Energy and exergy analysis of a two-stage cascade vapor compression refrigeration system with modified system configuration

被引:0
|
作者
Patiluna, Dave Nygeil G. [1 ,2 ]
Donasco, Edgar Alan A. [2 ]
Hernandez, Noel M. [2 ]
Mamalias, Junil Bien A. [2 ]
Vina, Rommel R. [2 ]
机构
[1] Mindanao State Univ, Dept Mech Engn, Main Campus, Marawi City, Philippines
[2] Mindanao State Univ, Iligan Inst Technol MSU IIT, Dept Mech Engn, Iligan, Philippines
关键词
Cascade refrigeration system; Internal heat exchanger; Energy and exergy analysis; Ecop; Cop; Coefficient of performance; THERMODYNAMIC PERFORMANCE;
D O I
10.1016/j.ijrefrig.2024.10.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study proposes a modification to the two-stage cascade vapor compression refrigeration system by adding internal heat exchangers that function as subcoolers and desuperheater. The influence of each internal heat exchanger proposed on the exergy destruction rate, exergy efficiency, compressor power consumption, ECOP, and COP of the system was investigated. Additionally, various refrigerant combinations were considered as working fluids to evaluate which combination is the most suitable for the proposed system. Mathematical models based on the principles of thermodynamics were established in Engineering Equation Solver (EES), a software used for energy and exergy analysis. The results reveal that the addition of specific internal heat exchangers causes either an increase or decrease in overall system performance, depending on the type of refrigerant combination used. Consequently, there exists an optimal system configuration for each refrigerant combination. Compared with the conventional two-stage cascade refrigeration system, the optimal system configurations in the present study exhibited higher overall system performance. A maximum increase in exergy efficiency, ECOP, and COP of 7.31 %, 9.8 %, and 7.3 %, respectively, can be observed with the refrigerant combination R450A/ R404A. Additionally, the results of the exergy analysis identify that the HTC compressor, condenser, LTC compressor, and cascade condenser are the primary contributors to the exergy destruction rate within the system.
引用
收藏
页码:33 / 54
页数:22
相关论文
共 50 条
  • [41] A comprehensive energy, exergy, environmental, and economic analysis of dedicated mechanical subcooled vapor compression refrigeration system
    Solanki, Naveen
    Arora, Akhilesh
    Singh, Raj Kumar
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (03) : 1141 - 1154
  • [42] A comprehensive energy, exergy, environmental, and economic analysis of dedicated mechanical subcooled vapor compression refrigeration system
    Naveen Solanki
    Akhilesh Arora
    Raj Kumar Singh
    Journal of Thermal Analysis and Calorimetry, 2024, 149 : 1141 - 1154
  • [43] Exergy analysis for quasi two-stage compression heat pump system coupled with ejector
    Xu Shuxue
    Ma Guoyuan
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (04) : 700 - 705
  • [44] Interaction analysis of a two-stage refrigeration control system
    Asmar, BN
    Wilson, JA
    Jones, WE
    1997 JUBILEE RESEARCH EVENT, VOLS 1 AND 2, 1997, : 741 - 744
  • [45] COMPARISON OF ENERGY AND EXERGY EFFICIENCIES OF ABSORPTION REFRIGERATION SYSTEM WITH MECHANICAL COMPRESSION REFRIGERATION SYSTEM
    Yakar, Gulay
    Karabacak, Rasim
    Altan, Burcin Deda
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2005, 11 (02): : 161 - 169
  • [46] Cascade refrigeration system synthesis based on exergy analysis
    Zhang, Jian
    Xu, Qiang
    COMPUTERS & CHEMICAL ENGINEERING, 2011, 35 (09) : 1901 - 1914
  • [47] Energy and exergy analysis of a combined system: cascade organic Rankine cycle and cascade refrigeration cycle
    Rabah, Touaibi
    Koten, Hasan
    Fadhila, Boudjema
    Salma, Selmane
    Mohamed, Hemis
    JOURNAL OF THERMAL ENGINEERING, 2021, 7 (05): : 1139 - 1149
  • [48] ENERGY AND EXERGY ANALYSIS OF A VAPOR ABSORPTION REFRIGERATION SYSTEM IN AN INTERCITY BUS APPLICATION
    Kurtulmus, N.
    Bilgili, M.
    Sahin, B.
    JOURNAL OF THERMAL ENGINEERING, 2019, 5 (04): : 355 - 371
  • [49] Energy and exergy analysis of an integrated photovoltaic module and two-stage thermoelectric generator system
    Chen, Xingguo
    Huang, Yuewu
    Chen, Zhuo
    Applied Thermal Engineering, 2022, 212
  • [50] Energy and exergy analysis of an integrated photovoltaic module and two-stage thermoelectric generator system
    Chen, Xingguo
    Huang, Yuewu
    Chen, Zhuo
    APPLIED THERMAL ENGINEERING, 2022, 212