The refractive accuracy between topographic keratometry and biometric keratometry for extended depth-of-focus intraocular lens implantation

被引:0
|
作者
Lee, Chia-Yi [1 ,2 ,3 ]
Yang, Shun-Fa [1 ,4 ]
Chen, Hung-Chi [5 ,6 ,7 ]
Lian, Ie-Bin [8 ]
Huang, Jing-Yang [4 ]
Chang, Chao-Kai [2 ,9 ]
机构
[1] Chung Shan Med Univ, Inst Med, Taichung, Taiwan
[2] Nobel Eye Inst, 13-5 Gongyuan Rd, Taipei 100008, Taiwan
[3] Jen Ai Hosp, Dept Ophthalmol, Dali Branch, Taichung, Taiwan
[4] Chung Shan Med Univ Hosp, Dept Med Res, Taichung, Taiwan
[5] Chang Gung Mem Hosp, Dept Ophthalmol, Linkou, Taiwan
[6] Chang Gung Mem Hosp, Ctr Tissue Engn, Linkou, Taiwan
[7] Chang Gung Univ, Dept Med, Coll Med, Taoyuan, Taiwan
[8] Natl Changhua Univ Educ, Inst Stat & Informat Sci, Changhua, Taiwan
[9] Yuanpei Univ Med Technol, Dept Optometry, Hsinchu, Taiwan
来源
关键词
extended depth-of-focus; topographic; biometric; astigmatism; angle kappa; ASTIGMATISM; POWER;
D O I
10.7150/ijms.99907
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To investigate the influence of different keratometry (K) measurements on the postoperative outcomes of cataract surgery with extended depth-of-focus (EDOF) intraocular lens (IOL) implantation. Methods: A retrospective cohort study was conducted, and patients who received cataract surgery and one type of EDOF IOL implantation were included. The patients were then categorized according to K measurements, and 70 and 30 eyes were included in the biometric-K and topographic-K groups, respectively. The primary outcomes were postoperative uncorrected distance visual acuity (UDVA), spherical equivalent (SE) and cylinder power. A generalized linear model was applied to compare the adjusted odds ratios (aORs) and 95% confidence intervals (CIs) of the outcomes between groups. Results: One month after surgery, the UDVA was 0.15 and 0.07 in the biometric-K group and topographic-K group, respectively. Furthermore, the final SEs were -0.42 D and -0.13 D in the biometric-K group and topographic-K group, respectively, and the final cylinder powers were -0.35 D and -0.13 D in the biometric-K group and topographic-K group, respectively. According to the multivariate analysis, the topographic-K group presented a significantly better UDVA (P = 0.044) and significantly lower cylinder power (P = 0.031) than the biometric-K group. Angle kappa was significantly correlated with high postoperative astigmatism in the topographic-K group (P = 0.033), whereas angle kappa, steep K, and corneal cylinder powers were significantly correlated with high postoperative astigmatism in the biometric-K group (all P < 0.05). Conclusion: Topography-based K measurements yielded better refractive outcomes than biometric-based K measurements did.
引用
收藏
页码:2912 / 2918
页数:7
相关论文
共 50 条
  • [21] Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery
    Yeo, Tun Kuan
    Heng, Wee Jin
    Pek, Don
    Wong, John
    Fam, Han Bor
    EYE, 2021, 35 (06) : 1705 - 1711
  • [22] Corneal topography and keratometry changes after glued intraocular lens implantation
    Kumar, Dhivya Ashok
    Kaur, Harspreet
    Agarwal, Amar
    Selvaraj, Sajitha
    Pandian, Sathish Kumar
    Chintalpati, Vamsi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (08): : 1062 - 1067
  • [23] Clinical Outcomes of a Refractive Extended Depth of Focus Intraocular Lens
    Orbegozo, Javier
    Perez, Angelica
    Basterra, Inaki
    Noguera, Helena
    Diaz, Sergio
    Gonzalez, Laura
    Lauzirika, Gorka
    Pinero, David P.
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (03) : e238 - e247
  • [24] Impact of measured total keratometry versus anterior keratometry on the refractive outcomes of the AT TORBI 709-MP toric intraocular lens
    Levron, Antoine
    El Chehab, Hussam
    Agard, Emilie
    Chudzinski, Roman
    Billant, Jeremy
    Dot, Corinne
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (05) : 1199 - 1207
  • [25] Influence of ocular biometric factors on the defocus curve in an enlarged depth-of-focus intraocular lens
    Gimenez-Calvo, Galadriel
    Bartol-Puyal, Francisco de Asis
    Altemir, Irene
    Mendez-Martinez, Silvia
    Almenara, Cristina
    Soriano-Pina, Diana
    Murueta-Goyena, Ane
    Larrosa, Jose Manuel
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (03) : 945 - 955
  • [26] Influence of ocular biometric factors on the defocus curve in an enlarged depth-of-focus intraocular lens
    Galadriel Giménez-Calvo
    Francisco de Asís Bartol-Puyal
    Irene Altemir
    Silvia Méndez-Martínez
    Cristina Almenara
    Diana Soriano-Pina
    Ane Murueta-Goyena
    José Manuel Larrosa
    International Ophthalmology, 2023, 43 : 945 - 955
  • [27] Refractive and Visual Outcomes After Implantation of a Secondary Sulcus Intraocular Lens with an Extended Depth of Focus
    Gundersen, Kjell Gunnar
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1861 - 1869
  • [28] Impact of measured total keratometry versus anterior keratometry on the refractive outcomes of the AT TORBI 709-MP toric intraocular lens
    Antoine Levron
    Hussam El Chehab
    Emilie Agard
    Roman Chudzinski
    Jeremy Billant
    Corinne Dot
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 1199 - 1207
  • [29] Extended depth-of-focus technology in intraocular lenses
    Kohnen, Thomas
    Suryakumar, Rajaraman
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02): : 298 - 304
  • [30] Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation
    Jeon, Sohee
    Choi, Ayoung
    Kwon, Hyunggoo
    PLOS ONE, 2022, 17 (11):