Comparative Accuracy of Stationary and Smartphone-Based Photogrammetry in Oral and Maxillofacial Surgery: A Clinical Study

被引:1
|
作者
Seifert, Lukas B. [1 ,2 ,3 ]
Beyer, Michel [2 ,3 ]
Czok, Vanessa [1 ]
Aigner, Alexander [2 ,3 ]
Abazi, Sead [2 ,3 ]
Thieringer, Florian M. [2 ,3 ]
Sader, Robert [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Oral Cranio Maxillofacial & Facial Plast Surg, Theodor Stern Kai 7, D-60528 Frankfurt, Germany
[2] Univ Hosp Basel, Clin Oral & Cranio Maxillofacial Surg, CH-4031 Basel, Switzerland
[3] Univ Basel, Dept Biomed Engn, Med Addit Mfg Res Grp Swiss MAM, CH-4123 Allschwil, Switzerland
关键词
3D scanning; facial scanning; smartphone; TOMOGRAPHY;
D O I
10.3390/jcm13226678
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Three-dimensional facial scan technologies, such as stereophotogrammetry, are frequently used in oral and maxillofacial surgery, dentistry, and plastic surgery to assess patient outcomes and plan surgical procedures. Most facial scanners rely on stationary clinical systems, which provide high accuracy and reliability in generating 3D representations of the human face; however, they are cost-intensive and immobile. Recently, smartphone-based facial scan applications that use stereophotogrammetry have been developed. These applications are cost-effective and more accessible than existing stationary systems. Methods: In this study, we compared the accuracy of three different smartphone applications-EM3D, Polycam, and ScandyPro-on an iPhone 14 Pro, which utilizes Apple's LiDAR (Light Detection and Ranging) technology, to a stationary system by 3DMD, which is considered a gold standard in many studies. Results: The applications included in the study have demonstrated the capability to perform accurately in clinical settings, with mean surface distances of 1.46 mm for EM3D, 1.66 mm for Polycam, and 1.61 mm for ScandyPro. Conclusions: These results suggest that smartphone-based facial scan systems could be a viable alternative, particularly in resource-limited settings. However, further research and collaboration between academia and industry are necessary to fully integrate these technologies into clinical practice.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Accuracy of a smartphone-based orthodontic treatment-monitoring application: A pilot study
    Moylan, Heather B.
    Carrico, Caroline K.
    Lindauer, Steven J.
    Tufekci, Eser
    ANGLE ORTHODONTIST, 2019, 89 (05) : 727 - 733
  • [22] A Novel Device for Smartphone-Based Fundus Imaging and Documentation in Clinical Practice: Comparative Image Analysis Study
    Wintergerst, Maximilian W. M.
    Jansen, Linus G.
    Holz, Frank G.
    Finger, Robert P.
    JMIR MHEALTH AND UHEALTH, 2020, 8 (07):
  • [23] Smartphone-Based Patient Education in Plastic Surgery
    Noel, Warren
    Bosc, Romain
    Jabbour, Samer
    Kechichian, Elio
    Hersant, Barbara
    Meningaud, Jean-Paul
    ANNALS OF PLASTIC SURGERY, 2017, 79 (06) : 529 - 531
  • [24] A Comparative Study on the Use of Smartphone Cameras in Photogrammetry Applications
    Patonis, Photis
    SENSORS, 2024, 24 (22)
  • [25] Low-Cost Smartphone-Based Photogrammetry for the Analysis of Cranial Deformation in Infants
    Barbero-Garcia, Ines
    Lerma, Jose Luis
    Marques-Mateu, Angel
    Miranda, Pablo
    WORLD NEUROSURGERY, 2017, 102 : 545 - 554
  • [26] Smartphone-Based Photogrammetry Assessment in Comparison with a Compact Camera for Construction Management Applications
    Saif, Wahib
    Alshibani, Adel
    APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [27] A Pilot Study of a Smartphone-Based Tonometer
    Wen, Joanne C.
    Luttrell, Ian
    Chen, Philip P.
    Feng, Shu
    Spaide, Ted
    Wu, Yue
    Lee, Aaron Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [28] Clinical study of octacalcium phosphate and collagen composite in oral and maxillofacial surgery
    Kawai, Tadashi
    Kamakura, Shinji
    Matsui, Keiko
    Fukuda, Masayuki
    Takano, Hiroshi
    Iino, Mitsuyoshi
    Ishikawa, Shigeo
    Kawana, Hiromasa
    Soma, Tomoya
    Imamura, Eisaku
    Kizu, Hideki
    Michibata, Aya
    Asahina, Izumi
    Miura, Keiichiro
    Nakamura, Norifumi
    Kibe, Toshiro
    Suzuki, Osamu
    Takahashi, Tetsu
    JOURNAL OF TISSUE ENGINEERING, 2020, 11
  • [29] A Smartphone-based System for Clinical Gait Assessment
    Perez, Andres A.
    Labrador, Miguel A.
    2016 IEEE INTERNATIONAL CONFERENCE ON SMART COMPUTING (SMARTCOMP), 2016, : 39 - 46
  • [30] Sensitivity and Specificity of Smartphone-Based Retinal Imaging for Diabetic Retinopathy A Comparative Study
    Sengupta, Sabyasachi
    Sindal, Manavi D.
    Baskaran, Prabu
    Pan, Utsab
    Venkatesh, Rengaraj
    OPHTHALMOLOGY RETINA, 2019, 3 (02): : 146 - 153