The Validity and Usability of Markerless Motion Capture and Inertial Measurement Units for Quantifying Dynamic Movements

被引:0
|
作者
Edwards, Nathan a. [1 ,2 ]
Caccese, Jaclyn b. [1 ,2 ]
Tracy, Ryan e. [2 ]
Hagen, Joshua [1 ,2 ,3 ]
Quatman-yates, Catherine c. [2 ]
Onate, James [1 ,2 ]
机构
[1] Ohio State Univ, Human Performance Collaborat, Columbus, OH USA
[2] Ohio State Univ, Sch Hlth & Rehabil Sci, Columbus, OH USA
[3] Ohio State Univ, Integrated Syst Engn, Columbus, OH USA
关键词
BIOMECHANICS; KINEMATICS; MOTION ANALYSIS; MOVEMENT ASSESSMENT; WEARABLE SENSORS; JOINT COORDINATE SYSTEM; ISB RECOMMENDATION; CENTER LOCATION; LOWER-EXTREMITY; GAIT; HIP; RELIABILITY; KNEE; DEFINITIONS; PERFORMANCE;
D O I
10.1249/MSS.0000000000003579
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
PurposeMotion capture technology is quickly evolving, providing researchers, clinicians, and coaches with more access to biomechanics data. Markerless motion capture and inertial measurement units (IMUs) are continually developing biomechanics tools that need validation for dynamic movements before widespread use in applied settings. This study evaluated the validity of a markerless motion capture, IMU, and red, green, blue, and depth (RGBD) camera system as compared with marker-based motion capture during countermovement jumps, overhead squats, lunges, and runs with cuts.MethodsThirty adults were recruited for this study (sex: 18 females, 12 males; age: 25.4 +/- 8.6 yrs; height: 1.71 +/- 0.08 m; weight: 71.6 +/- 11.5 kg). Data were collected simultaneously with four motion capture technologies (i.e., Vicon, marker-based; Theia/Optitrack, markerless; APDM Opals, IMUs; and Vald HumanTrak, RGBD camera). System validity for lower and upper body joint angles was evaluated using bias, root mean squared error (RMSE), precision, maximum absolute error, and intraclass correlation coefficients. System usability was descriptively analyzed.ResultsOverall, markerless motion capture had the highest validity (sagittal plane RMSE: 3.20 degrees-15.66 degrees; frontal plane RMSE: 2.12 degrees-9.14 degrees; transverse plane RMSE: 3.160 degrees-56.61 degrees), followed by the IMU system (sagittal plane RMSE: 8.11 degrees-28.37 degrees; frontal plane RMSE: 3.26 degrees-16.98 degrees; transverse plane RMSE: 5.08 degrees-116.75 degrees), and lastly the RGBD system (sagittal plane bias: 0.55 degrees-129.48 degrees; frontal plane bias: 1.35 degrees-52.06 degrees).ConclusionsMarkerless motion capture and IMUs have moderate validity for joint kinematics, whereas the RGBD system did not have adequate validity. Markerless systems have lower data processing time, require moderate technical expertise, but have high data storage size. IMUs are easier to use, can collect data in any location, but require participant set-up. Overall, individuals using motion capture should consider the specific movements, testing locations, and technical expertise available before selecting a system.
引用
收藏
页码:641 / 655
页数:15
相关论文
共 50 条
  • [1] Dynamic Gaussian Splatting from Markerless Motion Capture Reconstruct Infants Movements
    Cotton, R. James
    Peyton, Colleen
    2024 IEEE WINTER CONFERENCE ON APPLICATIONS OF COMPUTER VISION WORKSHOPS, WACVW 2024, 2024, : 60 - 68
  • [2] Validity and Consistency of Concurrent Extraction of Gait Features Using Inertial Measurement Units and Motion Capture System
    Anwary, Arif Reza
    Yu, Hongnian
    Callaway, Andrew
    Vassallo, Michael
    IEEE SENSORS JOURNAL, 2021, 21 (02) : 1625 - 1634
  • [3] Markerless Motion Capture using Appearance and Inertial Data
    Wong, Charence
    Zhang, Zhiqiang
    Lo, Benny
    Yang, Guang-Zhong
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6907 - 6910
  • [4] Motion capture with inertial measurement units for hand/arm robot teleoperation
    Kobayashi, Futoshi
    Hasegawa, Ko
    Nakamoto, Hiroyuki
    Kojima, Fumio
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 45 (1-4) : 931 - 937
  • [5] Validity of inertial measurement units for tracking human motion: a systematic review
    Ghattas, John
    Jarvis, Danielle N.
    SPORTS BIOMECHANICS, 2021,
  • [6] Usability-Optimization of Inertial Motion Capture Systems
    Pomiersky, Philipp
    Karlovic, Kristian
    Maier, Thomas
    PROCEEDINGS OF THE 20TH CONGRESS OF THE INTERNATIONAL ERGONOMICS ASSOCIATION (IEA 2018), VOL VII: ERGONOMICS IN DESIGN, DESIGN FOR ALL, ACTIVITY THEORIES FOR WORK ANALYSIS AND DESIGN, AFFECTIVE DESIGN, 2019, 824 : 345 - 355
  • [7] Riding Motion Capture System Using Inertial Measurement Units with Contact Constraints
    Maruyama, Tsubasa
    Tada, Mitsunori
    Toda, Haruki
    INTERNATIONAL JOURNAL OF AUTOMATION TECHNOLOGY, 2019, 13 (04) : 506 - 516
  • [8] Dynamic accuracy of inertial measurement units during simple pendulum motion
    Brodie, M. A.
    Walmsley, A.
    Page, W.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 (03) : 235 - 242
  • [9] Quantifying Jump Height Using Markerless Motion Capture with a Single Smartphone
    Aderinola, Timilehin B.
    Younesian, Hananeh
    Whelan, Darragh
    Caulfield, Brian
    Ifrim, Georgiana
    IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY, 2023, 4 : 109 - 115
  • [10] Validity of Markerless Motion Capture System and Its Correlation with Physical Characteristics for Hip Range of Motion Measurement: A Pilot Study
    Bak, Se-Young
    Ahn, Junghoon
    Choi, Hongtaek
    Lee, Seunghee
    Lim, Wootaek
    Kim, Hyeong-Dong
    SENSORS AND MATERIALS, 2025, 37 (03) : 965 - 976