Determination of Ventilatory Thresholds Using Near-Infrared Spectroscopy in Recreational Endurance and CrossFit Athletes

被引:1
|
作者
Arnet, Janik [1 ]
Knaier, Raphael [1 ]
Schoch, Raphael [1 ]
D'Hulst, Gommaar [2 ]
Bruggisser, Fabienne [1 ]
Feldmann, Andri [3 ]
Leuenberger, Rahel [1 ]
Westerhuis, Elena [1 ]
Infanger, Denis [1 ]
Schmidt-Trucksass, Arno [1 ]
Wagner, Jonathan [1 ]
机构
[1] Univ Basel, Fac Med, Dept Sport Exercise & Hlth, Basel, Switzerland
[2] Swiss Fed Inst Technol, Hlth Sci & Technol, Zurich, Switzerland
[3] Univ Bern, Inst Sport Sci, Bern, Switzerland
关键词
training zones; NIRS; fitness testing; wearables; critical power; MUSCLE OXYGEN-SATURATION; TRAINED CYCLISTS; CRITICAL POWER; EXERCISE; RELIABILITY; COMPENSATION; BREAKPOINTS; AGREEMENT;
D O I
10.1123/ijspp.2024-0265
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
To define training zones, ventilatory thresholds (VTs) are commonly established by cardiopulmonary gas-exchange analysis during incremental exercise tests. Portable near-infrared spectroscopy (NIRS) devices have emerged as a potential tool for detecting these thresholds by monitoring muscle oxygenation. This study evaluated the accuracy of NIRS measurements to determine VTs or critical power (CP) based on muscle oxygen saturation and assesses the device's consistency across 2 constant-load tests. Data from 2 crosssectional studies involving trained recreational endurance athletes (26 from study 1) and CrossFit athletes (59 from study 2) were examined. Incremental ramp tests on a cycle ergometer were performed and followed by either a constant-load test (study 1) or a CP test (study 2). When comparing power output or heart rate between NIRS-derived breakpoints and VTs, weak to moderate agreement was found. Mean differences in power output and heart rate ranged from 16.8 to 22.4 W and 3.8 to 6.0 beats-min-1 at the first threshold and 27.4 to 31.2 W and 7.1 to 7.8 beats-min-1 at the second threshold. Comparing with CP, mean differences ranged from -0.4 to 0.4 W and -0.6 to 0.9 beats-min-1. Test-retest reliability showed moderate agreement, with a mean bias of 1.2 percentage points between constant-load tests. Thus, NIRS may not be accurate for determining VTs or CP during exercise due to limited agreement in power output or hear rate, notable variability on individual level, and moderate reproducibility.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Rapid determination of Panax ginseng by near-infrared spectroscopy
    Bu Haibo
    Nie Lixing
    Wang Dan
    Yuan Shaoxiong
    Li Shan
    Guo Zhiyong
    Xu Xiaojia
    Wang Gangli
    Li Xiangri
    ANALYTICAL METHODS, 2013, 5 (23) : 6715 - 6721
  • [42] Near-infrared spectroscopy
    Misra, M
    Alp, MS
    Dujovny, M
    Ausman, JI
    JOURNAL OF NEUROSURGERY, 1996, 85 (02) : 363 - 363
  • [43] Near-infrared spectroscopy
    Tsuchikawa, S
    Hayashi, K
    Tsutsumi, S
    APPLIED SPECTROSCOPY, 1996, 50 (09) : 1117 - 1124
  • [44] NEAR-INFRARED SPECTROSCOPY
    HARRIS, DNF
    ANAESTHESIA, 1995, 50 (12) : 1015 - 1016
  • [45] DETERMINATION OF HYDROXYL VALUE OF ALCOHOLS BY NEAR-INFRARED SPECTROSCOPY
    CRISLER, RO
    BURRILL, AM
    ANALYTICAL CHEMISTRY, 1959, 31 (12) : 2055 - 2057
  • [46] DETERMINATION OF IODINE VALUE BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    INGBER, NM
    KALKA, DS
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1984, 61 (04) : 652 - 652
  • [47] Near-infrared spectroscopy
    Norris, T
    Aldridge, PK
    Sekulic, SS
    ANALYST, 1997, 122 (06) : 549 - 552
  • [48] NEAR-INFRARED SPECTROSCOPY
    EDWARDS, AD
    EUROPEAN JOURNAL OF PEDIATRICS, 1995, 154 (08) : S19 - S21
  • [49] Near-infrared spectroscopy
    Ramsay, SJ
    Gomersall, CD
    ANAESTHESIA, 2002, 57 (06) : 615 - 616
  • [50] Determination of Ribavirin and Moisture in Pharmaceuticals by Near-Infrared Spectroscopy
    Yang, Hongqin
    Liu, Yanxin
    Huang, Yanmei
    Tang, Bin
    Guo, Dan
    Li, Hui
    ANALYTICAL LETTERS, 2016, 49 (13) : 2077 - 2091