A novel flat rectangular evaporator with the optimized heat leakage paths to improve the heat transfer capability of the loop heat pipe

被引:0
|
作者
Ma, Zhengyuan [1 ]
Zhang, Zikang [2 ]
Tan, Yubo [1 ]
Liu, Wei [1 ]
Liu, Zhichun [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
[2] Beijing Inst Astronaut Syst Engn, Beijing 100076, Peoples R China
关键词
Loop heat pipe; Flat evaporator; Heat leakage; Heat transfer experiments; OPERATIONAL CHARACTERISTICS; PERFORMANCE; LHP;
D O I
10.1016/j.applthermaleng.2025.126171
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat leakage from the evaporator can cause the loop heat pipes (LHPs) to fail to start up or reduce their heat transfer performance, limiting the application of LHPs. To promote the application of LHPs in the thermal management of ground electronics, it is necessary to solve the adverse effects of heat leakage on the heat transfer performance. In this paper, a novel evaporator structure that reduces heat leakage to the compensation chamber (CC) is proposed, while utilizing heat leakage through the shell to extend the heating surface. The evaporator features bifacial heating surfaces sharing the same CC and vapor chamber. It was tested in the horizontal direction to evaluate thermal performance in three different heating modes. When the bottom heat source 1 (HS1) was individually heated. As the heat load increased, the LHP transitioned from a variable thermal conductivity mode to a constant thermal conductivity mode, and finally, the wick approached dry-out conditions, resulting in a sharp increase in the temperature of the heat source. When the top heat source 2 (HS2) was individually heated. The heat transfer performance of LHP was improved and the evaporator inlet temperature remained low. Gravity assisted vapor escaped upwards, maintaining a stable temperature and pressure difference over the wick, enabling the LHP to dissipate a heat load of up to 300 W with the heat source temperature remaining below 80 degrees C. When HS2 and HS1 were simultaneously heated with equal heat load of 80 W. The bifacial heating surfaces of the evaporator switched from a heat extension relationship to a heat sharing relationship, and the difference in the temperature between the bifacial heating surfaces was less than 0.3 degrees C when the LHP was operating stably. Under the same heat load, the thermal resistance of LHP was the lowest when HS2 was individually heated, ranging from 0.536 degrees C/W to 0.216 degrees C/W, and the minimum value was reached at heat load of 250 W.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Experimental investigation for the loop heat pipe with a bifacial flat evaporator
    Wang, Tingting
    Zhao, Jing
    Liu, Wei
    Ma, Lei
    Liu, Zhichun
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 200
  • [32] EXPERIMENTAL STUDY ON HEAT TRANSFER CAPABILITY OF A MINIATURE LOOP HEAT PIPE
    Zhou, Guohui
    Li, Ji
    Lv, Lucang
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 8, 2017,
  • [33] A novel design and experimental study of a cryogenic loop heat pipe with high heat transfer capability
    Mo, Q
    Liang, JT
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (3-4) : 770 - 776
  • [34] Analysis of Flow and Heat Transfer in Evaporator Porous Wicking Structure of a Flat Heat Pipe
    Hu, Congxiang
    Peng, Xiaofeng
    HEAT TRANSFER-ASIAN RESEARCH, 2009, 38 (02): : 92 - 100
  • [35] Analysis of flow and heat transfer in the evaporator porous wick structure of a flat heat pipe
    Lab. of Phasechange and Interfacial Transport Phenomena, Department of Thermal Engineering, Tsinghua University, Beijing 100084, China
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2007, 28 (SUPPL. 2): : 21 - 24
  • [36] Experimental study on a novel loop heat pipe with both flat evaporator and boiling pool
    Lu, Xiao
    Wei, Jin-Jia
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 79 : 54 - 63
  • [37] Operating characteristics of an anti-gravity loop heat pipe with a flat evaporator that has the capability of a loop thermosyphon
    Watanabe, Noriyuki
    Nguyen Phan
    Saito, Yuki
    Hayashi, Shota
    Katayama, Naoki
    Nagano, Hosei
    ENERGY CONVERSION AND MANAGEMENT, 2020, 205
  • [38] Operating characteristics of a flat evaporator loop heat pipe having a flexible heat transport path
    Lee, Joohyun
    Joung, Wukchul
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2022, 36 (07) : 3735 - 3751
  • [39] Operating characteristics of a flat evaporator loop heat pipe having a flexible heat transport path
    Joohyun Lee
    Wukchul Joung
    Journal of Mechanical Science and Technology, 2022, 36 (7) : 3735 - 3751
  • [40] Numerical study of flow and heat transfer in the vapour grooves of a loop heat pipe evaporator
    Fravallo, Pierre-Yves
    Prat, Marc
    Platel, Vincent
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 171