A novel flat rectangular evaporator with the optimized heat leakage paths to improve the heat transfer capability of the loop heat pipe

被引:0
|
作者
Ma, Zhengyuan [1 ]
Zhang, Zikang [2 ]
Tan, Yubo [1 ]
Liu, Wei [1 ]
Liu, Zhichun [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
[2] Beijing Inst Astronaut Syst Engn, Beijing 100076, Peoples R China
关键词
Loop heat pipe; Flat evaporator; Heat leakage; Heat transfer experiments; OPERATIONAL CHARACTERISTICS; PERFORMANCE; LHP;
D O I
10.1016/j.applthermaleng.2025.126171
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat leakage from the evaporator can cause the loop heat pipes (LHPs) to fail to start up or reduce their heat transfer performance, limiting the application of LHPs. To promote the application of LHPs in the thermal management of ground electronics, it is necessary to solve the adverse effects of heat leakage on the heat transfer performance. In this paper, a novel evaporator structure that reduces heat leakage to the compensation chamber (CC) is proposed, while utilizing heat leakage through the shell to extend the heating surface. The evaporator features bifacial heating surfaces sharing the same CC and vapor chamber. It was tested in the horizontal direction to evaluate thermal performance in three different heating modes. When the bottom heat source 1 (HS1) was individually heated. As the heat load increased, the LHP transitioned from a variable thermal conductivity mode to a constant thermal conductivity mode, and finally, the wick approached dry-out conditions, resulting in a sharp increase in the temperature of the heat source. When the top heat source 2 (HS2) was individually heated. The heat transfer performance of LHP was improved and the evaporator inlet temperature remained low. Gravity assisted vapor escaped upwards, maintaining a stable temperature and pressure difference over the wick, enabling the LHP to dissipate a heat load of up to 300 W with the heat source temperature remaining below 80 degrees C. When HS2 and HS1 were simultaneously heated with equal heat load of 80 W. The bifacial heating surfaces of the evaporator switched from a heat extension relationship to a heat sharing relationship, and the difference in the temperature between the bifacial heating surfaces was less than 0.3 degrees C when the LHP was operating stably. Under the same heat load, the thermal resistance of LHP was the lowest when HS2 was individually heated, ranging from 0.536 degrees C/W to 0.216 degrees C/W, and the minimum value was reached at heat load of 250 W.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] MECHANISM OF HEAT TRANSFER IN EVAPORATOR ZONE OF A HEAT PIPE
    FERRELL, JK
    JOHNSON, HR
    MECHANICAL ENGINEERING, 1970, 92 (11) : 60 - &
  • [42] Numerical simulation of transient heat and mass transfer in a cylindrical evaporator of a loop heat pipe
    Chernysheva, M. A.
    Maydanik, Yu. F.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (17-18) : 4204 - 4215
  • [43] Experimental study on flat type loop heat pipe with parallel evaporator
    Liu, Z.-C. (zcliu@hust.edu.cn), 1939, Science Press (34):
  • [44] Investigation of the Thermal Characteristics of a Flat Bifacial Evaporator Loop Heat Pipe
    Chen, Yang
    Feng, Daili
    Miao, Jianyin
    Zhang, Hongxing
    Feng, Yanhui
    Liu, Chenpeng
    HEAT TRANSFER ENGINEERING, 2022, 43 (13) : 1097 - 1107
  • [45] Ceramic flat plate evaporator for loop heat pipe cooling of electronics
    Zimbeck, Walter
    Chaney, Jared
    Espinoza, Patricio
    Kroliczek, Edward
    Bugby, David C.
    Yuri, James
    Advances in Electronic Packaging 2005, Pts A-C, 2005, : 177 - 182
  • [46] Experimental tests of a stainless steel loop heat pipe with flat evaporator
    Celata, Gian Piero
    Cumo, Maurizio
    Furrer, Massimo
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (07) : 866 - 878
  • [47] Miniature loop heat pipe with flat evaporator for cooling computer CPU
    Singh, Randeep
    Akbarzadeh, Aliakbar
    Dixon, Chris
    Mochizuki, Mastaka
    Riehl, Roger R.
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2007, 30 (01): : 42 - 49
  • [48] Experimental study of an ammonia loop heat pipe with a flat plate evaporator
    Song, He
    Liu Zhi-chun
    Jing, Zhao
    Chi, Jiang
    Yang Jin-guo
    Wei, Liu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 102 : 1050 - 1055
  • [49] Characteristics of temperature oscillation in miniature loop heat pipe with flat evaporator
    Gai, Dongxing
    Liu, Zhichun
    Liu, Wei
    Yang, Jinguo
    Huagong Xuebao/CIESC Journal, 2009, 60 (06): : 1390 - 1397
  • [50] Evaporative heat transfer analysis of a micro loop heat pipe with rectangular grooves
    Ghajar, M.
    Darabi, J.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 79 : 51 - 59