The refractive accuracy between topographic keratometry and biometric keratometry for extended depth-of-focus intraocular lens implantation

被引:0
|
作者
Lee, Chia-Yi [1 ,2 ,3 ]
Yang, Shun-Fa [1 ,4 ]
Chen, Hung-Chi [5 ,6 ,7 ]
Lian, Ie-Bin [8 ]
Huang, Jing-Yang [4 ]
Chang, Chao-Kai [2 ,9 ]
机构
[1] Chung Shan Med Univ, Inst Med, Taichung, Taiwan
[2] Nobel Eye Inst, 13-5 Gongyuan Rd, Taipei 100008, Taiwan
[3] Jen Ai Hosp, Dept Ophthalmol, Dali Branch, Taichung, Taiwan
[4] Chung Shan Med Univ Hosp, Dept Med Res, Taichung, Taiwan
[5] Chang Gung Mem Hosp, Dept Ophthalmol, Linkou, Taiwan
[6] Chang Gung Mem Hosp, Ctr Tissue Engn, Linkou, Taiwan
[7] Chang Gung Univ, Dept Med, Coll Med, Taoyuan, Taiwan
[8] Natl Changhua Univ Educ, Inst Stat & Informat Sci, Changhua, Taiwan
[9] Yuanpei Univ Med Technol, Dept Optometry, Hsinchu, Taiwan
来源
关键词
extended depth-of-focus; topographic; biometric; astigmatism; angle kappa; ASTIGMATISM; POWER;
D O I
10.7150/ijms.99907
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To investigate the influence of different keratometry (K) measurements on the postoperative outcomes of cataract surgery with extended depth-of-focus (EDOF) intraocular lens (IOL) implantation. Methods: A retrospective cohort study was conducted, and patients who received cataract surgery and one type of EDOF IOL implantation were included. The patients were then categorized according to K measurements, and 70 and 30 eyes were included in the biometric-K and topographic-K groups, respectively. The primary outcomes were postoperative uncorrected distance visual acuity (UDVA), spherical equivalent (SE) and cylinder power. A generalized linear model was applied to compare the adjusted odds ratios (aORs) and 95% confidence intervals (CIs) of the outcomes between groups. Results: One month after surgery, the UDVA was 0.15 and 0.07 in the biometric-K group and topographic-K group, respectively. Furthermore, the final SEs were -0.42 D and -0.13 D in the biometric-K group and topographic-K group, respectively, and the final cylinder powers were -0.35 D and -0.13 D in the biometric-K group and topographic-K group, respectively. According to the multivariate analysis, the topographic-K group presented a significantly better UDVA (P = 0.044) and significantly lower cylinder power (P = 0.031) than the biometric-K group. Angle kappa was significantly correlated with high postoperative astigmatism in the topographic-K group (P = 0.033), whereas angle kappa, steep K, and corneal cylinder powers were significantly correlated with high postoperative astigmatism in the biometric-K group (all P < 0.05). Conclusion: Topography-based K measurements yielded better refractive outcomes than biometric-based K measurements did.
引用
收藏
页码:2912 / 2918
页数:7
相关论文
共 50 条
  • [31] Extended Depth-of-Focus Intraocular Lens Implantation in Patients with Age-Related Macular Degeneration: A Pilot Study
    Thananjeyan, Akshaya Lakshmi
    Siu, Anna
    Jennings, Angela
    Bala, Chandra
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 451 - 458
  • [32] Results of an Extended Depth-of-Focus Intraocular Lens Implantation in the Second Eye of Monofocal Pseudophakic Patients: A Pilot Study
    Shemesh, Rachel
    Reitblat, Olga
    Rodov, Luba
    Levy, Adi
    Assia, Ehud I.
    Kleinmann, Guy
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2023, 12 (04): : 349 - 354
  • [33] Visualoutcomesandsafety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
    Chang, Daniel H.
    Janakiraman, Devi Priya
    Smith, Pamela J.
    Buteyn, Anne
    Domingo, Joy
    Jones, Jason J.
    Christie, William C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (03): : 288 - 297
  • [34] Accuracy of refractive outcomes using standard or total keratometry for intraocular lens power formulas in conventional cataract surgery
    Zhao, He
    Chen, Xu
    Liu, Bo
    Liu, Xi
    Liu, Yong
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [35] Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery
    Wang, Li
    Spektor, Tatyana
    de Souza, Rodrigo G.
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1416 - 1421
  • [36] Clinical outcomes of a monofocal intraocular lens with enhanced intermediate function compared with an extended depth-of-focus intraocular lens
    Lee, Jae Hyuck
    Moon, Su Young
    Chung, Ho Seok
    Park, So Young
    Lee, Hun
    Kim, Jae Yong
    Tchah, Hungwon
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (01): : 61 - 66
  • [37] Accuracy of refractive outcomes using standard or total keratometry for intraocular lens power formulas in conventional cataract surgery
    He Zhao
    Xu Chen
    Bo Liu
    Xi Liu
    Yong Liu
    BMC Ophthalmology, 23 (1)
  • [38] COMPARISON OF THE ACCURACY OF COMPUTERIZED VIDEOKERATOGRAPHY AND KERATOMETRY FOR USE IN INTRAOCULAR-LENS CALCULATIONS
    CUAYCONG, MJ
    GAY, CA
    EMERY, J
    HAFT, EA
    KOCH, DD
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 : 178 - 181
  • [39] Accuracy of biometry using automated and manual keratometry for intraocular lens power calculation
    Khan, Lubna
    Sharma, Babita
    Gupta, Harshal
    Rana, Rimpi
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2018, 8 (02) : 93 - 98
  • [40] Tolerance to refractive error with a new extended depth of focus intraocular lens
    Black, Daniel A.
    Bala, Chandra
    Alarcon, Aixa
    Vilupuru, Srividhya
    EYE, 2024, 38 (SUPPL 1) : 15 - 20