Measurement and Analysis of Surface Temperature Gradients on Magnetron Sputtered Thin Film Growth Studied Using NiCr/NiSi Thin Film Thermocouples

被引:1
|
作者
Liu, Zhihui [1 ,2 ]
Yang, Yumeng [3 ]
Sun, Yi [1 ]
Guo, Tengda [2 ]
Shen, Kai [1 ]
Cheng, Yongjun [4 ]
Wang, Bi [5 ]
Hu, Kai [2 ]
Zhang, Chuanbing [2 ]
Hao, Gang [1 ]
Zhou, Jiankang [2 ]
Wu, Mengxuan [2 ]
Cui, Baoli [2 ]
Ding, Wanyu [1 ]
Wang, Zixi [2 ]
机构
[1] Dalian Jiaotong Univ, Coll Mat Sci & Engn, Dalian 116028, Peoples R China
[2] Tsinghua Univ, State Key Lab Tribol Adv Equipment, Beijing 100084, Peoples R China
[3] Suzhou Univ Sci & Technol, Sch Mech Engn, Suzhou 215009, Jiangsu, Peoples R China
[4] CSSC, Lab Low Frequency Electromagnet Commun Technol 722, Wuhan 430200, Peoples R China
[5] State Key Lab High end Compressor & Syst Technol, Hefei 230031, Anhui, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
film growth surface temperature; magnetron sputtering; NiCr/NiSi thin film thermocouple; static calibration; SEEBECK COEFFICIENT; SIZE;
D O I
10.1002/smll.202404829
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the general analysis of thin-film growth processes, it is often assumed that the temperature of the film growth surface is the same as the temperature of the film growth substrate. However, a temperature gradient exists between the film growth surface and film growth substrate. Using the growth surface of TiO2 thin films as an example, the temperature gradient of the film growth surface is tested and analyzed. A NiCr/NiSi thin-film thermocouple is fabricated using the direct-current pulse magnetron sputtering method. A three-layer NiCr/NiSi thin-film thermocouple temperature measurement system is established to measure the temperature gradient of the film growth surface. The growth surface temperature and substrate temperature of the TiO2 thin films are measured. For a sputtering power density of 0.83 W cm-2, the temperature difference between the first and second layers is 104.79 degrees C, while the temperature difference between the second and third layers is 39.92 degrees C. A standard K-type thermocouple is used to measure the substrate temperature, which is recorded to be 132.05 degrees C, consistent with common measurements of substrate temperature. The heat conduction on the film growth surface in the vacuum chamber is examined and a model for the temperature measurement device during film growth is constructed. The growth surface temperature and substrate temperature of a TiO2 thin film are measured by NiCr/NiSi thin-film and standard K-type patch thermocouples. In the process of TiO2 thin-film deposition, the absorption of heat energy mainly occurs on the film growth surface. A large temperature gradient exists from the film growth surface to the film growth substrate. The film growth surface temperature is considerably higher than the substrate temperature. Combined with the surface temperature of TiO2 film growth, the surface temperature of film growth has a crucial role. image
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Built-in thin film thermocouples in surface textures of cemented carbide tools for cutting temperature measurement
    Li, Jindang
    Tao, Bo
    Huang, Shuwen
    Yin, Zhouping
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 279 : 663 - 670
  • [32] Effect of Hot Junction Size on the Temperature Measurement of Proton Exchange Membrane Fuel Cells Using NiCr/NiSi Thin-Film Thermocouple Sensors
    Guo, Huijin
    Liu, Zhihui
    Guo, Tengda
    Sun, Yi
    Shen, Kai
    Wang, Bi
    Cheng, Yongjun
    Wang, Yuming
    Ma, Tiancai
    Wang, Zixi
    Ding, Wanyu
    MICROMACHINES, 2024, 15 (11)
  • [33] Investigation of Sulfurization Effect on Magnetron Sputtered CZTS Thin Film
    Kumar, Hemant
    Agrawal, Sagar
    Rane, Ramkrishna
    Mukherjee, Subroto
    Pradhan, Basudev
    DAE SOLID STATE PHYSICS SYMPOSIUM 2018, 2019, 2115
  • [34] A new fabrication method of NiCr/NiSi thin-film thermocouple sensor for workpiece temperature measurement in chemical explosive material machining
    Zeng, Qiyong
    Sun, Baoyuan
    Deng, Xinlu
    Xu, Jun
    WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 8374 - 8377
  • [35] Temperature-driven spin reorientation transition of magnetron sputtered nickel thin film
    宋小会
    张殿琳
    Chinese Physics B, 2008, (09) : 3495 - 3498
  • [36] Temperature-driven spin reorientation transition of magnetron sputtered nickel thin film
    Song Xiao-Hui
    Zhang Dian-Lin
    CHINESE PHYSICS B, 2008, 17 (09) : 3495 - 3498
  • [37] Enhanced thermoelectric property and stability of NiCr–NiSi thin film thermocouple on superalloy substrate
    Xiao-Hui Zhao
    Yi-Ran Wang
    Yin-Zhi Chen
    Hong-Chuan Jiang
    Wan-Li Zhang
    Rare Metals, 2017, 36 (06) : 512 - 516
  • [38] Enhanced thermoelectric property and stability of NiCr–NiSi thin film thermocouple on superalloy substrate
    Xiao-Hui Zhao
    Yi-Ran Wang
    Yin-Zhi Chen
    Hong-Chuan Jiang
    Wan-Li Zhang
    Rare Metals, 2017, 36 : 512 - 516
  • [39] Transient temperature measurement in nanosecond pulsed laser micro drilling by using micro thin film thermocouples
    Choi, Hongseok
    Li, Xiaochun
    MANUFACTURING ENGINEERING AND MATERIALS HANDLING, 2005 PTS A AND B, 2005, 16 : 499 - 502
  • [40] Cutting tools embedded with thin film thermocouples vertically to the rake face for temperature measurement
    Li, Jindang
    Tao, Bo
    Huang, Shuwen
    Yin, Zhouping
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 296 : 392 - 399