A comprehensive energy, exergy, environmental, and economic analysis of dedicated mechanical subcooled vapor compression refrigeration system

被引:0
|
作者
Naveen Solanki
Akhilesh Arora
Raj Kumar Singh
机构
[1] Maharaja Agrasen Institute of Technology,Mechanical Engineering Department
[2] Delhi Technological University,Mechanical Engineering Department
关键词
Energy; Exergy; Economic; Environment; Exergetic efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
In the modern world, the vapor compression refrigeration (VCR) system is essential in various global applications, including climate control, refrigeration, and food preservation, contributing significantly to energy consumption. The significant energy demands associated with these applications highlight the urgency for sustainable and energy-efficient alternatives that can help diminish our dependence on electrical power. To reduce energy consumption and enhance energy efficiency, a dedicated mechanical subcooled (DMS) system can be integrated with a vapor compression system (VCR) system. This study aims to evaluate and optimize the dedicated mechanical subcooled-vapor compressor refrigeration system (DMS-VCR) system using refrigerant R134a for a 100 kW commercial chiller used for water cooling application. The primary objective is to assess the system from multiple angles which include energy, exergy, environmental, economic analysis (4E’s) and optimizing it to enhance its overall effectiveness to reduce the system’s annual cost. It is thermo-economically optimized, allowing for independent optimization of the evaporator, condenser-1, condenser-2, and sub-cooler components. The proposed system reduces electrical energy consumption by 17.24% and CO2 emissions by 12.4%. The DMS-VCR system outperforms the standalone VCR system. The DMS-VCR system’s annual operating costs are 6.71% lower than an equivalent VCR system, and optimization further reduces costs by 1.88% (case-I: irate = 10%, Ny = 5 years, and toper = 4000 h) and 16.36% (case-II: irate = 2%, Ny = 10 years, and toper = 5000 h).The study underscores the importance of subcooling within the DMS-VCR system, highlighting its desirability as it varies with the recovery factor and annual operation period. As a result of the DMS-VCR system’s better efficiency, design engineers are likely to find it more attractive.
引用
收藏
页码:1141 / 1154
页数:13
相关论文
共 50 条
  • [1] A comprehensive energy, exergy, environmental, and economic analysis of dedicated mechanical subcooled vapor compression refrigeration system
    Solanki, Naveen
    Arora, Akhilesh
    Singh, Raj Kumar
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (03) : 1141 - 1154
  • [2] Advance exergy and coefficient of structural bond analysis of dedicated mechanical subcooled vapor compression refrigeration system
    Solanki, Naveen
    Arora, Akhilesh
    Singh, Raj Kumar
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 153 : 266 - 280
  • [3] A comprehensive parametric and structural bond analysis of an actual vapor compression refrigeration system with dedicated mechanical subcooled system
    Solanki, Naveen
    Arora, Akhilesh
    Singh, Raj Kumar
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2024, 38 (01) : 439 - 452
  • [4] A comprehensive parametric and structural bond analysis of an actual vapor compression refrigeration system with dedicated mechanical subcooled system
    Naveen Solanki
    Akhilesh Arora
    Raj Kumar Singh
    [J]. Journal of Mechanical Science and Technology, 2024, 38 : 439 - 452
  • [5] Performance enhancement and environmental analysis of vapor compression refrigeration system with dedicated mechanical subcooling
    Naveen Solanki
    Akhilesh Arora
    Raj Kumar Singh
    [J]. International Journal of Air-Conditioning and Refrigeration, 31
  • [6] Performance enhancement and environmental analysis of vapor compression refrigeration system with dedicated mechanical subcooling
    Solanki, Naveen
    Arora, Akhilesh
    Singh, Raj Kumar
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2023, 31 (01)
  • [7] Exergy, economic and environmental analysis of organic Rankine cycle based vapor compression refrigeration system
    Ashwni
    Sherwani, Ahmad Faizan
    Tiwari, Deepak
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 126 : 259 - 271
  • [8] Exergy Analysis of a Vapor Compression Refrigeration System
    Hou, Xiao-chen
    Zhao, Guo-chang
    Song, Li-ping
    Wang, Yong
    Mao, Xiao-dong
    Peng, Da-wei
    [J]. 2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 1817 - 1820
  • [9] Energy and Exergy Analysis of Vapor Compression Refrigeration System with Flooded Evaporator
    Okereke, Chukwuemeka J.
    Ohijeagbon, Idehai O.
    Lasode, Olumuyiwa A.
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2019, 27 (04)
  • [10] A review on exergy analysis of vapor compression refrigeration system
    Ahamed, J. U.
    Saidur, R.
    Masjuki, H. H.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03): : 1593 - 1600