univ, Sch Hlth & Rehabil Sci, Columbus, OH USA
[3] Ohio State Univ, Integrated Syst Engn, Columbus, OH USA
关键词
BIOMECHANICS; KINEMATICS; MOTION ANALYSIS; MOVEMENT ASSESSMENT; WEARABLE SENSORS; JOINT COORDINATE SYSTEM; ISB RECOMMENDATION; CENTER LOCATION; LOWER-EXTREMITY; GAIT; HIP; RELIABILITY; KNEE; DEFINITIONS; PERFORMANCE;
D O I
10.1249/MSS.0000000000003579
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
PurposeMotion capture technology is quickly evolving, providing researchers, clinicians, and coaches with more access to biomechanics data. Markerless motion capture and inertial measurement units (IMUs) are continually developing biomechanics tools that need validation for dynamic movements before widespread use in applied settings. This study evaluated the validity of a markerless motion capture, IMU, and red, green, blue, and depth (RGBD) camera system as compared with marker-based motion capture during countermovement jumps, overhead squats, lunges, and runs with cuts.MethodsThirty adults were recruited for this study (sex: 18 females, 12 males; age: 25.4 +/- 8.6 yrs; height: 1.71 +/- 0.08 m; weight: 71.6 +/- 11.5 kg). Data were collected simultaneously with four motion capture technologies (i.e., Vicon, marker-based; Theia/Optitrack, markerless; APDM Opals, IMUs; and Vald HumanTrak, RGBD camera). System validity for lower and upper body joint angles was evaluated using bias, root mean squared error (RMSE), precision, maximum absolute error, and intraclass correlation coefficients. System usability was descriptively analyzed.ResultsOverall, markerless motion capture had the highest validity (sagittal plane RMSE: 3.20 degrees-15.66 degrees; frontal plane RMSE: 2.12 degrees-9.14 degrees; transverse plane RMSE: 3.160 degrees-56.61 degrees), followed by the IMU system (sagittal plane RMSE: 8.11 degrees-28.37 degrees; frontal plane RMSE: 3.26 degrees-16.98 degrees; transverse plane RMSE: 5.08 degrees-116.75 degrees), and lastly the RGBD system (sagittal plane bias: 0.55 degrees-129.48 degrees; frontal plane bias: 1.35 degrees-52.06 degrees).ConclusionsMarkerless motion capture and IMUs have moderate validity for joint kinematics, whereas the RGBD system did not have adequate validity. Markerless systems have lower data processing time, require moderate technical expertise, but have high data storage size. IMUs are easier to use, can collect data in any location, but require participant set-up. Overall, individuals using motion capture should consider the specific movements, testing locations, and technical expertise available before selecting a system.
引用
收藏
页码:641 / 655
页数:15
相关论文
共 50 条
  • [41] A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation
    Lam, Winnie W. T.
    Tang, Yuk Ming
    Fong, Kenneth N. K.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2023, 20 (01)
  • [42] Concurrent validity of inertial measurement units in range of motion measurements of upper extremity: A systematic review and meta-analysis
    Li, Jinfeng
    Qiu, Fanji
    Gan, Liaoyan
    Chou, Li-Shan
    WEARABLE TECHNOLOGIES, 2024, 5
  • [43] Comparison Of Different Clothing Conditions With Markerless Motion Capture During A Dynamic Landing Task
    Valencia, Matthew P.
    Ross, Kaley
    Pexa, Brett
    Johnston, Christopher
    Taylor, Jeffrey B.
    Ford, Kevin R.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 63 - 63
  • [44] Quantifying jumps and external load in netball using VERT inertial measurement units
    Brooks, Edward R.
    Benson, Amanda C.
    Fox, Aaron S.
    Bruce, Lyndell M.
    SPORTS BIOMECHANICS, 2021,
  • [45] PHOTOGRAMMETRIC MONITORING OF GRAVITATIONAL MASS MOVEMENTS IN ALPINE REGIONS BY MARKERLESS 3D MOTION CAPTURE
    Lucks, Lukas
    Hirt, Philipp-Roman
    Hoegner, Ludwig
    Stilla, Uwe
    XXIV ISPRS CONGRESS IMAGING TODAY, FORESEEING TOMORROW, COMMISSION II, 2022, 43-B2 : 1063 - 1069
  • [46] Validity of time series kinematical data as measured by a markerless motion capture system on a flatland for gait assessment
    Tanaka, Ryo
    Takimoto, Haruka
    Yamasaki, Takahiro
    Higashi, Ariaki
    JOURNAL OF BIOMECHANICS, 2018, 71 : 281 - 285
  • [47] Analysis of Inertial Measurement Units Performances Under Dynamic Conditions
    Patrizi, Gabriele
    Carratu, Marco
    Ciani, Lorenzo
    Sommella, Paolo
    Catelani, Marcantonio
    Pietrosanto, Antonio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [48] Concurrent validity and test reliability of the deep learning markerless motion capture system during the overhead squat
    Bae, Kyungun
    Lee, Seyun
    Bak, Se-Young
    Kim, Hyo Sang
    Ha, Yuncheol
    You, Joshua H.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [49] Classification of movements of collegiate female soccer players using inertial measurement units
    Masui, Yuki
    Hirotsu, Nobuyoshi
    Shimasaki, Yu
    Yoshimura, Masafumi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2024,
  • [50] Tracking limbs motion using a wireless network of inertial measurement units
    Buonocunto, Pasquale
    Marinoni, Mauro
    2014 9TH IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL EMBEDDED SYSTEMS (SIES), 2014,