Determination of Ventilatory Thresholds Using Near-Infrared Spectroscopy in Recreational Endurance and CrossFit Athletes

被引:1
|
作者
Arnet, Janik [1 ]
Knaier, Raphael [1 ]
Schoch, Raphael [1 ]
D'Hulst, Gommaar [2 ]
Bruggisser, Fabienne [1 ]
Feldmann, Andri [3 ]
Leuenberger, Rahel [1 ]
Westerhuis, Elena [1 ]
Infanger, Denis [1 ]
Schmidt-Trucksass, Arno [1 ]
Wagner, Jonathan [1 ]
机构
[1] Univ Basel, Fac Med, Dept Sport Exercise & Hlth, Basel, Switzerland
[2] Swiss Fed Inst Technol, Hlth Sci & Technol, Zurich, Switzerland
[3] Univ Bern, Inst Sport Sci, Bern, Switzerland
关键词
training zones; NIRS; fitness testing; wearables; critical power; MUSCLE OXYGEN-SATURATION; TRAINED CYCLISTS; CRITICAL POWER; EXERCISE; RELIABILITY; COMPENSATION; BREAKPOINTS; AGREEMENT;
D O I
10.1123/ijspp.2024-0265
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
To define training zones, ventilatory thresholds (VTs) are commonly established by cardiopulmonary gas-exchange analysis during incremental exercise tests. Portable near-infrared spectroscopy (NIRS) devices have emerged as a potential tool for detecting these thresholds by monitoring muscle oxygenation. This study evaluated the accuracy of NIRS measurements to determine VTs or critical power (CP) based on muscle oxygen saturation and assesses the device's consistency across 2 constant-load tests. Data from 2 crosssectional studies involving trained recreational endurance athletes (26 from study 1) and CrossFit athletes (59 from study 2) were examined. Incremental ramp tests on a cycle ergometer were performed and followed by either a constant-load test (study 1) or a CP test (study 2). When comparing power output or heart rate between NIRS-derived breakpoints and VTs, weak to moderate agreement was found. Mean differences in power output and heart rate ranged from 16.8 to 22.4 W and 3.8 to 6.0 beats-min-1 at the first threshold and 27.4 to 31.2 W and 7.1 to 7.8 beats-min-1 at the second threshold. Comparing with CP, mean differences ranged from -0.4 to 0.4 W and -0.6 to 0.9 beats-min-1. Test-retest reliability showed moderate agreement, with a mean bias of 1.2 percentage points between constant-load tests. Thus, NIRS may not be accurate for determining VTs or CP during exercise due to limited agreement in power output or hear rate, notable variability on individual level, and moderate reproducibility.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Determination of soybean routine quality parameters using near-infrared spectroscopy
    Zhu, Zhenying
    Chen, Shangbing
    Wu, Xueyou
    Xing, Changrui
    Yuan, Jian
    FOOD SCIENCE & NUTRITION, 2018, 6 (04): : 1109 - 1118
  • [32] Quantitative determination and classification of energy drinks using near-infrared spectroscopy
    Racz, Anita
    Heberger, Karoly
    Fodor, Marietta
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (23) : 6403 - 6411
  • [33] Quantitative Determination of Parameters of Substrate Using Near-Infrared Spectroscopy Technique
    Yu Yong-hua
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (11) : 2928 - 2931
  • [34] Determination of Sucrose Content in Soybean Using Near-infrared Reflectance Spectroscopy
    Myoung-Gun Choung
    Journal of the Korean Society for Applied Biological Chemistry, 2010, 53 (4): : 478 - 484
  • [35] Determination of camelina seed weight using near-infrared reflectance spectroscopy
    Vollmann, J
    Damboeck, A
    Kuyt, SJH
    Ruckenbauer, P
    PLANT VARIETIES AND SEEDS, 1997, 10 (02): : 95 - 101
  • [36] Assessment of ventilatory threshold using near-infrared spectroscopy on the gastrocnemius muscle during treadmill running
    Karatzanos, Eleftherios
    Paradisis, Georgios
    Zacharogiannis, Elias
    Tziortzis, Stavros
    Nanas, Serafim
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2010, 40 (02) : 206 - 211
  • [37] Determination of sodium alginate in algae by near-infrared spectroscopy
    Xu, Peilong
    Na, Na
    Gao, Shouwu
    Geng, Cunzhen
    DESALINATION AND WATER TREATMENT, 2019, 168 : 117 - 122
  • [38] Quantitative determination of water in γ-cyclodextrin by near-infrared spectroscopy
    Viernstein, H
    Weiss-Greiler, P
    Wolschann, P
    PHARMAZEUTISCHE INDUSTRIE, 2005, 67 (01): : 122 - 125
  • [39] Gossypol determination by near-infrared reflectance spectroscopy.
    不详
    POULTRY SCIENCE, 2004, 83 (10) : 1779 - 1779
  • [40] Near-infrared spectroscopy for fast determination of biomass components
    Liu, Hanbin
    Sun, Lan
    Li, Chenlin
    Varanasi, Patanjali
    Arora, Rohit
    Cheng, Gang
    Simmons, Blake A.
    Singh, Seema
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242